Manuale d’uso / di manutenzione del prodotto Indirect - Fired Water Heater AL SL del fabbricante Burnham
Vai alla pagina of 24
1 INST ALLA TION, OPERA TING AND SER VICE INSTRUCTIONS FOR Alliance SL ™ Indirect - Fired W ater Heater For service or repairs to the water heater , call your heating contractor . When seeking informa- tion on the water heater , provide Model Number and Serial Number as shown on Rating Label.
2 PLEASE READ INSTRUCTIONS CAREFULL Y BEFORE INST ALLING W A TER HEA TER U.S Boiler Company , Inc. – Burnham Hydronics (herein called the Company) intends that this Alliance SL™ Indirect-Fired W ater Heater be used as a separate zone to a heating system boiler .
3 INDEX General Information ..................................................................................................................... 2 Specications & Ratings .........................................................................
4 A. INSPECTING AND PREP ARING THE W A TER HEA TER q AL27SL thru AL70SL - Remove the cardboard box, which comes packaged with the heater . It should contain the following: TPI thermostat, T&P valve and a “T ee”, foamed lid and screws. q AL1 19SL - Remove the cardboard boxes, which come packaged with the heater .
5 valve must be marked with maximum set pressure not to exceed the marked maximum allowable working pressure of the water heater (150psi). Install the valve into the opening provided and marked for th.
6 q Do not apply heat directly to the cold-water inlet as it is made of plastic and will melt. G. BOILER SUPPL Y CONNECTIONS q W ARNING: Boiler temperature must be controlled by the boiler high limit not to exceed 200°. Failure to do so will create a hazardous installation and void the applicable limited warranties.
7 q Run all 24V AC wiring thru the square notch on bottom of TPI case. (See TPI Diagram 3) q Incoming 24V AC power must be connected to 24V AC connectors on the bottom right corner of TPI control.
8 q Do not apply heat to cold inlet. q If there is a check valve (sometimes in water meter), backow preventer or pressure-reducing valve, install an adequate size expansion tank. G. FILLING THE HEA TER q Completely ll heater .
9 W A TER TEMPERA TURE CONTROLS A periodic inspection of the operating controls, heat exchanger and wiring should be made by qualied ser - vice personnel. T emperature of the water should be tested periodically at the faucet to be sure thermostat is working properly .
10 TPI CONTROL - DIAGRAM 1 Indicating Light T emperature Adjust Differential Adjust TPI CONTROL - DIAGRAM 2 Screw A.
1 1 TPI CONTROL - DIAGRAM 3 Outgoing 24V wires to relay or zone valve Incoming 24V power connection Outgoing 1 10V wires to circulator Chase Nipple Conduit Incoming 24V power connections NOTE: Use pro.
12 FIGURE 1 - Installation Using Zone V alves Installation Diagram Using Zone V alves FIGURE 2 - Installation Using Circulator Installation Diagram Using Separate Circulator.
13 FIGURE 3 - Coil Detail & T ightening Sequence Bolt Steel W asher Coil Plate Plastic O-Ring Housing T ank Flange ‘L ’ Nut Small outside O-ring Large inside O-ring Proper T ightening Sequence for T op Mount Coil CAUTION: Does not require excessive force to seal properly .
14 Low V oltage 120 V olts L1 Hot 120 V olts L2 Neutral Circula tor 24v T emperature Differential Pump/TT 24v LED flashing green = calling for heat solid green = at temperature red = error 20° 15° 1.
15 Zone V alve Wiring Diagrams Wiring for 3 W ire Zone V alve L o w V oltage 120 V olts 120v 24v B oiler C onnec tions T 1 T 2 3 H ot N eutr al Z one V alv e 120v 24v T o B oiler C onnec tions /C ir c.
16 Switching relay Wiring Diagrams Switching Relay SR-502 or SR-503 Switching Relay R8845U or SR 501.
17 Switching relay Wiring Diagrams (con’t) Switching Relay SR-504 with Priority Option L o w V oltage 120 V olts FUSE 1 AMP C OM / 24 V A C FOUR Z ONE SWIT CHING REL A Y WITH OPTIONAL PRIORIT Y Z ON.
18 HOW T O OBT AIN SER VICE ASSIST ANCE U.S. Boiler Company , Inc. – Burnham Hydronics does not have a service department or personnel to ser- vice your heater in the eld.
19 Alliance SL™ Indirect-Fired W ater Heater 10/2/1 LIMITED W ARRANTY T en Y ear Limited T ank Replacement W arranty T wo Y ear Limited T ank Replacement Labor Allowance One Y ear Limited Parts W arranty U.
20 ONE (1) YEAR LIMITED P ARTS W ARRANTY DURA TION: The warranty is effective for one (1) year beginning with the date of original purchase. This warranty shall begin from the date of manufacture as indicated by the serial number .
21 MODEL & SERIAL NUMBER INFORMA TION The following information should be noted At time of installation and retained for Future reference. Model No. Serial No. Date Installed Dealer ’s Name Address City State Zip U.S. Boiler Company , Inc., – P .
22 NOTES.
23 NOTES.
24 Optional Lifetime W arranty Registration Card A vailable to Residential, Single Family Homes Only Y es, I wish to purchase the Optional Lifetime W arranty! DA TE ___________________________________.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Burnham Indirect - Fired Water Heater AL SL è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Burnham Indirect - Fired Water Heater AL SL - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Burnham Indirect - Fired Water Heater AL SL imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Burnham Indirect - Fired Water Heater AL SL ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Burnham Indirect - Fired Water Heater AL SL, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Burnham Indirect - Fired Water Heater AL SL.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Burnham Indirect - Fired Water Heater AL SL. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Burnham Indirect - Fired Water Heater AL SL insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.