Keep these instructions with the appliance. Diese Gebrauchsanweisung bitte beim Gerät aufbewahren. Bewaar deze handleiding bij het apparaat. Zachowaj instrukcję urządzenia. Conservate le istruzioni insieme all’apparecchio. Păstraţi maualul de utilizare alături de aparat. Tento návod si odložte so spotrebičom. Хранить руководство вместе с устройством. Φυλάξτε αυτές τις οδηγίες μαζί με τη συσκευή.
For indoor use only. Nur zur Verwendung im Innenbereich. Alleen voor gebruik binnenshuis. Do użytku wewnątrz pomieszczeń. Destinato solo all’uso domestico. Numai pentru uz casnic. Len pre vnútorné použitie. Использовать только в помещениях. Για χρήση μόνο σε εσωτερικό χώρο.

Thank you for purchasing this Hendi appliance. Please read this manual carefully before connecting the appliance in order to prevent damage due to incorrect use. Read the safety regulations in particular very carefully.
Dear Customer,


Grounding installation This appliance is classified as protection class I appliance and must be connected to a protective ground. Grounding reduces the risk of electric shock by providing an escape wire for the electric
current. This appliance is equipped with a cord having a grounding wire with a grounding plug. The plug must be plugged into an outlet that is properly installed and grounded.
Main parts of the appliance Please check the following packing list before installation.

(1) Cover (2) Filter basket (3) Percolator tube (4) Urn body (5) Level indicator (6) Faucet (7) Water tray (8) Indicator lamp (9) Power switch with indicator light

Operation Instruction How to brew coffee by our Percolator? Please operate as the following: 1. Clean the filter basket, cover, percolator tube and the inside of tank with a non-abrasive deter- gent and rinse with clean water. 2. Pour cool water into the urn to bill at least half of total capacity of the urn 3. Centre the Percolator tube (3) into the bottom well of urn body (4), and make sure that it is po- sitioned firmly. 4. Centre the filter basket (2) into the Percolator tube (3) and place the [coarse] grounded coffee in the basket then cover off the urn (1) securely by turning it until it locks into place.
5. Plug the cord into the electric outlet and turn the power switch (9) "ON". Indicator of power switch lights up. 6. When the green indicator lamp (8) lights up, the brewing process is completed. 7. The second heating system will start to operate automatically to keep the coffee warm, coffee now ready to be served. 8. When there are only about 3 cups of coffee left in the urn, please turn the power switch (9)"OFF" and unplug the cord from the electric outlet. 9. Advice: use 500 grams of coarsely ground coffee per 10 litres of water.

Descaling The red indicator light (8) will be illuminated when the boiler gets too hot and needs to be cleaned and/or descaled.
1. Pour the solution in the boiler to maximum the “MAX” level. 2. Wait to allow the solution to loosen the build-up. 3. Rub lightly and gently with a brush with soft bris- tles. 4. Drain off the dirty water. 5. Repeat steps 1~4 until build-up has been re- moved. 6. Use a dry cloth to wipe the solution away. 7. When you drain off dirty water, leave the tap open and rinse the boiler with clean water till taste and smell are completely gone. 8. Now you can use the boiler again.
This appliance should be cleaned and descaled frequently. To keep this appliance in optimum condition and to ensure its operation, it is crucial that you descale the appliance on a regular basis. Depending on the hardness of the water and the frequency of use, you need to repeat the following procedure regularly.
To descale use a descaling agent that is suitable for coffee makers. You can also use pure lemon juice, citric acid or cleaning vinegar as a de-scaling agent. To ensure the proper mixture, read the in- structions supplied with the agent. For pure lemon juice or cleaning vinegar the general mixture ap- plies of 1/3 cleaning vinegar or lemon juice to 2/3 water.
Troubleshooting If the appliance does not function properly, please check the below table for the solution. If you are still unable to solve the problem, please contact the supplier/service provider.

Remark: Technical specification is subjected to change without prior notification.
Warranty Any defect affecting the functionality of the ap- pliance which becomes apparent within one year after purchase will be repaired by free repair or re- placement provided the appliance has been used and maintained in accordance with the instructions and has not been abused or misused in any way. Your statutory rights are not affected. If the appli- ance is claimed under warranty, state where and
when it was purchased and include proof of pur- chase (e.g. receipt).
In line with our policy of continuous product devel- opment we reserve the right to change the product, packaging and documentation specifications with- out notice.
Discarding & Environment When decommissioning the appliance, the prod- uct must not be disposed of with other household waste. Instead, it is your responsibility to dispose to your waste equipment by handing it over to a des- ignated collection point. Failure to follow this rule may be penalized in accordance with applicable regulations on waste disposal. The separate col- lection and recycling of your waste equipment at the time of disposal will help conserve natural re-
sources and ensure that it is recycled in a manner that protects human health and the environment. For more information about where you can drop off your waste for recycling, please contact your local waste collection company. The manufacturers and importers do not take responsibility for recycling, treatment and ecological disposal, either directly or through a public system.
Technical specification
Problemi comuni, cause probabili e soluzioni.
| Problema | Possibile causa | Soluzione | |
|---|---|---|---|
| Neither green light nor red light is illuminated. | No mains power. | Check the electrical connections. | p.7 |
| The red light is illumi- nated. | 1. Boiler has exceeded maximum safety limits. 2. Fuse does not work | 1. Once it has cooled off, the boiler will switch on again automatically. 2. Contact your supplier. | p.7 |
| Green light is not illuminated. | Thermostat does not work. | Contact your supplier. | p.7 |
| Green light is not illuminated. | Heating element does not work. | p.7 |