Manuale d’uso / di manutenzione del prodotto COM220 del fabbricante Campbell Hausfeld
Vai alla pagina of 36
COM220 Telephone Modem Revision: 3/07 Copyright © 1997-2007 Campbell Scientific, Inc..
Warranty and Assistance The COM220 TELEPHONE MODEM is warranted by CAMPBELL SCIENTIFIC, INC. to be free from de fects in m aterials and workm anship under normal use and service for t welve (12) months from dat e of shipment unless specified otherwise.
COM220 Telephone Modem Table of Contents PDF viewers note: These page numbers refer to the printed version of this document. Use the Adobe Acrobat® bookmarks tab for links to specific sections. 1. Introduction ........................................
COM220 Telephone Modem Table of Contents D. FCC Warning to Users of Class A Computing Devices .............................. D-1 E. IC Information .......................................................... E-1 List of Figures 1. COM220 DIP Switches...
COM220 Telephone Modem 1. Introduction 1.1 General Description The COM220 modem is a selectable-baud-rate m odem employ ing the Hayes AT comm and set. Its primary use is as a rem ote site phone modem connected to a CSI datalogger. The m odem is powered and enabled by t he battery- powered datalogger.
COM220 Telephone Modem The COM220 is connected to a CSI dat alogger by a 9-pin submini ature D cable. This is the same 9-pin CS I/O interface com mon to all Campbell Scientific datal oggers (except the CR200 series). This is not an R S-232 connection.
COM220 Telephone Modem 2. Specifications • Standards: V.92, K56Flex, V.90, V.34, V.32bis, V32, V23, V22bis, V22, V.21, B212, B103 • Registration: FCC US: 3A4M508BSM 2-T-W IC 2377 A-SM2TW TBR21 •.
COM220 Telephone Modem TABLE 1. Dataloggers that Require Direct 12 VDC Connection to COM220 CR10(X) with silver wi ring panel CR10(X) with black C R10 wiring panel (P/N 8032) 21X(L)—serial number 13,442 or l ower CR500 ⎯ serial num ber 1764 or lower CR7—700X serial num ber 2778 or lower 3.
COM220 Telephone Modem SE 1 2 34 56 78 H 123 4 L DIFF H EX1 HL HL L P2 P1 12V G DC ONLY CAUTION LUG GROUND POWER IN WIRING PANEL CR1000 PERIPHERAL PORT RS-232 (Not Isolated) SN: CS I/O MADE IN USA 11 .
COM220 Telephone Modem CAMPBELL SCIENTIFIC INC. CR10 MADE IN USA WIRING P ANEL NO. EARTH DIFF SE AG H L AG H L AG H L AG G G E3 AG 4 5 6 78 9 1 0 1 1 1 2 GGGG 12V 12V SWITCHED 12V G 12V POWER IN SERIA.
COM220 Telephone Modem You can modify the following COM 220 settings with DIP switches: 1) Comm unication mode (e.g., SDC or M odem Enable) 2) ME baud rate 3) PakBus ready Additional changes (see exam ples below) may be m odified with Hayes AT comm ands.
COM220 Telephone Modem 3) If using a non-PakBus datalogger (e.g., CR 510, CR10X, CR23X, CR7, CR5000), verify that DIP swi tch 1 on the COM220 is in the OPEN (modem enable) position. For PakBus loggers (e.g., CR 800, CR850, CR1000, CR3000, CR10XPB , 23XPB, etc.
COM220 Telephone Modem in Setup’s PakBusPort [LoggerNet, Setup, PakB usPort (in the device map)] may limit the baud rate selected by the modems since it defaults to 9600. You can sometim es achieve a higher connection baud rate by raising the PaKBus Port’s m aximum baud rate.
COM220 Telephone Modem This is a blank page. 10.
Appendix A. Changing COM220 Settings Changing any of the modem's settings m ay result in communication problems. Afte r changing the settings, try the modem locally before installin g it at a remote location.
Appendix A. Changing COM220 Setting s TABLE A-1. Selecting ME Baud-rates via DIP Sw i tche s 3 and 4 ME Baud-rate Switch 3 Switch 4 9600 Open Open 38400 Open Closed 57600 Closed Open 115200 Closed Closed Please note that older dataloggers (e.g. CR10X, C R23X, CR510) can not support the highest COM220 ME baud-rates .
Appendix A. Changing COM220 Setting s FIGURE A-1. COM220 to Computer Conne ction To configure the COM220 with Hayes AT command s, follow these steps: 1) Close DIP Swi tch 8 on the COM 220 (power to t he COM220 must be cycled for ~ 5 sec before c hanges to DIP switch settings are effective).
Appendix A. Changing COM220 Setting s 7) Follow the instructions that appear in the termin al emulator screen (Figure A-3). 8) Be sure to save all new comma nds before exit ing (by enteri ng 5 and enter) . 9) When finished, return DIP switch 8 on the COM220 to its open position.
Appendix A. Changing COM220 Setting s FIGURE A-3. Terminal Emulator Screen in Device Configuration HAYES AT COMMAND SUMMARY: This manual does not attempt to be a primer on the Hayes AT command set. The commands are, therefore , only summar ized below.
Appendix A. Changing COM220 Setting s M0 Speaker always off M1 (default) Speak er on during call establish ment M2 Speak on du ring entire call se ssion S0=0 Disable Auto Answer S0=1 (d efault) Answer o n s econd ri ng S0=2 Answer o n third ring S0=n Answe r on (n + 1) ri ng.
Appendix A. Changing COM220 Setting s FIGURE A-4. Send OS Screen in Device Configuration A.4 Program Examples A.4.1 ModemCallback Example (for CR1000) The ModemCallBack instruction is availab le in the CR1000 with operating system std.1 2 or greater, in t he CR3000 with operating syst em std.
Appendix A. Changing COM220 Setting s ModemCallBack(Resu lt,ComSDC7,9600, 0,"5551212","",40,6 0,Abo rt) CallTable Test5 NextScan End Program A.4.2 DialModem Example (for CR1000) The program below does 2-m inute callbacks via t he COM220 con figured for SDC7.
Appendix A. Changing COM220 Setting s The COM220 can return several possible responses once connected (each terminati ng in a ca rriage return): CAUTION “1” CONNECT “5” CONNECT120 0 “10” C.
Appendix A. Changing COM220 Setting s Do not put Instruction 97 inside a loop or conditional statement; it must be executed ea ch time the table is run. IMPORTANT In the example below, the program does two m inute data callbacks via t he COM220 phone modem.
Appendix A. Changing COM220 Setting s 12: Initiate Telecommunications (P97) 1: 22 Phone Modem/960 0 Baud ;set baud-ra te/m odem 2: 5 Dis abled w h en User F lag 5 is High 3: 45 Seconds Call Tim e Limi.
Appendix A. Changing COM220 Setting s SequentialMode DataTable (TestA,1,-1) DataInterval (0,2,Sec,10) Minimum (1,BatteryVoltage,FP2,0,False) Sample (1,Pan elTemperature,FP2) EndTable DialSequence (409.
Appendix B. CS I/O Connection B.1 CS I/O 9-Pin Connection The pin out of the connector is shown in Fi gure B-1. The direction of the signal relative to the m odem is shown in parenthesis. Unl ess specified otherwise, all le vels are 0 V for logic low, 5 V for logic high.
This is a blank page..
Appendix C. Theory of Operation C.1 Theory of Operation The COM220 modem is used to transmit data over bandwidth-limited chann els such as telephone lines by modulating a udio tones.
This is a bl ank page..
Appendix D. FCC Warning to Users of Class B Computing Devices This equipment generates, uses, and can radiate radio frequency energy , and if not installed and used in accordance w ith the instruction manual, may cause interference to radio communications.
This is a blank page..
Appendix E. IC Information Industry Canada (IC) was form erly known as DOC. NOTE CP-01, Issue 8, Part I Section 14.1 “NOTICE: The Industry Canada la bel identifies certified equipm ent.
This is a blank page..
This is a bl ank page..
Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 Nort h Logan, Utah 84 321 UNITED STATES www.campbellsci.com info@campbellsci.com Campbell Scientific Afri ca Pty. Lt d. (CSAf) PO Box 2450 Somerset West 7129 SOUTH AFRICA www.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Campbell Hausfeld COM220 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Campbell Hausfeld COM220 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Campbell Hausfeld COM220 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Campbell Hausfeld COM220 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Campbell Hausfeld COM220, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Campbell Hausfeld COM220.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Campbell Hausfeld COM220. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Campbell Hausfeld COM220 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.