T ot al Access Rackmount 6-Amp Power Supply Battery Charger Inst allation and Maintenance Practice Document Numbe r: 61 180043L2-5D CLEI: V APUKT0C_ _ June 2005 ®.
Total Access Rackmount 6-Amp Power Supply Batter y Charger Installation and Maintenance Practice ii 61180043L2-5D Front Matter T r ademar ks Any brand names and product names includ ed in this manual are trademarks, registered trademarks, or trade names of their respectiv e holders.
61180043L2-5D iii R e vision Histor y Con v entions The following typographical conventi ons are used in this document: This font indicates a cross-reference link. First-ti me references to tables and figures are shown in this font . This font indicates screen menus, fields, and parameters.
Total Access Rackmount 6-Amp Power Supply Batter y Charger Installation and Maintenance Practice iv 61180043L2-5D T r aining ADTRAN offers training courses on ou r produc ts. These courses includ e overviews on product features and functions while covering applicat ions of ADTRAN’s prod uct lines.
61180043L2-5D v Contents General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Features . . . . . . . . . . . . . . . . . . . . . .
Total Access Rackmount 6-Amp Power Supply Batter y Charger Installation and Maintenance Practice vi 61180043L2-5D Figures Figure 1. Total Access PS/BC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
61180043L2-5D 1 T otal Access Rac kmount 6-Amp P o wer Suppl y Ba tter y Char ger GENER AL This practice is an installation and maintenance guide for the ADTRAN ® Total Access ® Rackmount 6-Amp Po wer Supply Battery Charger (P S/BC). Figure 1 illustrates the PS/BC (P/N 1180043L2 ) right and left side panels.
Total Access Rackmount 6-Amp Power Supply Batter y Charger Installation and Maintenance Practice 2 61180043L2-5D • Fuse protection • Positive ground • Battery Pack mou nting hardware included .
Description 61180043L2-5D 3 Batter y Disconnect Protection Cir cuit During battery operation a prote ction circuit di sconnects bat tery from the main output when battery voltage drops below 39 VDC, preventing over discharge. When AC returns, the main output provides regulated –54 VDC, batteries recharge, and the system returns to normal.
Total Access Rackmount 6-Amp Power Supply Batter y Charger Installation and Maintenance Practice 4 61180043L2-5D LED Indication A set of three PS/BC multi color LEDs provide status for AC, D C, and battery charge condi- tions. See Table 1 for LED descriptions.
Installation 61180043L2-5D 5 INSTALLA TION After unpacking the Total Access PS/BC, inspect it for da mage. If damage has occurred, file a claim with the carrier, then contact ADTRAN Customer Service. Refer to “Appendix A, Warranty” for further informatio n.
Total Access Rackmount 6-Amp Power Supply Batter y Charger Installation and Maintenance Practice 6 61180043L2-5D Mounting the PS/BC The PS/BC housing occupie s a nominal area 15.
Wiring Descriptions 61180043L2-5D 7 Alter nate Mounting Two alternate mounting methods include mounting directly to a wall using c ustomer supplied wood screws, or to a 16-gauge steel bracket (P/N 3265555) that mounts in the cabinet. Bracket mount location is normally at the battery position when batteries are mounted external to the cabinet.
Total Access Rackmount 6-Amp Power Supply Batter y Charger Installation and Maintenance Practice 8 61180043L2-5D DC P o wer Output The 4-foot long, three co nductor PS/BC power outpu t wire originates at the –54V 6A OUTPUT modular connec tor and terminates at three #6 ri ng lugs for customer designated connection.
Operation 61180043L2-5D 9 Batter y Char ge/Discharge CA UTION To prevent battery discharge prior to system operation, do not con- nect the battery to the PS/BC un til the AC power is connected or imminent.
Total Access Rackmount 6-Amp Power Supply Batter y Charger Installation and Maintenance Practice 10 61180043L2-5D SPECIFICA TIONS Power Factor specifications for the Total Access PS/BC are listed in Table 2 . PS/BC specifica- tions are listed in Table 3 .
61180043L2-5D A-1 A ppendix A W ar r anty W AR R ANTY AND CUSTOMER SER VICE ADTRAN will replace or repair this product wit hin the warranty peri od if it does not meet its published specifications or fails while in se rvice. Warr anty information can be fo und at www.
Carrier Networks Division 901 Explorer Blvd. Huntsville, AL 3580 6 ®.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il ADTRAN 6-Amp Power è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del ADTRAN 6-Amp Power - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso ADTRAN 6-Amp Power imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul ADTRAN 6-Amp Power ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il ADTRAN 6-Amp Power, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del ADTRAN 6-Amp Power.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il ADTRAN 6-Amp Power. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo ADTRAN 6-Amp Power insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.