NOTE: Read the entire instruction in manual applicable to specific unit before starting the installation. This symbol → indicates a change since the last issue.
I. INSPECT PACKAGE AND CHECK EQUIPMENT Inspect contents of packaged humidifier. File claim with shipping company prior to installation if shipment is damaged or incom- plete. The package should contain: 1. Humidifier and media assembly 2. Humidistat 3.
VI. INSTALL DRAIN LINE 1. Use 1/2- or 5/8-in. vinyl tubing (field supplied) to connect drain on bottom of humidifier housing to an open drain. 2. Use supplied worm clamp to hold drain tubing in position over drain fitting outlet. CAUTION: Unit may leak if drain tubing is misapplied.
II. SELECT LOCATION (SEE FIG. 5.) Humidifier must be installed on supply plenum only. If furnace has air conditioning coil, be sure humidifier does not interfere with coil ends. Remember to provide clearance for maintenance and evaporator pad removal.
INSTALLATION OF HUMBBSFP1016-A-- FAN POWERED HUMIDIFIER Bryant’s HUMBBSFP1016-A-- fan powered humidifier can only be installed on the supply plenum of a forced-air system. This unit requires an external 115-vac (fused) plug-in receptacle near the equipment for proper operation.
IV. MOUNT THE HUMIDIFIER 1. Attach foam tape to back of mounting flange (exclude the off-set edge). 2. Hook off-set edge over opening cut in plenum. 3. Place humidifier in plenum aligning screw holes with flange. 4. Align, level, and tighten all screws for air tight seal.
INSTALLATION OF HUMBBSBP2017-A-- BYPASS HUMIDIFIER Bryant’s HUMBBSBP2017-A-- bypass humidifier can be installed on either the supply or return plenum of a forced air system. This unit requires an external bypass duct between the supply- and return-air ductwork.
5. Attach transfer tube to solenoid valve and insert free end into inlet fitting on top of unit housing. 6. Attach bridge rectifier to solenoid valve. 7. Insert sheet metal screws into lower holes in plenum, pre-drilled using template. 8. Tighten screws until heads protrude approximately 3/16-in.
II. SELECT LOCATION (SEE FIG. 14.) Humidifier may be installed on either supply or return plenum. If furnace has air conditioning coil, be sure humidifier does not interfere with coil ends. Remember to provide clearance for maintenance and evaporator pad removal.
VIII. INSTALL HUMIDISTAT AND COMPLETE WIRING 1. Mount humidistat on inside wall or return-air duct in accordance with section INSTALLATION OF HUMIDIS- TAT on page 10. NOTE: Wiring must comply with national electrical code and any local codes or ordinances that may apply.
II. DUCT MOUNTING (LOW VOLTAGE) 1. Locate humidistat at least 8 in. upstream of humidifier in return-air duct. If mounting near elbow area, keep device 6 in.
V. OPERATION When relative humidity falls to humidistat set point, the humidistat switch makes contact and starts humidifier. In some central unit humidifier systems, furnace fan must be operating before humidi- fier will start. An increase in relative humidity above set point will stop humidifier.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Bryant HUM-56-1 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Bryant HUM-56-1 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Bryant HUM-56-1 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Bryant HUM-56-1 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Bryant HUM-56-1, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Bryant HUM-56-1.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Bryant HUM-56-1. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Bryant HUM-56-1 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.