COMPACT

CONDIZIONATORE D’ARIA LOCALE ISTRUZIONI PER INSTALLAZIONE, USO E MANUTENZIONE
LOCAL AIR CONDITIONER INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE
APPAREIL DE CLIMATISATION LOCAL INSTRUCTIONS POUR L’INSTALLATION, L’EMPLOI ET L’ENTRETIEN
RAUMLUFT-KLIMAANLAGE HANDBUCH FÜR INSTALLATION, GEBRAUCH UND WARTUNG
DE
ACONDICIONADOR DE AIRE LOCAL INSTRUCCIONES PARA LA INSTALACIÓN, USO Y MANTENIMIENTO
APARELHO DE AR CONDICIONADO LOCAL MANUAL DE INSTALAÇÃO INSTRUÇÕES DE USO E MANUTENÇÃO
LOKALE AIRCONDITIONER AANWIJZINGEN VOOR DE INSTALLATIE, HET GEBRUIK EN HET ONDERHOUD
ÔÏÐÉÊÏ ÊËÉMÁÔÉÓÔÉÊÏ ÅÃ×ÅÉÑÉÄÉÏ ÏÄÇÃÉÙÍ ÔÏÐÏÈÅÔÇÓÇÓ ÊÁÉ ×ÑÇÓÇÓ
GR




1. El aparato contiene gas R290 (clasificación de inflamabilidad A3) 2. El aparato debe almacenarse en una lugar bien ventilada en el cual la dimensión de la habitación corresponda a las medidas especificadas para el uso del aparato. El aparato debe instalarse, utilizarse y almacenarse en una habitación cuya superficie respete las dimensiones mínimas en la tabla de página 10. Este aparato contiene una cantidad de gas refrigerante R290 igual a la indicada en la etiqueta de datos colocada en el aparato. 3. El aparato puede utilizarse por niños con una edad no inferior a los 8 años y por personas con reducidas capacidades físicas, sensoriales o mentales, o sin experiencia ni el necesario conocimiento, siempre y cuando bajo supervisión o después de que las mismas hayan recibido instrucciones relativas al uso seguro del aparato y a la comprensión de los peligros inherentes. Los niños no deben jugar con el aparato. La limpieza y el mantenimiento que deben efectuarse por el usuario no deben efectuarse por niños sin supervisión (aplicable para los países de la Unión Europea). 4. El aparato puede utilizarse por personas (incluso niños) con reducidas capacidades físicas, sensoriales o mentales, o sin experiencia ni el necesario conocimiento, siempre y cuando bajo supervisión o después de que las mismas hayan recibido instrucciones relativas al uso seguro del aparato por una persona responsable de su seguridad (sólo aplicable para los países fuera de la Unión Europea). 5 En caso de deterioro del cable de alimentación, debe ser sustituido por el fabricante, por el servicio de asistencia técnica o por una persona con cualificación similar, para prevenir cualquier riesgo. 6. Para prevenir cualquier riesgo de electrocución, es indispensable desconectar el enchufe de la toma de corriente antes de que se efectúe cualquiera operación de mantenimiento en el aparato. 7. Para el correcto funcionamiento del aparato, respete las distancias mínimas y las indicaciones indicadas en este manual (vea figura 1). 8. Para la correcta conexión eléctrica del aparato, siga las indicaciones en el párrafo 2.5.
1. O aparelho contém gás R290 (classificação de ignição A3) 2. O aparelho deve ser armazenado num local bem ventilado e dimensionado de acordo com as especificações de utilização do próprio aparelho. O aparelho deve ser instalado, utilizado e conservado num local adequado, cuja superfície respeite as dimensões mínimas indicadas na tabela da página 10. A quantidade de gás refrigerante R290 que este aparelho contém está indicada na placa de identificação aplicada ao corpo do mesmo. 3. O aparelho pode ser utilizado por crianças de idade não inferior a 8 anos e por pessoas com capacidades físicas, sensoriais ou mentais reduzidas, ou sem experiência ou conhecimento suficiente, desde que sob a supervisão de uma pessoa capaz ou depois de terem recebido instruções relativas à utilização segura do aparelho e à compreensão dos perigos inerentes ao mesmo. As crianças não devem brincar com o aparelho. As operações de limpeza e manutenção de responsabilidade do utilizador não devem ser realizadas por crianças não supervisionadas (aplicável somente para os países da União Europeia). 4. O aparelho pode ser utilizado por pessoas (incluindo crianças) com capacidades físicas, sensoriais ou mentais reduzidas, ou sem experiência ou conhecimento suficiente, desde que sob a supervisão de uma pessoa capaz ou depois de terem recebido instruções relativas à utilização segura do aparelho (aplicável somente para os países da União Europeia). 5. Se o cabo de alimentação está estragado, deve ser substituído pelo fabricante ou pelo seu serviço de assistência técnica, ou por uma pessoa com qualificação semelhante, de modo a evitar qualquer tipo de risco. 6. A fim de prevenir os riscos de eletrocussão é obrigatório desconectar a ficha da tomada elétrica antes de executar qualquer operação de manutenção. 7. Para garantir um funcionamento correto do aparelho, respeite as distâncias mínimas e as instruções fornecidas neste manual (veja a Figura 1). 8. Para realizar a ligação elétrica do aparelho, siga as instruções fornecidas no Parágrafo 2.5.

4.1 - CLEANING 26 4.1.a - Cleaning the appliance and the remote control 26 4.1.b - Cleaning the suction filter 27 4.1.c - Recommendations for energy saving 27 4.2 - Maintenance 27 4.2.a - Discharging condensation 28 4.2.b - Error codes 28
DISPOSAL This symbol on the product or its packaging indicates that the appliance cannot be
treated as normal domestic trash, but must be handed in at a collection point for recycling electric and electronic appliances. Your contribution to the correct disposal of this product protects the environment and the health of your fellow men. Health and the environment are endangered by incorrect disposal. Further information about the recycling of this product can be obtained from your local town hall, your refuse collection service, or in the store at which you bought the product. This regulation is valid only in EU member states.


ILLUSTRATIONS The illustrations are grouped on the initial pages of the manual
0.1 - General information First of all, we would like to thank you for choosing our appliance.
0.2 - SYMBOLS The pictograms in the next chapter provide the necessary information for correct, safe use of the machine in a rapid, unmistakable way.
Service Refers to situations in which you should inform the SERVICE department in the company: CUSTOMER TECHNICAL SERVICE.
Index Paragraphs marked with this symbol contain very important information and recommendations, particularly as regards safety. Failure to comply with them may result in: - danger of injury to the operators - loss of the warranty - refusal of liability by the manufacturer.
Raised hand Refers to actions that absolutely must not be performed.
HAZARD Indicates that the appliance uses inflammable refrigerant. If the refrigerant escapes and is exposed to a source of external ignition, there is a fire risk.

Generic danger It informs the personnel concerned that if the operation is not carried out in compliance with the safety regulations, it presents the risk of suffering physical damage.
Do not cover Indicates to the personnel concerned, that it is prohibited to cover the appliance, to prevent over-heating.

WHEN USING ELECTRICAL EQUIPMENT, BASIC SAFETY PRECAUTIONS MUST ALWAYS BE FOLLOWED IN ORDER
AND INJURY, INCLUDING THE FOLLOWING:
To prevent possible damages to the compressor, each start is delayed by 3 minutes with respect to the last switching off.
copied or transferred to third parties without the express authorization of the manufacturer, OLIMPIA SPLENDID. Our machines are subject to change and some parts may appear different from the ones shown here, without this affecting the text of the manual in any way.

room, it is recommended to disconnect the electric power supply in order to prevent accidents.
water or other liquids onto the unit, since they could damage the plastic components or even cause electric shocks.
smoke, abnormal increase in temperature, electrical dispersions, etc.), immediately switch off the appliance and disconnect the plug from the power socket. For repair work contact solely the technical service centres authorised by the manufacturer and ask for original spare parts to be used. Failure to do this can affect the safety of the appliance.
20. Install the appliance according to the manufacturer’s instructions. An incorrect installation can cause damage to people, animals or property for which the manufacturer accepts no responsibility. 21. If the appliance’s plug is incompatible with the socket, have the socket replaced with a suitable one by a qualified technician, who must ascertain that the section of the socket cables is compatible with the power absorbed by the appliance. We do not recommend using adaptors and/or extension cables. If they cannot be avoided, however, they must comply with current safety regulations and their ampacity (A) must not be below the maximum ampacity of the appliance.


52. Do not use tools different from those recommended by the manufacturer for the defrosting process and for the appliance cleaning. 53. The appliance is equipped with a thermal protector which preserves the circuit board in case of over-temperature. If this safety device intervenes, disconnect the plug from the power socket and wait for the appliance to completely cool down (at least 20÷30 minutes) and then reconnect the plug to the power socket and restart the appliance. If the appliance doesn’t restart, disconnect the plug from the power socket and contact an Assistance Centre.

controller.
indicated in this manual. Use different to that specified, could cause serious injuries. THE MANUFACTURER IS NOT LIABLE FOR INJURY/DAMAGE TO PERSONS/OBJECTS DERIVING FROM FAILURE TO COMPLY WITH THE REGULATIONS CONTAINED IN THIS MANUAL.
* Only for version with heat pump

Quantity of R290 gas in Kg
Minimum size of the site
(see data label on the
for use and storage

b) Work procedure Work shall be undertaken under a controlled procedure so as to minimise the risk of a flammable gas or vapour being present while the work is being performed.
c) General work area All maintenance staff and others working in the local area shall be instructed on the nature of work being carried out. Work in confined spaces shall be avoided. The area around the workspace shall be sectioned off. Ensure that the conditions within the area have been made safe by control of flammable material.

d) Checking for presence of refrigerant The area shall be checked with an appropriate refrigerant detector prior to and during work, to ensure the technician is aware of potentially flammable atmospheres. Ensure that the leak detection equipment being used is suitable for use with flammable refrigerants, i.e. non-sparking, adequately sealed or intrinsically safe.
e) Presence of fire extinguisher If any hot work is to be conducted on the refrigeration equipment or any associated parts, appropriate fire extinguishing equipment shall be available at hand. Have a dry powder or CO2 fire extinguisher adjacent to the charging area.
f) No ignition sources No person carrying out work in relation to a refrigeration system which involves exposing any pipe work that contains or has contained flammable refrigerant shall use any sources of ignition in such a manner that it may lead to the risk of fire or explosion. All possible ignition sources, including cigarette smoking, should be kept sufficiently far away from the site of installation, repairing, removing and disposal, during which flammable refrigerant can possibly be released to the surrounding space. Prior to work taking place, the area around the equipment is to be surveyed to make sure that there are no flammable hazards or ignition risks. No Smoking signs shall be displayed.
g) Ventilated area Ensure that the area is in the open or that it is adequately ventilated before breaking into the system or conducting any hot work. A degree of ventilation shall continue during the period that the work is carried out. The ventilation should safely disperse any released refrigerant and preferably expel it externally into the atmosphere.
h) Checks to the refrigeration equipment Where electrical components are being changed, they shall be fit for the purpose and to the correct specification. At all times the manufacturer’s maintenance and service guidelines shall be followed. If in doubt consult the manufacturer’s technical department for assistance. The following checks shall be applied to installations using flammable refrigerants: The charge size is in accordance with the room size within which the refrigerant containing parts are installed; The ventilation machinery and outlets are operating adequately and are not obstructed; If an indirect refrigerating circuit is being used, the secondary circuit shall be checked for the presence of refrigerant; Marking to the equipment continues to be visible and legible. Markings and signs that are illegible shall be corrected; Refrigeration pipe or components are installed in a position where they are unlikely to be exposed to any substance which may corrode refrigerant containing components, unless the components are constructed of materials which are inherently resistant to being corroded or are suitably protected against being so corroded.

i) Checks to electrical devices Repair and maintenance to electrical components shall include initial safety checks and component inspection procedures. If a fault exists that could compromise safety, then no electrical supply shall be connected to the circuit until it is satisfactorily dealt with. If the fault cannot be corrected immediately but it is necessary to continue operation, an adequate temporary solution shall be used. This shall be reported to the owner of the equipment so all parties are advised. Initial safety checks shall include: That capacitors are discharged: this shall be done in a safe manner to avoid possibility of sparking; That there no live electrical components and wiring are exposed while charging, recovering or purging the system; That there is continuity of earth bonding.
disconnected from the equipment being worked upon prior to any removal of sealed covers, etc. If it is absolutely necessary to have an electrical supply to equipment during servicing, then a permanently operating form of leak detection shall be located at the most critical point to warn of a potentially hazardous situation.
b) Particular attention shall be paid to the following to ensure that by working on
electrical components, the casing is not altered in such a way that the level of protection is affected. This shall include damage to cables, excessive number of connections, terminals not made to original specification, damage to seals, incorrect fitting of glands, etc. Ensure that apparatus is mounted securely. Ensure that seals or sealing materials have not degraded such that they no longer serve the purpose of preventing the ingress of flammable atmospheres. Replacement parts shall be in accordance with the manufacturer’s specifications.
The use of silicon sealant may inhibit the effectiveness of some types of
leak detection equipment. Intrinsically safe components do not have to be isolated prior to working on them.
24. Repair to intrinsically safe components Do not apply any permanent inductive or capacitance loads to the circuit without ensuring that this will not exceed the permissible voltage and current permitted for the equipment in use. Intrinsically safe components are the only types that can be worked on while live in the presence of a flammable atmosphere. The test apparatus shall be at the correct rating. Replace components only with parts specified by the manufacturer. Other parts may result in the ignition of refrigerant in the atmosphere from a leak.

27. leak detection methods The following leak detection methods are deemed acceptable for systems containing flammable refrigerants. Electronic leak detectors shall be used to detect flammable refrigerants, but the sensitivity may not be adequate, or may need re-calibration. (Detection equipment shall be calibrated in a refrigerant-free area). Ensure that the detector is not a potential source of ignition and is suitable for the refrigerant used Leak detection equipment shall be set at a percentage of the LFL of the refrigerant and shall be calibrated to the refrigerant employed and the appropriate percentage of gas (25 % maximum) is confirmed. Leak detection fluids are suitable for use with most refrigerants but the use of detergents containing chlorine shall be avoided as the chlorine may react with the refrigerant and corrode the copper pipe-work. If a leak is suspected, all naked flames shall be removed/ extinguished. If a leakage of refrigerant is found which requires brazing, all of the refrigerant shall be recovered from the system, or isolated (by means of shut off valves) in a part of the system remote from the leak. Oxygen free nitrogen (OFN) shall then be purged through the system both before and during the brazing process.

29. Charging procedures In addition to conventional charging procedures, the following requirements shall be followed. Ensure that contamination of different refrigerants does not occur when using charging equipment. Hoses or lines shall be as short as possible to minimise the amount of refrigerant contained in them. Cylinders shall be kept upright. Ensure that the refrigeration system is earthed prior to charging the system with refrigerant. Label the system when charging is complete (if not already). Extreme care shall be taken not to overfill the refrigeration system. Prior to recharging the system it shall be pressure tested with OFN. The system shall be leak tested on completion of charging but prior to commissioning. A follow up leak test shall be carried out prior to leaving the site.
a) Become familiar with the equipment and its operation.
b) Isolate system electrically.
c) Before attempting the procedure ensure that:
d) Pump down refrigerant system, if possible.
e) If a vacuum is not possible, make a manifold so that refrigerant can be
removed from various parts of the system.
f) Make sure that cylinder is situated on the scales before recovery takes
place.
g) Start the recovery machine and operate in accordance with manufacturer’s
instructions. h) Do not overfill cylinders. (No more than 80 % volume liquid charge).
i) Do not exceed the maximum working pressure of the cylinder, even
temporarily.
j) When the cylinders have been filled correctly and the process completed,
make sure that the cylinders and the equipment are removed from site promptly and all isolation valves on the equipment are closed off.
k) Recovered refrigerant shall not be charged into another refrigeration
system unless it has been cleaned and checked.

32. Recovery When removing refrigerant from a system, either for servicing or decommissioning, it is recommended good practice that all refrigerants are removed safely. When transferring refrigerant into cylinders, ensure that only appropriate refrigerant recovery cylinders are employed. Ensure that the correct number of cylinders for holding the total system charge is available. All cylinders to be used are designated for the recovered refrigerant and labelled for that refrigerant (i.e. special cylinders for the recovery of refrigerant). Cylinders shall be complete with pressure relief valve and associated shut-off valves in good working order. Empty recovery cylinders are evacuated and, if possible, cooled before recovery occurs. The recovery equipment shall be in good working order with a set of instructions concerning the equipment that is at hand and shall be suitable for the recovery of flammable refrigerants. In addition, a set of calibrated weighing scales shall be available and in good working order. Hoses shall be complete with leak-free disconnect couplings and in good condition. Before using the recovery machine, check that it is in satisfactory working order, has been properly maintained and that any associated electrical components are sealed to prevent ignition in the event of a refrigerant release. Consult manufacturer if in doubt. The recovered refrigerant shall be returned to the refrigerant supplier in the correct recovery cylinder, and the relevant Waste Transfer Note arranged. Do not mix refrigerants in recovery units and especially not in cylinders. If compressors or compressor oils are to be removed, ensure that they have been evacuated to an acceptable level to make certain that flammable refrigerant does not remain within the lubricant. The evacuation process shall be carried out prior to returning the compressor to the suppliers. Only electric heating to the compressor body shall be employed to accelerate this process. When oil is drained from a system, it shall be carried out safely.

The appliance is packaged singularly in a cardboard packaging. The packaging can be transported by hand by two operators or loaded on a forklift.
Store the packaging singularly; do not stack it.


If it is transported in a horizontal position, wait at least one hour before starting it.
freely.
A failure to respect what follows may cause damages to the appliance.
a. Install the air conditioner on flat and stable surfaces and on the floor. b. Only connect the air conditioner to power sockets equipped
with a ground system. c. Make sure that curtains or other objects do not obstruct the
air suction filters (Fig.7). d. Make sure to keep a minimum distance of 30 cm (Fig.1)
between the air conditioner and the adjacent figures. e. The appliance must always be activated paying attention that there are no obstacles
for air suction and output. f. The air conditioner must not be used in laundries. g. The air conditioner must be installed in a dry place only. h. The air conditioner must not be started in presence of dangerous materials, steams
or liquids. i. Clean the air filters at least once a week.

The air conditioner must be installed in a suitable environment. It is recommended to reduce solar radiation through curtains, Venetian blinds and to keep doors and windows closed.
a. Position the air conditioner in front of a window or French window. b. Position the machine side terminal (2) on the flexible hose (1) as shown by Fig.8. c. Position the terminal (3) on the opposite side of the flexible hose (1) (Fig.8). d. Insert the machine side terminal (2) on the air outlet grid of the appliance (26) as shown in figure 9. e. Position the terminal (3) in such a way as to make air exit to the exterior (Fig.10)
f. If you possess a sliding window (vertical or horizontal) or a shutter, it is possible to use the supplied
“SLIDER KIT” (4) which allows a more efficient installation. For the installation with KIT SLIDER, proceed as shown in figures 11 and 12.
g. Apply the adhesive seal (8) (Fig.12) h. Position the “SLIDER KIT” (4) and adapt it (Fig.12) i. Position the flexible hose (1) and apply the seal (9) (Fig.12)
Extend the pipe only to the necessary extent, so that the air conveyor remains closed between
the fixture shutters.
The air conditioner can also be installed with fixed holes in windows or walls. Air flow must not be obstructed by protective mesh or similar. Any forms of protection must have a total cross-section for air flow of not less than 140 cm2.
a. Position the machine side terminal (2) on the flexible hose (1) as shown by Fig.8.
b. Drill a 127 mm hole in the glass or in the wall at a height above the floor included between 300 and 1200
mm (Fig.13). c. Position the terminal (6) in the wall hole and mark the drilling points. d. Remove the terminal (6) and drill 6 mm holes. e. Insert the supplied wallplugs (10) in the holes. f. Position the terminal (6) in the hole of the wall and fix it with the supplied screws (10).
g. Insert the machine side terminal (2) on the air outlet grid of the appliance (26) as shown in figure 9. h. Connect the other extremity of the flexible hose (1) on the terminal (6) (Fig.14).
i. Insert the flange (7) in the terminal (6) and close the cap (7a) when the appliance is not running (Fig.14).
The appliance is fitted with a power cable with plug. Before connecting the air conditioner ensure that:

Depending on the modality of use of the appliance, it is necessary to connect the condensation discharge pipe.
2.6.a - Use as dehumidifier
For the correct use of the appliance, work as follows (figures 15 and 16): a. Remove the cap (28). b. Insert the supplied pipe (12) in the connector.
Make sure the end of the discharge pipe (12) is positioned on a drain well or in a container. Make sure the pipe (12) is not clogged.
The functioning modes if the air conditioner can be selected both through the remote control and through the control panel located on board of the air conditioner. The reception of the selected function is confirmed by the emission of a “beep” by the buzzer.
D1 SW2 B SW4
S3 S5
SW1 SW3
S4
S1 S2




The remote control supplied with the air conditioner is the tool which allows You to use the appliance in the most comfortable manner.
It should be handled with care and in particular:
3.3.a - Insertion of batteries
The batteries are supplied with the machine. To insert the batteries correctly:
a. Remove the batteries compartment cover (figure 17). b. Insert the batteries into the relevant compartment (figure 17).
Check the polarity indicated on the bottom of the compartment .
c. Close the compartment correctly (figure 18).
3.3.b - Replacement of batteries
The batteries must be replaced when the icon appears on the display.
Always use new batteries. The use of old or different batteries could generate malfunctioning of the remote control.
The remote control uses two dry alkaline 1.5V batteries (AAA.) (Fig.17).

When replacing batteries, replace both and dispose of the dead batteries in the
appropriate collection centres and as required by law.
Do not re-charge or disassemble the batteries. Do not throw the batteries into the fire. They can burn and explode.
If the battery liquid falls onto the skin or clothes, wash well with clean water. Do
not use the remote control with batteries that have leaked. The chemical products contained in the batteries can cause burns or other risks to health.
3.3.c - Location of the remote control
Work as follows in order to use the appliance.
To prevent possible damages to the compressor, each start is delayed by 3 minutes
with respect to the last switching off.
3.4.a - Preliminary operations
appears the icon and the environment temperature in °C.
to those of the electricity distribution network.

3.4.b - Appliance switching on/off
a. The appliance can be switched ON or OFF for short periods by pressing B1 on the remote control or
SW1 on the control panel (if the appliance is switched off for a long period then it should be deactivated by removing the plug from the mains supply. b. The corresponding LED L2 lights up to indicate that the appliance is switched off. c. In this condition, press B1 again on the remote control (or SW1 on the control panel) to restore all the
formerly selected functions.
When the appliance is OFF all the working timers are ‘reset’.
a. When this operating mode is used the appliance has no effect on the temperature or humidity of the en-
vironment, it merely circulates the air.
b. This mode can be selected by pressing B2 or SW2 until the fan only symbol (
) is activated on the remote control and on the control panel display.
c. In this operating mode the internal fan is always on and the required fan speed can be selected at any
time by pressing key B6 (only from the remote control) (symbol 6 on the remote control).
a. In this mode the appliance cools and dehumidifies the environment. This mode can be selected by pressing B2 or SW2 until the cooling only symbol ( ) is activated on the remote control and on the control panel display.
b. The internal fan is always on at automatic speed or (only from the remote control) at the selected speed.
c. The temperature set-point (Tset) can be adjusted from 17°C to 30°C (from 61 F to 86 F if present) in
1°C steps by means of B4/B5 or SW3/SW4, and its value is shown both on remote and local interfaces.
d. Three minutes (maximum) after the activation of this operating mode the compressor starts and the ap-
pliance starts to distribute cold air.
a. This mode can be selected by pressing B2 or SW2 until the dehumidification only symbol ( ) is activated
on the remote control and on the control panel display.
b. This mode is similar to cooling mode, except that:
fan speed selection not active (Set temperature) set equal to “Tamb” (ambient temperature).
c. In dehumidification mode only, the appliance can operate with only the condensate drain pipe connected
(12) and without the flexible air expulsion hose.

a. This mode can be selected by pressing B2 or SW2 until the automatic symbol (AUTO) is displayed on
the remote control.
b. In this mode, the COOLING and FAN functions are selected automatically depending on the continuously
monitored room temperature value to ensure that there is a perfect comfort-level in the conditioned room.
a. This mode can only be selected from the remote control (by pressing B11) and can only be used in con-
junction with cooling and automatic modes.
b. When this mode is enabled, the internal fan is forced to run at automatic speed and the set room temper-
ature is automatically increased by 1°C after 1/2 hour and by another 1°C again after 1/2 hour (starting from function activation and consequent modification of the set temperature).
c. After 7 hours the initial temperature is automatically restored.
d. When the set temperature is modified from the remote control, when the appliance is placed in standby,
or when the power supply is disconnected, the night function is disabled.
e. To deactivate the function press the B11 button again.
a. This mode allows to program the switching on or the switching off of the appliance.
b. The delay time can be set by the remote control.
3.10.a Programmed switching on
Select the operating mode, the desired temperature and the ventilation speed with which the unit will activate automatically as programmed.
a. By pressing B7, set the desired time delay (from 0.5 to 24 hours) after which the unit will switch ON (starting
from timer confirmation). If no button is pressed within 5 seconds the timer setting function will terminate automatically.
b. When the delay time set has elapsed, the unit switches ON with latest selected settings.
c. To cancel the delayed power-on, press button B7 again until a value of 0 is set.
d. When the timer is active, symbol S2 is activated on the machine and symbol 7 on the remote control.
3.10.b Programmed switching off
a. With the unit in any working mode, press B8 to set the desired time delay (from 0.5 to 24 hours) after
which the unit will switch OFF (starting from timer confirmation). Each following B8 key operation increases the delay time value by 1 hour.
b. If no button is pressed within 5 seconds the timer setting function will terminate automatically.
>>>>>

When the delay time set has elapsed, the overall unit switches OFF.
c. To cancel the delayed shutdown, press button B8 again until a value of 0 is set.
d. When the timer is active, symbol S2 is activated on the machine and symbol 8 on the remote control.
On pressing buttons SW3 SW4 simultaneously for 3 seconds you can change the temperature unit of measure indicated on the machine display from CELSIUS (°C) to FAHRENHEIT (F) and vice versa.
In case a black-out occurs, the appliance stores the former function mode and start up again when re-pow- ered by recovering all previous settings.
intervention, always make sure you disconnected the power plug from the power socket.
remove the filter. There is a risk of injury due to the sharp metal edges.
Do not use water to clean the internal parts of the air conditioner. Exposure to water can ruin the isolation, with the risk of electric shocks.
4.1.a - Cleaning the appliance and the remote control
a. Use a dry cloth to clean the appliance and the remote control. b. It is possible to use a cloth moistened with cold water to clean the appliance in case it’s very dirty.
Do not use a chemically treated or antistatic cloth to clean the appliance.
Do not use gasoline, solvent, polish or similar solvents. These products could cause the breakage or deformation of the plastic surface.

4.1.b - Cleaning the suction filter
To ensure the indoor air is filtered correctly and to guarantee that your air conditioner runs efficiently, it is vital to clean the air filters regularly (Fig.20).
After a certain amount of time this important maintenance operation must be carried out. It is indicated when the Fi alarm message appears on the control panel display.
a. Switch off the conditioner and then remove the filters from the conditioner as indicated in figure 20. b. Wash the filter with a water jet aimed at the side opposite the accumulation of dust. c. If the dirt is particularly difficult to remove (such as grease or other types of deposit), first immerge the
filter in a solution of water and a neutral detergent. d. Shake off any water before reinserting the filter.
Provide for the filter (23) replacement if it is damaged.
e. Make sure the filter (23) has dried completely. f. Correctly reposition the filter (23) in its specific seat. g. Suck possible fluff from the grille (Fig. 21).
Do not use the appliance without the filter (23).
4.1.c - RECOMMENDATIONS FOR ENERGY SAVING
Below find simple recommendations for reducing consumption:
If you do not intend to use the appliance for a long period of time, work as follows:
a. Activate the fan only mode for a few hours (approximately 8÷10 hours) to dry the interior of the appliance. b. Stop the air conditioner and disconnect the power supply. c. Clean the air filter. d. Completely discharge condensation. e. Remove the batteries from the remote control.
Checks before resuming use of the air conditioner:
a. Clean the filters after a long period of inactivity of the air conditioner. b. Check that the air outlet or inlet are not obstructed (especially after a long period of inactivity of the air
conditioner).

4.2.a - Discharging condensation
When condensation in the lower tray reaches the predetermined level, the appliance emits beeps.
In this case:
a. Disconnect the plug from the power socket.
b. Carefully move the appliance in position suitable to unload water.
c. Remove the drain cap (24) and the rubber cap (24a) (Fig.22).
Make sure you correctly tightened the drain cap (24) in order to avoid water leak.
d. Make water unload completely. e. Reposition the rubber cap (24a) and screw the drain cap (24) (Fig.23). f. Insert the plug in the power socket.
If the error repeats, please contact an Assistance Centre.
4.2.b - Error codes
During the appliance functioning, a few anomalies which stop its functioning could appear. In these cases, some error codes appear on the control panel.
In these cases:
a. electrically disconnect the appliance b. wait a few minutes c. connect the plug to the power socket d. restart the appliance.
If the inconvenience persists and the error code doesn’t turn off, electrically disconnect the
appliance and refer to an Assistance Centre.
For the technical data, please consult the data plate applied to the product (Fig.2).
* Internal ambient temp. ** Outside ambient temp.

CAUSE
WHAT DO I DO?
Do not try to repair the appliance by yourself.
If the problem has not been solved, please contact your local retailer or the closest assistance service. Supply detailed information about the malfunction and the equipment version.

A1) Electronic card (power) A2) Electronic card (control) B1) Thermostat probe B2) Water level probe B3) Evaporator temperature sensor. F1) Compressor thermal cut-out
RY1) Relays for compressor M1) Compressore M2) Condenser fan M3) Condensation discharge motor Z1) Compressor capacitor Z2) Condenser for capacitor
*5((1 25
32:(5
32:(5%2$5'
A1
B2
P01P02 1
EL 68
A2
RY1
COMP
P1
CN10
RED
BLUE
FAN
M3
COMPRESSOR
M2 ~
BLACK
BLUE
Y/G
M1
BLACK
~
%52:1 %/8(
Z1
Z2
F1
RED
Problemi comuni, cause probabili e soluzioni.
| Problema | Possibile causa | Soluzione | |
|---|---|---|---|
| • The conditioner works only for a short period. | • The temperature set is too close to ambient temperature. • Suction of outside air is obstructed. | p.33 | |
| • The conditioner works but does not refresh the room. | • Window open. • Some source of heat is operating in the room (burner, lamps, etc.) or the room is crowded. • The temperature set is too high. • The power of the conditioner is not suitable for ambient conditions or dimensions. | p.33 | |
| • Water leaks from the conditioner during transport. | • The conditioner has been tilted or laid flat. | p.33 | |
| • The conditioner switches of,f the controls on the remote control and the control panel do not respond and alarm signal “E1” fal shes on the control panel display. | p.33 | ||
| • The conditioner switches of,f the controls on the remote control and the control panel do not respond and alarm signal “P1” fal shes on the control panel display. | • Excessive build-up of water inside the conditioner | p.33 | |
| • In cooling, night-time or automatic mode, minimum speed cannot be selected. | • Ambient temperature too low | p.33 |