OPERA TING & SER VICE MANUAL BUNN-O-MA TIC CORPORA TION POST OFFICE BOX 3227 SPRINGFIELD, ILLINOIS 62708-3227 PHONE: (217) 529-6601 F AX: (217) 529-6644 39064.
Page 2 INTRODUCTION This equipment will brew a half-gallon batch of coffee into an awaiting dispenser . It is only for indoor use on a sturdy counter or shelf.
Page 3 USER NOTICES Carefully read and follow all notices in this manual and on the equipment. All labels on the equipment should be kept in good condition.
Page 4 ELECTRICAL REQUIREMENTS CAUTION - The brewer must be disconnected from the power sour ce until specifi ed in Initial Set-Up. The brewer has an attached cordset and requires 2-wire grounded service rated 120 volts ac, 15 amp, single phase, 60 Hz.
Page 5 TROUBLESHOOTING A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic T echnical Ser vice Department.
Page 6 TROUBLESHOOTING (cont.) PROBLEM Dripping from sprayhead Beverage overfl ows dispenser Weak beverage PROBABLE CAUSE REMEDY 1. Lime Build-up CAUTION - T ank and tank com- ponents should be delimed regularly depending on local water conditions.
Page 7 TROUBLESHOOTING (cont.) PROBLEM Dry coffee grounds remain in the funnel Brewer is making unusal noises PROBABLE CAUSE REMEDY 1. Funnel Loading 1. T ank Heater The BUNN ® paper fi lter must be centered in the funnel and the bed of grounds leveled by gently shaking.
Page 8 FIG. 3 CONTROL THERMOST A T CONTROL THERMOST A T SERVICE This section provides procedures for testing and replacing various major components used in this brewer should service become necessar y . Refer to T roubleshooting for assistance in determining the cause of any problem.
Page 9 Location: The control thermostat is located inside the hood on the left end of the mounting bracket. T est Procedures: 1. Disconnect the brewer from the power sour ce. 2. Locate the black wire on the control thermo- stat. 3. Check voltage across the black wire on the control thermostat and the white wire on the tank heater with a voltmeter .
Page 10 FIG. 6 LIMIT THERMOST A T TERMINALS SERVICE (cont.) LIMIT THERMOST A T Location: The limit thermostat is located inside the hood on the right side of the tank lid. T est Procedures: 1. Disconnect the brewer from the power source. 2. Disconnect the blue/black and black wires from the limit thermostat.
Page 11 SERVICE (cont.) If continuity is present as described, reconnect the wires, the tank heater is operating properly . If continuity is not present as described, replace the tank heater . NOTE- If the tank heater remains unable to heat, remove and inspect heater for cracks in the sheath.
Page 12 L1 BLK T ANK HEA TER WHI LOWER WARMER "KEEP WARM" HEA TER WHI BLK SCHEMA TIC WIRING DIAGRAM VPR, VPR TC & VPR APS GREEN N WHI WHI BLK 33769.0000C 03/06 © 2001 BUNN - O - MA TIC CORPORA TION UPPER WARMER WHI BLK 120 VOL TS A C 2 WIRE SINGLE PHASE 60 HZ WHI/RED VIO LIMIT THERMOST A T BLU/BLK SW .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Bunn VPR APS è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Bunn VPR APS - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Bunn VPR APS imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Bunn VPR APS ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Bunn VPR APS, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Bunn VPR APS.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Bunn VPR APS. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Bunn VPR APS insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.