Manuale d’uso / di manutenzione del prodotto TU3QF-EZ del fabbricante Bunn
Vai alla pagina of 26
BUNN-O-MA TIC CORPORA TION POST OFFICE BOX 3227 SPRINGFIELD, ILLINOIS 62708-3227 PHONE: (217) 529-6601 FAX: (217) 529-6644 www .bunnomatic.com TU3QF - E Z OP E R A TING & S E R V ICE MAN U A L 33030.0000F 8/01 © 2000 Bunn-O-Matic Corporation B U N N ® DISCONTINUED VERSION The inf ormation in this manual is no longer current.
Page 2 CONTENTS User Notices ............................................................. 3 Electrical Requirements ............................................ 4 Plumbing Requirements ........................................... 4 Initial Set-Up ....
Page 3 #00831.0000 #00656.0000 #03408.0000 #03409.0000 USER NOTICES Carefully read and follow all notices on the equipment and in this manual. They were written for your protec- tion. All notices on the equipment should be kept in good condition. Replace any unreadable or damaged labels.
Page 4 ELECTRICAL REQUIREMENTS CAUTION - The brewer must be disconnected from the power sour ce until specified in Initial Set-Up. 120V model brewer requires 2-wire, grounded service rated 120 volts ac, 15 amp, single phase, 60 Hz. Proceed as follows: Electrical Hook-Up CAUTION – Improper electrical installation will damage electronic components.
Page 5 INITIAL SET -UP CAUTION - The brewer must be disconnected from the power sour ce throughout the Initial Set-up , except when specified in the instructions. 1. Insert an empty funnel into the funnel rails. 2. Place an empty container of at least 4 gallons capacity under the funnel.
Page 6 CLEANING CAUTION - CLEAN AND SANITIZE YOUR ICED TEA BREWER DAIL Y 1. Remove and thoroughly clean the entire brew funnel. The funnel tip and screen must be free from any tea particles or residue. Reassemble the funnel. 2. Place the ON/OFF switch in the "OFF" position.
Page 7 TU3QF-EZ ADJUSTMENTS & OPTIONAL SETTINGS P1864 33030 082901 P2174 ADJUSTING BREW VOLUMES IMPORT ANT - T ank must be full and refill solenoid shut off prior to making these adjustments. Sprayhead must be installed while making these adjustments.
Page 8 TROUBLESHOOTING A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic T echnical Service Department.
Page 9 TROUBLESHOOTING (cont.) PROBLEM PROBABLE CAUSE REMEDY BREWING CIRCUIT Brew or sanitize cycle will not start 1. Ready light flashing 2. No water 3. No power or incorrect voltage to the brewer 4. ON/OFF switch not in the "ON" po- sition 5.
Page 10 TROUBLESHOOTING (cont.) PROBLEM PROBABLE CAUSE REMEDY BREWING CIRCUIT (cont.) Set up brewer according to instruc- tions in section Adjustments -Brew Volumes . (See page 7) Using a stop watch or second hand, time the length of the brew cycle. Record this time inside the top lid.
Page 11 TROUBLESHOOTING (cont.) PROBLEM PROBABLE CAUSE REMEDY BREWING CIRCUIT (cont.) Dripping from sprayhead Weak beverage Drip out time too long 1. Lime build up 2. Brew Solenoid Valve 1. Sprayhead 2. Water temperature 3. Funnel loading 1. Funnel Tip Inspect the tank assembly for ex- cessive lime deposits.
Page 12 TROUBLESHOOTING (cont.) PROBLEM PROBABLE CAUSE REMEDY Water does not heat to proper temperature IMPORT ANT : Make sure no tem- perature tests are taken before the ready light is "ON". T ank tempera- ture must be stabilized before read- ings are taken.
Page 13 TROUBLESHOOTING (cont.) PROBLEM PROBABLE CAUSE REMEDY Spitting or excessive steaming Brewer is making unusual noises 1. Lime build up on temperature probe, tank or tank heater 2. T emperature Probe 3. Control Board 1. Plumbing lines 2. W ater supply 3.
Page 14 DIAGNOSTICS Intermittent flashing of the READY indicator indicates that a fault exists. Count the number of flashes between pauses and use this chart as a guide to investigating the fault. FLASHES CAUSE THINGS TO CHECK 1 Reserved for future use.
Page 15 SERVICE This section provides procedures for testing and replacing various major components used in this brewer should ser vice become necessar y .
Page 16 SERVICE (cont.) BREW SOLENOID V AL VE FIG. 2 BREW SOLENOID V AL VE Location: The brew solenoid valve is mounted on the left side in the bottom rear of the brewer. Test Procedures: 1. Disconnect the brewer from the power sour ce. 2. Disconnect the white and white/green wires from the solenoid valve.
Page 17 SERVICE (cont.) COLD WA TER SOLENOID V AL VE (for faucet) 33030 052600 WHI to Power Cord WHI/BLU to Control Board J1-3 FIG. 5 COLD WA TER V AL VE TERMINALS P2154.45 FIG. 4 COLD WA TER SOLENOID V AL VE Location: The cold water solenoid valve for the faucet is lo- cated inside the hood.
Page 18 SERVICE (cont.) F AUCET SWITCH P2150.40 33030 052600 FIG. 6 F AUCET SWITCH P2155 ORA to Control Board J3-1 VIO to Control Board J3-2 YEL to Control Board J3-3 FIG. 7 F AUCET SWITCH TERMINALS Location: The faucet switch is located in the front of the hood, above and to the left of the brew funnel, and to the right of the faucet.
Page 19 SERVICE (cont.) HOT WA TER SOLENOID V AL VE (for faucet) 33030 030101 WHI/VIO to Relay WHI to Power Cord P2156.50 FIG. 9 HOT WA TER V AL VE TERMINALS FIG. 8 HOT WA TER SOLENOID V AL VE Location: The hot water solenoid valve for the faucet is lo- cated inside the hood.
Page 20 SERVICE (cont.) LIMIT THERMOST A T FIG. 10 LIMIT THERMOST A T Location: The limit thermostat is located inside the hood on the tank lid. T est Procedure: 1. Disconnect the brewer from the power sour ce. 2. With a voltmeter , check the voltage across the blue wire on the limit thermostat and the white wire on the tank heater terminal.
Page 21 SERVICE (cont.) ON/OFF SWITCH FIG. 12 ON/OFF SWITCH P2150.40 Location: The ON/OFF switch is located in the front of the hood, above and to the right of the brew funnel. T est Procedure: 1. Disconnect the brewer from the power sour ce. 2. Remove the black and white/red wires from the switch terminals.
Page 22 SERVICE (cont.) SANITIZE SWITCH P2150.40 33030 052600 FIG. 14 SANITIZE SWITCH FIG. 15 SANITIZE SWITCH TERMINALS P1283 WHI/YEL to Start Switch GRN to Control Board J5-4 Location: The sanitize switch is located in the front of the hood, above and to the left of the brew funnel, and above the faucet switch.
Page 23 FIG. 17 ST ART SWITCH TERMINALS P1283 SERVICE (cont.) ST ART SWITCH FIG. 16 ST ART SWITCH P2150.40 Location: The start switch is located in the front of the hood, above and to the far right of the brew funnel. T est Procedure: 1. Disconnect the brewer from the power sour ce.
Page 24 SERVICE (cont.) T ANK HEA TER FIG. 18 T ANK HEA TER Location: The tank heater is located inside the tank and secured to the tank lid. T est Procedures: 1. Disconnect the brewer from the power supply . 2. With a voltmeter , check the voltage across the black and white wires.
Page 25 SERVICE (cont.) Control Board FIG. 20 CONTROL BOARD P2159.40 Location: The control board is located inside the hood on the right front behind the start switch. T est Procedure: The test procedures for the control board will vary depending upon the problems experienced by the brewer .
Page 26 KEEP WARM HEATER 33031.0000C 10/00 ©2000 BUNN-O-MATIC CORPORATION WATER TANK LEVEL PROBE PNK BLK BLK WHI WHI WHI WHI WHI WHI GRN PNK PNK WHI/BLU WHI/RED WHI/YEL WHI/ORA WHI/GRN WHI WHI WHI-14 TEMPERATURE PROBE GREEN TEA BLACK TEA FAUCET SWITCH READY IND.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Bunn TU3QF-EZ è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Bunn TU3QF-EZ - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Bunn TU3QF-EZ imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Bunn TU3QF-EZ ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Bunn TU3QF-EZ, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Bunn TU3QF-EZ.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Bunn TU3QF-EZ. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Bunn TU3QF-EZ insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.