Manuale d’uso / di manutenzione del prodotto 79A del fabbricante Burnham
Vai alla pagina of 22
1 ® AMERICA’S BOILER COMPAN Y Burnham Corporation Lancaster, PA 17604-307 9 INST ALLA TION, OPERA TING AND SER VICE INSTRUCTIONS ALLIANCE TM SERIES INDIRECT-FIRED W A TER HEA TERS MODELS AL-26A, 40A, 53A, 79A and 1 19A Price - $3.
2 The following defined terms are used throughout this manual to bring attention to the presence of hazards of various risk level s, or to important information concerning the life of the water heater.
3 I. General Information Section I - General Information ............................ 3 Ratings, Capacities, Weights, & Dimensions ....... 4 Section II - Pre-Installation ................................... 5 Section III - Piping .................
4 Table 1: Alliance Water Heater Dimension (Inches) Table 2: Alliance Water Heater Capacities Table 3: Alliance Water Heater Performance AL L I A NCE MO D EL AB C DEFG H I J K AL 26A 4 0 20 - 1/ 4 31 .
5 II. Pre-Installation Inspect shipment carefully for any sign of damage. All equipment is carefully manufactured, inspected and packed. Burnham Corporation's responsibility ceases upon delivery of water heater to the carrier in good condition.
6 Select a circulator which will provide at least the minimum flow rate at combined pressure drop. B . System Zone Control The Alliance TM water heater must be installed as a zone separate from the space heating system.
7 cool to room temperature, or if tank is drained without opening a hot water faucet. A Watts ® Model No. N36 is an appropriate vacuum relief valve. 4. Thermal Expansion Tank If water heater is installed in a closed water supply system, such as one having a back-flow preventer in the cold water line, provide thermal expansion control.
8 III. Piping A. Drain domestic water system. 1. Shut off cold water supply at main shut-off valve. 2. Open one or more system faucets to relieve pressure. Open system drain valve, leaving faucets open to relieve vacuum. 3. Disconnect existing domestic water heating system (if applicable).
9 4. Purge air from domestic water system. Allow water to run so the tank is thoroughly purged of any debris. Run water long enough so that a minimum of five (5) volume changes of the tank are accomplished. Close faucets. Reinstall screens. 5. Check system for leaks.
10 G. Connect water boiler supply piping (See Figures 3 thru 6). 1. For a space heating system that utilizes ZONE VALVES AND A BOILER BYPASS, refer to Figure 3. The Alliance™ connection labeled "BOILER SUPPLY" should be piped to the boiler supply piping as close to the boiler as possible and especially before the bypass piping.
11 3. For a space heating system that utilizes ZONE VALVES WITHOUT A BOILER BYPASS, refer to Figure 5. The Alliance™ connection labeled "BOILER SUPPLY" should be piped to the boiler supply piping after the air purger and before the space heating circulator.
12 H. Connect steam boiler piping (See Figures 7 thru 10). 1. Burnham V-7 Series steam boiler (Refer to Figure 7). a . For satisfactory supply of hot water, the V-7 steam boiler must be equipped with a special tapped rear heater coil cover plate contained in both of the following kits: Part No.
13 Figure 8 Typical Steam Boiler w/Connections Available Below Water Line Figure 9 3. Typical steam boiler with connections available below the water line (Refer to Figure 9). a. The Alliance™ connection labeled "BOILER RETURN" should be piped to a tapping in the boiler that is below the lowest permissible water level.
14 Figure 10 4. Steam boiler without hot water connections available below the water line (Refer to Figure 10). a . Supplying the Alliance™ from the bottom tappings in a steam boiler is not recommended due to insufficient water temperature, especially during warmer months when the space heating system is not operational.
15 IV . Electrical 1. Install electric wiring in accordance with National Electrical Code or the Canadian Electrical Code and local regulations. See Figure 11 for the wiring diagram and the boiler's Installation manual. Figure 11: Priority Wiring Diagram - Multizone Space Heating with Zone Valves or Single Zone Space Heating 2.
16 V . Operation A. System Start-Up 1. Follow boiler installation instructions to place boiler in operation. 2. Turn aquastat dial clockwise to desired setting.
17 VI. Service Instructions A. The Alliance™ is intended to provide a service life of many years. Components that require service, however, may be subject to failure. Failure to use the correct procedures or parts in these circumstances may make the water heater unsafe.
18 VII. T rouble Shooting PROBLEM CAUS E S O LUTI ON N o hot w a t er at f aucet B oiler does not ope rat e R efe r t o boiler i nstall at i on i nstruct i o n s C h e c k ma in ser v ic e s wi tc h C.
19 VIII. Repair Parts 1 A qu ast a t (H one ywel l L 400 6A 2 1 14 ) 801081 2 7 T op Cove r AL2 6 A 804080 8 2 Ha ndh ol e Cove r 805080 2 AL4 0A 3 Ha nd hol e Cov e r Gask et 82 00804 A L53A 4 H and .
20 All Alliance™ Series repair parts may be obtained through your local Burnham Wholesale Distributor. Should you require assistance in locating a Burnham Distributor in your area, or have questions regarding the availability of Burnham products or repair parts, please contact your Burnham Regional Sales Office as listed below.
21 Inspection / Service Schedule DA TE INSPECTION AND/OR SERVICE PERFORMED.
22.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Burnham 79A è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Burnham 79A - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Burnham 79A imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Burnham 79A ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Burnham 79A, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Burnham 79A.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Burnham 79A. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Burnham 79A insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.