Manuale d’uso / di manutenzione del prodotto JDF-4S del fabbricante Bunn
Vai alla pagina of 31
JDF-2S JDF-4S Silver Series® INST ALLA TION & OPERA TING GUIDE BUNN-O-MA TIC CORPORA TION POST OFFICE BOX 3227 SPRINGFIELD, ILLINOIS 62708-3227 PHONE: (217) 529-6601 F AX: (217) 529-6644 T o ensu.
2 44744.2 070913 BUNN-O-MA TIC COMMERCIAL PRODUCT WARRANTY Bunn-O-Matic Corp. (“BUNN”) warrants equipment manufactured by it as follows: 1) Airpots, thermal carafes, decanters, GPR servers, iced tea/coffee dispensers, MCP/MCA pod brewers thermal ser vers and Thermofresh servers (mechanical and digital)- 1 year parts and 1 year labor .
3 USER NOTICES Carefully read and follow all notices on the equipment and in this manual. They were written for your protec- tion. All notices are to be kept in good condition. Replace any unreadable or damaged labels. 27442.7000 00986.7000 33461.0001 JDF-2S W ARNING FA ILURE TO COMPL Y RISKS EQUIPMENT DAMAGE, FIRE OR SHOCK HAZARD.
4 PLUMBING REQUIREMENTS This dispenser must be connected to a COLD WA TER system with operating pressure between 20 and 100 psi (138 and 690 kPa). This water source must be capable of producing a minimum flow rate of 3 fluid ounces (88.7 milliliters) per second.
5 2. On Portion Control models, connect membrane switches to Door Circuit Board. 4. Secure the door cover using 5 screws provided. DOOR COVER INST ALLA TION 1. Install door cover by first plugging the door harness connector into the machine harness connector located at the bottom of the machine door .
6 INITIAL FILL CAUTION: The dispenser must be disconnected from the power source throughout the initial fill except when specified in the instructions. 1. Remove drip tray assembly and splash panel from the dispenser . Replace the drip tray . 2. Connect the water source to the back of the dispenser .
7 FIG 5 Initial Fill Connection - JDF-2S 7. T urn ON the refrigeration switch near the main control board (Fig. 7). This will start the water bath pump circulation. 8. Check water level in the overflow tube and top off the tank if necessary (Step 5).
8 OPERA TING CONTROLS FIG 7 Refrigeration Switch FIG 9 Product Dispense Switches - JDF-2S Refrigeration Switch The refrigeration switch is located on the Electrical Panel of the dispenser near the Circuit Board. This switch controls power to the water bath pump and relay contacts for the compressor and condenser fan motor .
9 FIG 11 Product Dispense Switches - JDF-2S Product Dispense Switch (Membrane Switch Machines) A. Product Dispense Switch Momentarily pressing and releasing one of the switches will initiate a timed dispense. Each station has three different timed dispenses which are preset at the factory .
10 OPERA TING CONTROLS (Continued) Portion Control Option (Mechanical Switch Machines) The dispenser is also equipped with a portion control option. The following steps will guide you through the set up process for this option. Portion control can be set on one or all dispense heads as needed.
11 P3585 FIG 15 T emperature LEDs JDF-2S (Early Models) FIG 16 T emperature LEDs JDF-4S P3845 OPERA TING CONTROLS (Continued) FIG 15A T emperature LEDs JDF-2S (Late Models) Procedure to return all dispense heads back to Push and Hold mode (Mechanical Switch Machines): 1.
12 CLEANING & PREVENTIVE MAINTENANCE Daily: Rinse Procedure T ools required: 32 oz. (946 ml) minimum empty container 1. Open dispenser door . Lift up on product containers and remove them from the machine. 2. Close the door , place an empty container under the dispensing nozzle.
13 CLEANING (cont) Monthly: Clean Condenser Coils and Filter 1. Removable filter can be cleaned in warm soapy water . 2. Use a soft bristle brush to clean the build up of dirt in the condenser . Annually: Check water level in ice bath. T op off if needed.
14 FIG 17 Adjusting Water Flow Using 1/4" allen wrench Mix Ratio Adjust water flow rate to: Product Brix % (water + concentrate) 2+1 *3.0 fl. oz (89 ml) Prune Juice 16.0% per 3-second test Other * Orange Juice 11.8% 4+1 Pineapple Juice 12.8% Cranberry Fruit Cocktail 14.
15 LOADING Frozen Concentrates 1. Thaw the frozen concentrate in a refrigerated 35-40 degrees F (1.6-4.4 degrees C) environment for 36 to 48 hours before use. NOTE: Loading frozen concentrate in the product cabinet may cause damage to the machine. This damage is not covered by warranty .
16 T otal Dispense Ratio Set Up Procedure 1. Adjust water flow as described in W ater Flow T esting and Adjustment . Record water output setting for later reference on each dispense head. Suggested target is 3 ounces. 2. Place the Program switch in the ON position.
17 T emperature Compensated Refractometer Method 1. Adjust the water flow as described in Water Flow T esting and Adjustment. 2. Place an empty container under the appropriate dispense nozzle. 3. Press and hold the “Product Dispense Switch” Figs 9 & 10, until water and concentrate begin flowing freely from the dispense nozzle.
18 FUNCTION LIST P3585 FIG 18 JDF-2S (Early Models) 1 3 5 2 4 44744.2 110813 Circuit Board LED Indicators - JDF-2S (Early Models) LED # LED Color Illuminates: 1 Green When the compressor should be ON. 2 Cabinet Red When the cabinet temperature is above 50 degrees F .
19 FIG 19 JDF-4S FUNCTION LIST (Continued) 3 1 2 4 5 P3845 Circuit Board LED Indicators - JDF-4S and Late Model JDF-2S LED # LED Color Illuminates: 1 Bath Red When bath temperature is above 34 degrees F . Flashes slowly when compressor is in a 6 minute delay period.
20 TROUBLESHOOTING A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic T echnical Ser vice Department.
21 TROUBLESHOOTING (cont.) Check for "ON" position or no con- tinuity - replace switch. Clean filter and fins or replace con- denser filter . (Filter not supplied on some machines). A) Check for 120V or 230V AC. Re- place fan motor or check fan blades for obstructions.
22 TROUBLESHOOTING (cont.) Dispense station not working All stations dispense concentrate only 1. Dispense Lockout switch set to OFF position. 2. Dispense switch failed Main water supply Frozen bath Inlet water valve failed Place switch in ON position.
23 TROUBLESHOOTING (cont.) Dispense station concentrate only Dispense station water only Replace solenoid (24vdc) or check wire connection between water valve and main control board. Replace refill concentrate container or BIB Check for proper counterclockwise rotation of pump rollers.
24 TROUBLESHOOTING (cont.) Water leak filling drip tray or around dispense deck area Water leaking beneath machine Erratic spray during dispense Dispense nozzle dripping water 1. Initial fill/setup 2. Dispense deck 3. Water pressure greater than 100psi 1.
25 TROUBLESHOOTING (cont.) Unit is not working Difficulty brixing and/or weak bev- erage Difficulty brixing and/or weak bev- erage Difficulty brixing bag-in-box 1. Step-down transformer . 2. Main control board. 1. Product viscosity or too cold. 2. Low water pressure.
26 COOLANT SCHEMA TIC DIAGRAM CONDENSER SUCTION ACCUMULA TO R COMPRESSOR EV APORA TO R PROCESS TUBE FIL TER DRYER 44744.2 062912.
27 J6-1 J11-1 J11-5 J6-1 J6-5 J6-3 J5-1 J5-4 J2-1 J2-6 GRN WHI/ORN LEFT DISPENSE RIGHT DISPENSE LEFT DISPENSE RIGHT DISPENSE YEL YEL WHI/VIO RECIR. PUMP BRN WHI BLK J1-1 J1-5 WHI J3-1 J3-2 WHI/BLK ORN.
28 SCHEMA TIC WIRING DIAGRAM JDF-2S 44744.2 030813 J6-1 J11-1 J11-5 J6-1 J6-5 J6-3 J5-1 J5-4 J2-1 J2-6 GRN WHI/ORN LEFT DISPENSE RIGHT DISPENSE LEFT DISPENSE RIGHT DISPENSE YEL YEL WHI/VIO RECIR.
29 J6-1 J6-3 J5-1 J5-4 J2-1 J2-6 GRN WHI/ORN STA TION 1 DISPENSE STA TION 2 DISPENSE STA TION 1 DISPENSE STA TION 2 DISPENSE YEL YEL WHI/VIO RECIR. PUMP BRN WHI BLK J1-1 J1-5 WHI J3-1 J3-2 WHI/BLK ORN.
30 SCHEMA TIC WIRING DIAGRAM JDF-4S 44744.2 030813 J6-1 J6-3 J5-1 J5-4 J2-1 J2-6 GRN WHI/ORN STA TION 1 DISPENSE STA TION 2 DISPENSE STA TION 1 DISPENSE STA TION 2 DISPENSE YEL YEL WHI/VIO RECIR.
31 1. Install door cover by first plugging the door harness connector into the machine harness connector located at the bottom of the machine door . 2. Install door cover . 3. Secure the door cover using 5 screws provided. 4. Place refrigeration switch in the OFF po- sition.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Bunn JDF-4S è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Bunn JDF-4S - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Bunn JDF-4S imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Bunn JDF-4S ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Bunn JDF-4S, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Bunn JDF-4S.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Bunn JDF-4S. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Bunn JDF-4S insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.