IT
Yukon logo
Manuale d'uso ufficiale

Yukon Photon XT

32 pagine·1.7 MB·Binocolo·PDF·ENNLJA
Yukon Photon XT
Indice dei contenuti 18 sezioni 41-50 ITALIANO · PACKAGE CONTENTS · DESCRIPTION · FEATURES · … MostraNascondi
Page 1 of the Yukon Photon XT user manual
Pagina 1 · clicca per ingrandire
Pagina 1

RIFLESCOPEPHOTONXT RIFLESCOPEPHOTONXT 4.6x42L/4.6x42S/6.5x50L/6.5x50S 4.6x42L/4.6x42S/6.5x50L/6.5x50S RIFLESCOPEPHOTONXT 4.6x42L/4.6x42S/6.5x50L/6.5x50S

Yukon Photon XT diagram (page 1)
Fig. 1

ENGLISH / FRANÇAIS / DEUTSCH / ESPAÑOL / ITALIANO / РУССКИЙ

Page 2 of the Yukon Photon XT user manual — 41-50 ITALIANO
Pagina 2 · clicca per ingrandire
Pagina 2

Riflescope Photon XT

Viseur Photon XT

Zielfernrohr Photon XT

. 21-30

Yukon Photon XT — 41-50 ITALIANO diagram (page 2)
Fig. 2

Visor Photon XT

. 31-40

41-50 ITALIANO

Cannochiale Photon XT

Прицел Photon XT

Laser aperture

Page 3 of the Yukon Photon XT user manual — FEATURES
Pagina 3 · clicca per ingrandire
Pagina 3

ENGLISH SKU MODEL OPTICAL SPECIFICATIONS Magnification, x Objective lens diameter, mm Field of view, degree / m @100m Eye relief, mm Close-up distance, m Eyepiece dioptre adjustment, D Max. detection range (built-in IR illuminator on), m/yds* ELECTRONIC SPECIFICATIONS Type of array Camera resolution, pixel Resolution, lines/mm

26342 Photon XT 4.6х42 L

26346 Photon XT 4.6х42 S

26344 Photon XT 6.5х50 L

26348 Photon XT 6.5х50 S

PACKAGE CONTENTS

Yukon Photon XT — PACKAGE CONTENTS diagram (page 3)
Fig. 3

4.6 42 4.3 / 7.5 60 10 +/-3 170

4.6 42 4.3 / 7.5 60 10 +/-3 120

6.5 50 3.5 / 6 60 10 +/-3 200

6.5 50 3.5 / 6 60 10 +/-3 150

џ Riflescope Photon XT џ Carrying case џ User manual џ Video cable (optionally) џ Cleaning cloth џ Warranty card For improvement purposes, design of this product is subject to change.

DESCRIPTION

Sensitivity of the device, mW - (wavelength 780 nm, resolution 25 lines per mm) - (wavelength 915 nm, resolution 25 lines per mm)

Photon XT is a digital riflescope designed for the use in the twilight and nighttime. The riflescope is equipped with an electronic reticle featuring a number of shape and colour variants. The riflescope has a built-in laser or LED IR Illuminator with a wavelength of 780nm or 810nm respectively used for operation in total darkness. The riflescopes can be mounted using regular mounting brackets for day sights. Due to the use of the CMOS sensor, the riflescope is suitable for daytime use. The lens cap with an integrated filter reduces image brightness which makes daytime observation more comfortable. The riflescopes Photon are designed for hunting, sports shooting, security, general observation.

Click value (HxV), mm@100m Range of reticle adjustment (H/V), mm@100m DISPLAY Type / Resolution, pixel BUILT-IN IR ILLUMINATOR Type / Wavelength, nm Safety class for laser equipment acc. to IEC 60825-1:2007 Output power for laser radiation, not more than OPERATIONAL SPECIFICATIONS Tube diameter, mm Power supply (Battery type) Operation time with one set of rechargeable batt. (IR off/on), hour Degree of protection, IP code (IEC 60529) Video output Max. shock resistance, Joules Operating temperature Dimensions, mm / inch Approx. weight (with/without batteries), kg // oz

Laser / 780 1 13

LED / 810 n/a n/a

Laser / 780 1 13

LED / 810 n/a n/a

* Max. detection range of an object measuring 1.7x0.5 m in natural night conditions (quarter moon).

FEATURES

30 2-3.3V (2xAA) 5/4 IPX4 NTSC 6000 -15°С…+50 °С / +5 °F …+122°F 398x75x80 / 15.7x2.9x3.1 0.67 / 0.62 // 23.6 / 21.9

30 2-3.3V (2xAA) 5/4 IPX4 NTSC 6000

30 2-3,3V (2xAA) 5/4 IPX4 NTSC 6000 -15°С…+50 °С / +5 °F …+122°F 430x75x80 / 16.9x2.9x3.1 0.72 / 0.68 // 25.4 / 24

30 2-3,3V (2xAA) 5/4 IPX4 NTSC 6000

џ 4.6x/6.5x optical magnification џ 60 mm eye relief џ Built-in IR Illuminator (laser 780nm or LED 810 nm) џ 6 reticle types (3 colours) џ Extended operating time - up to five hours џ Adjustable image brightness џ Possible use of any standard mounts for daylight sights џ Resistant to bright light (suitable for day use) џ Video output for recording video (optionally) џ Lightweight and compact

Show 20 more labels / short text on this page
CMOS 656х492 38 · CMOS 656х492 38 · CMOS 656х492 38 · CMOS 656х492 38 · -5 8·10 · -5 8·10 · -5 8·10 · -5 8·10 · -4 4·10 · -4 4·10 · -4 4·10 · -4 4·10 · 25/25 1500/1500 · 25/25 1500/1500 · 17/17 1020/1020 · 17/17 1020/1020 · LCD / 640x480 · LCD / 640x480 · LCD / 640x480 · LCD / 640x480
Page 4 of the Yukon Photon XT user manual — MOUNTING THE RIFLESCOPE ON WEAPON
Pagina 4 · clicca per ingrandire
Pagina 4

COMPONENTS AND CONTROL ELEMENTS

BATTERY INSTALLATION

Yukon Photon XT — COMPONENTS AND CONTROL ELEMENTS diagram (page 4)
Fig. 4
1. Built-in laser IR Illuminator 2. Battery compartment knob 3. LED indicator 4. Riflescope and built-in IR Illuminator ON/OFF button 5. Eyepiece adjustment ring 6. Controller 7. Video output 8. Weaver rail 9. Objective lens cap 10. Lens focus knob

џ Turn the knob (2) of the battery compartment cover 90°

counterclockwise. џ Remove the cover by raising it by its lug. џ Slide in two АА batteries so that the “+” and “-” match the

polarity on the inner side of the cover; rechargeable AA batteries may be used. џ Close the cover of the battery compartment cover and

Yukon Photon XT — COMPONENTS AND CONTROL ELEMENTS diagram (page 4)
Fig. 5

turn the knob (2) of the cover 90° clockwise. џ Battery charge level is shown on the display (icon ). In case of complete battery discharge, empty battery icon turns red. Colour of the LED indicator changes from green to red.

MOUNTING THE RIFLESCOPE ON WEAPON

џ To ensure precise shooting the sight should be correctly mounted on a rifle. Please follow these steps. џ Install the mounting rings (bought separately) on the riflescope's tube and tighten the screws with the help of a hex-

nut wrench. If the eye relief is not sufficient, you can use mount Yukon SW-30 (#29048). џ Install the riflescope on the rail of your rifle and make sure it is securely fixed. џ The riflescope should be mounted as low as possible without touching either the barrel or the receiver. џ Before tightening the mount rings make sure you have the necessary eye relief that allows you to see a full field of

view.

+

Page 5 of the Yukon Photon XT user manual — STARTING THE SCOPE AND IMAGE SETUP
Pagina 5 · clicca per ingrandire
Pagina 5

STARTING THE SCOPE AND IMAGE SETUP

MENU

џ Open the lens cap (9). џ Short press on the button (4) to turn the riflescope on. The LED diode (3) will light up green. Button (4) works as follows: - Short press: riflescope is on, IR Illuminator is off; - Another short press: riflescope is on, IR Illuminator is on – IR1 (power level I); - Another short press: riflescope is on, IR Illuminator is on – IR2 (power level II); - Another short press: riflescope is on, IR Illuminator is on – IR3 (power level III); - Another short press: riflescope is on, IR Illuminator is off; - Subsequent long press: riflescope is off, IR Illuminator is off.

Menu includes the following options: џ Selection of pre-installed reticle. џ Selection of reticle colour. џ Zeroing the riflescope.

Selection of pre-installed reticle: џ Press and hold down the controller (6) to enter the menu. џ Rotate the controller to select icon . Press the controller to enter the submenu. џ Rotate the controller to select the required reticle (6 types available). Its number is shown on the right of the icon.

Press the controller to confirm your choice. џ To exit the menu, press and hold down the controller for two seconds. Or wait 10 seconds to exit automatically.

џ Rotate the eyepiece adjustment ring (5) to see on the display a sharp image of the reticle. џ Aim at a target 20-30 meters away. џ Rotate the lens focus knob (10) to achieve quality image. џ After this adjustment no further dioptre adjustment should be required, regardless of distance or other factors.

Selection of reticle colour: џ Press and hold down the controller (6) to enter the menu. џ Rotate the controller to select icon . Press the controller to enter the submenu. џ Rotate the controller to select the required reticle colour (white (W), red (R) or green (G)). Press the controller to

Adjust the image with the lens focus knob (10) only. џ Rotate the controller (6) to adjust display brightness (icon ): clockwise – to increase brightness; counterclockwise

confirm your choice. џ To exit the menu, press and hold down the controller for one second. Or wait 10 seconds to exit automatically.

– to decrease brightness. Brightness adjustment range is from 0 to 15. џ In low light conditions or in complete darkness turn on the built-in IR Illuminator (1) by pushing the “IR” (4) button.

Zeroing the riflescope: Bore sighting is a preliminary procedure to achieve proper alignment of the sight with the rifle's bore. џ Mount the rifle with the riflescope installed on a bench rest. џ Aim at a target 100 meters away. џ Setup the riflescope according to the instructions in the section "STARTING THE SCOPE AND IMAGE SETUP”. џ Aim the firearm at the target using the mechanical sight. џ Using live ammunition, take a shot, continually aiming at the same hit point on the target. џ Examine the target and determine if the aiming point coincides with the point of impact. Press and hold down the

Icon IR appears on the screen. IR power level changes as you sequentially press the button (4). Icon appears when you turn off the IR Illuminator. џ The built-in IR is not focusable. џ Press and hold down the button (4) to turn off the riflescope.

controller (6) to enter the menu, rotate the controller to select icon .

Page 6 of the Yukon Photon XT user manual — TROUBLESHOOTING
Pagina 6 · clicca per ingrandire
Pagina 6

Next to the icon horizontal arrows appear, in the top right corner - location of the reticle along the X coordinate (see

ACCESSORIES

pic.3). Rotate the controller to move the reticle until it matches the point of impact. First press of the controller enables vertical movement of the reticle (axis X appears on the

The riflescope is fitted out with an additional Weaver rail (8) which allows you to attach accessories like: џ IR Illuminators Pulsar-805/Pulsar-940/Pulsar- X850 (#79071/79076/79074) џ Laser IR Illuminators Pulsar L-808S/Pulsar L-915 (#79072/79075)

X=+10

data panel), second press enables horizontal movement (icon Y). Initial position of the reticle is in the centre of the display (coordinates X=0; Y=0). The field of view shows positive and negative numbers which indicate movement relative to the coordinates “X=0; Y=0”. Travel range of the reticle is +/-30 clicks horizontally and vertically. Hold down the controller to save zeroing settings and to exit zeroing mode. Take another shot - the point of impact should now coincide with the aiming point. The scope should now be zeroed-in for the specified distance.

MAINTENANCE AND STORAGE

Pic.3

џ The riflescope features IPX4 degree of protection (protected against splash water) but cannot be submerged in

water. џ Attempts to disassemble or repair the scope will void the warranty! џ Clean the scope's optical surfaces only if necessary, and use caution. First, remove (by blowing with a blower

brush or canned air) any dust or sand particles. Then proceed to clean by using camera/lens cleaning equipment approved for use with multicoated lenses. Do not pour the solution directly onto the lens! џ The riflescope can be used in operating temperatures ranging from -15 °C...+50 °C. However, if it has been

brought indoors from cold temperatures, do not turn it on for 2 to 3 hours. This will prevent external optical surfaces from fogging. џ Always store the unit in its carrying case in a dry, well-ventilated space. For prolonged storage, remove the

VIDEO OUTPUT

The riflescope is equipped with a video output (7) designed to connect external recording devices and to transmit video signal to monitors, TV sets etc. џ Use the supplied cable to connect an external signal receiver to the video output (7). џ Turn on the scope – image will appear on the external device. Please make sure the external device is in the AV

batteries.

TROUBLESHOOTING

mode. To record video, you can use video recorders such as Yukon MPR (#27041) / CVR640 (#17044) and others.

Listed below are some potential problems that may occur when using the scope. Carry out the recommended checks and troubleshooting steps in the order listed. Please note that the table does not list all of the possible problems. If the problem experienced with the scope is not listed, or if the suggested action meant to correct it does not resolve the problem, please contact the manufacturer.

◄► ►

Page 7 of the Yukon Photon XT user manual — PROBLEM
Pagina 7 · clicca per ingrandire
Pagina 7

PROBLEM

POSSIBLE CAUSE

CORRECTIVE ACTION

PECULIARITIES OF CMOS ARRAY

The riflescope will not turn on.

Batteries have been wrongly installed.

Reinstall the batteries with the correct polarity orientation.

CMOS arrays employed in Yukon digital night vision devices, feature high quality. However certain pixels (or groups of pixels) with increased luminosity (lighter or darker) are allowed. Presence of light and dark pixels and other minor defects of a CMOS array (up to 4%) are acceptable in accordance with regulations of the array producer. Visibility on the screen of light pixels also depends on the type of CMOS array, type of camera and device heating during its operation.

Oxidized contact points in the battery compartment due to “leaky” batteries or contact points becoming exposed to a chemically-reactive solution.

Clean the battery compartment, focusing on the contacts.

The batteries are fully exhausted or one or both batteries are faulty. Low brightness settings.

Install fresh batteries.

The image is too dark.

Adjust image brightness by rotating the controller (6).

Make sure the lenses are not misted or dirty.

Clean the lenses with a cloth wetted in spirit.

Poor image quality.

Check that the eyepiece and lens are adjusted in accordance with the user manual.

Adjust in accordance with the user manual.

Presence of dots is caused by CMOS chip production technology and is not a defect.

There are several light or black dots (pixels) on the display of the device.

Barely visible texture which does not impact detection range and efficiency of observation can be noticed on the display after the built- in laser IR Illuminator is activated.

This is normal for eye safe laser illuminators.

When conducting observation at elevated illumination level (in the daytime) image may flicker.

This peculiarity of day use of the digital riflescope is not a defect.

To reduce image brightness in the daytime, please use the riflescope with the lens cap closed.

Fai una domanda su Yukon Photon XT

I possessori del prodotto e il nostro team di solito rispondono entro 24 ore, e la tua domanda sarà utile anche ad altri.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Nessuna domanda ancora per il dispositivo Yukon Photon XT

Invia la prima domanda: risponderanno altri possessori o il nostro team.

Documento originale

Yukon Photon XT manuale in PDF

32 pagine·1.7 MB·Binocolo·PDF
Clicca su qualsiasi pagina in alto per aprirla qui
Pagina 1 / …
100%
Caricamento pagine…