Manuale d’uso / di manutenzione del prodotto U130T*FRN del fabbricante Bradford-White Corp
Vai alla pagina of 28
(To be performed ONLY by qualified service providers) Save this manual for f utu re r eference Manual 47132A The Bradford White R U150L*FRN U1504S*FRN U430T*FRN U440T*FRN U4403S*FRN U4503*FRN U1XR403S*FRN ( *) Denotes Warranty Years.
The Bradford White Ultra Low NOx Gas Water Heaters Page Service Procedure Introduction 3 - - - Gas Control Troubleshooting Chart 5 - - - Tools Required for Service 4 - - - Burner and Inner Door Gasket.
The Bradford White ECO-DEFENDER Safety System The Bradford White ECO-DEFENDER Safety System was designed to resist the ignition of flammable vapors that can occur outside of the water heater.
It is intended for this manual to be used by qualified service personal for the primary purpose of troubleshooting and repair of the Bradford White ECO-DEFENDER Series of water heaters. The Honeywell WV8860Q Gas Control will display error codes in the event of ab normal operation.
Page 5 LED Sta t us Cont r ol St at us Pr obabl e Cause Servi ce Procedu re N on e (LED n ot on or f l ash in g) G a s v al v e is oper at i n g n orm al l y . Pilot fl am e m ay n ot be pres en t . C h eck f or pil ot f lam e t h r ou gh sigh t gl ass an d l ig h t if n ec e s s ar y .
Page 6 LED Sta t us Contr ol St at us Probabl e Cause Ser v i ce Pr oce dur e Fi v e f l ash es an d t h ree secon d pau se. Th e r mo s ta t we ll fa ult. 1. Dam age t o t h e the rm o we ll wi r e . 2. T h erm ow el l sen sor r esi st an ce ou t of ran ge.
Inner Door Removal Procedure Step 1. Rotate the gas control knob to the “OFF” position. Step 2. Remove outer jacket burner access door Step 3. Inner Door Removal. a) Disconnect chamber door temperature sensor wire harness from the gas valve. b) Disconnect resettable thermal switch white wire lead (leading from gas valve).
Installation of Inner Door With Gasket. WARNING Stripped fastener connections may allow for seal breach of inner door. A seal breach may result in a fire or explosion causing property damage, personal injury or death. Do not over tighten screws in steps 8, 10 and 11.
Step 10. Firmly place right side inner door flange against the burner door flange and secure with two ¼” drive screws from step 3e. DO NOT OVER TIGHTEN SCREWS . Step 11. Align right side inner door to combustion chamber and verify the fastener holes of the combustion chamber are aligned with the right side inner door slotted opening.
Step 1. Closed circuit testing is t he preferred method for testing thermopile. Following the lighting instruction label on the heater, proceed to light the pilot and allow to operate for three minutes.
THERMOPILE REPLACEMENT Step 1. Turn off gas supply to water heater. Rotate gas control knob to the “OFF” position. Step 2. Remove outer jacket door. Step 3. Remove right side inner door and burner door per SERVICE PROCEDURE RG-I, steps 3a through 3g.
PILOT/ELECTRODE ASSEMBLY INSPECTION, CLEANING AND REPLACEMENT Step 1. Turn off gas supply to water heater. Rotate gas control knob to the “OFF” position. Step 2. Remove outer jacket door. Step 3. Remove burner and right side of inner door per SERVICE PROCEDURE ED-I, steps 3a through 3g.
IGNITER, ELECTRODE TESTING AND REPLACEMENT With the pilot not in operation (no pilot flame) you can check the igniter and electrode circuit by viewing pilot thru the sight glass located on the inner door and observing the spark action. SERVICE PROCEDURE ED -IV Igniter and Electrode Testing and Replacement Step 1.
Thermal Well Testing Thermal well testing Position gas control knob to the “OFF” position and disconnect thermal well harness from gas control. N Y Using a multi-meter set to the ohms setting, ins.
° F 012345678 9 40 2610 9 25400 24712 2404 5 23399 22771 22 163 21573 21000 20445 50 1990 6 19383 18876 1838 3 17905 17440 16 990 16553 16128 15715 60 1531 4 14925 14548 1418 0 13823 13477 13 140 128.
Gas Control & Thermal Well Removal From Water Heater Step 1. Turn the gas control knob to the “OFF” position. Step 2. Drain heater to a point below the gas control level. Step 3. Turn off gas supply to water heater and disconnect gas piping from gas control.
Gas Control Assembly to Thermal Well Step 6. Reconnect wire harnesses and igniter wire to gas control per the illustration to the left. Step 7. Reconnect gas piping to gas control.
Step 1. Turn the gas control knob to the “OFF” position Step 2. Disconnect the chamber sensor wire harness from the gas valve. Step 3. Remove the chamber door temperature sensor from the right side inner door (Phillips screw driver). Step 4. Make sure that the ring terminal of the chamber door temperature sensor is not touching any surface.
At periodic intervals (not more then 6 months) a visual inspection should be made of the main burner for proper operation and to insure no debris is accumulating. Main burner should light smoothly from pilot and burn with a blue flame with a minimum of yellow tips.
Step 5. Disconnect (unscrew) manifold mount from feed line. Use a stiff brush, compressed air and/or shop vacuum to remove any debris build up from the manifold mount. Step 6. Remove main burner orifice from feed line (3/8" wrench). Inspect and clean if necessary Step 7.
Step 1. Remove outer jacket door. Step 2. Disconnect white wire leads from resettable thermal switch. Step 3. Using a multimeter capable of measuring continuity (Ohms), place one probe of meter on one of the brass connection tabs of the resettable thermal switch, and the remaining probe on the other connection tab.
SERVICE PROCEDURE ED -VII Resettable Thermal Switch Testing and Replacement RESETTABLE THERMAL SWITCH REPLACEMENT Step 1. Rotate gas control knob to the “OFF” position. Step 2. Remove outer jacket door. Step 3. Disconnect wire leads from resettable thermal switch.
SERVICE PROCEDURE ED-VIII ScreenLok Flame Arrestor Cleaning Step 1. Rotate gas control knob to the “OFF” position. Step 2. Remove outer jacket door.
SERVICE PROCEDURE ED-IX Dip Tube and Anode Inspection and Replacement Page 24 Step 1. Rotate gas control knob to the “OFF” position. Step 2. Turn off cold water supply to water heater. Connect hose to drain spigot of water heater and route to an open drain.
Step 1. Turn off water supply to water heater. Rotate gas control knob to the “OFF” position. Step 2. Turn off cold water supply to heater. Connect hose to drain spigot of water heater and route to an open drain. Open a nearby hot water faucet to vent heater for draining.
1 Flue Baffle 2 Hot Water Outlet/Anode 3 Cold Water Inlet Tube 4 T&P Relief Valve 5 Thermal Well 6 Brass Drain Valve 7 Gas Valve 8 Main Burner Orifice 9 Heat Trap Inlet 10 Heat Trap Outlet 11 Oute.
27.
Email parts@bradfordwhite.com techserv@bradfordwhite.com www .bradfordwhite.com.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Bradford-White Corp U130T*FRN è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Bradford-White Corp U130T*FRN - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Bradford-White Corp U130T*FRN imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Bradford-White Corp U130T*FRN ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Bradford-White Corp U130T*FRN, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Bradford-White Corp U130T*FRN.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Bradford-White Corp U130T*FRN. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Bradford-White Corp U130T*FRN insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.