Power/Ampere consumption for cooling 1137 W / 5,2A 1325 W / 6,3 A
Air volume (max. speed) 480 m 3/h 480 m 3/h
Dimension 422x443x825 mm (WxDxH) REMARK: 1. Measuring condition for above is as per EN 14511 : DB=35°C , WB=24°C *DB = temperature of dry bulb = room temperature, WB = temperature of wet bulb = relative humidity. 2. Test condition for data in our rating label is as per safety regulation: EN 60335-2-40 3. Current & Fuse : F2L250V or T2L250V 4. The appliance AC 1200E series can be connected only to a supply with system impedance no more than 0.289Ω. In case necessary, please consult your supply authority for system impedance information. " BEFORE USE
PARTS Front (Fig. 5) 1. Control Panel 2. Carrying handle 3. Water tank 4. Caster 5. Air outlet Back (Fig. 6) 6. Air filter 7. Exhaust air outlet 8. Air filter 9. Air inlet 10. Cord storage 11. Air inlet 12. Water stopper / drainage point Accessories (Fig. 7) 13. Exhaust hose. 14. Adaptor - for insertion over hose and into window spacer (or into hole in the wall/window). 15. Cover for adaptor 16. Window spacer - for filling the open window space 17. Window spacer - for filling the open window space 18. Window spacer - for filling the open window space and with hole for connection to exhaust hose. 19. Drain tube for continuous drainage 20. Active carbon filter 21. Remote control
GENERAL SAFETY Only use in the upright position on a flat level surface and at least 36cm from any objects (fig 1 & 4). Do not place objects on the unit or block the air inlet / outlet (fig. 2). Closely supervise any children and pets when the unit is in use. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with appliance.
ELECTRICAL SAFETY For indoor use only. Switch off and unplug when not in use. Do not use in humid or wet environments (Fig 3) Do not pull the unit along by the cord. IF THE SUPPLY CORD IS DAMAGED, IT MUST BE REPLACED BY AN ELECTRICIAN OR SIMILARLY QUALIFIED PERSON, TO AVOID HAZARD.
FOR MAXIMUM EFFICENCY Close doors and windows Keep curtains of blinds closed during the sunniest part of the day Keep filters clean Once room has reached the desired conditions, reduce temperature and ventilation setting

INSTALATION OF THE EXHAUST PIPE The unit is a portable air conditioner that may be moved from room to room. 1. Using the window spacer (fig. 8) Offer window spacer to the window gap and adjust the length as you need. Feed exhaust hose through the window spacer and slide window across so that spacer is held securely. This technique may also be used for sash windows. Note: Take care to maintain protection against intruders 2. Using the adaptor (fig.9, 10) Cut a 152mm diameter hole in the wall or window. Feed exhaust hose through the window or wall and attach the threaded adaptor from the outside as shown. When not in use, plug the hole with the cover provided. MOUNTING OF THE EXHAUST PIPE (Fig. 11 – 14) Use only the hose provided and clip exhaust hose and unit adaptor to the back of the air conditioner Avoid kinks and bends in the exhaust hose as this will cause expelled moist air to build up causing the unit to overheat and shut down. Fig 11 & 12 show correct position The hose may be extended from 300mm to 1500mm but for maximum efficiency use the shortest length possible. WARNING! The length of the exhaust pipe is specially designed according to the specification of this product. Do not replace or prolong it with your own private hose as this could cause the unit to mal-function. Instalation of the carbon filter (fig. 15,16) 1. Remove the filter frame from the unit. 2. Separate the filter fixer from the filter frame. 3. Remove the active carbon filter from its plastic bag. 4. Insert the active carbon filter into the filter frame. 5. Fix the filter by reassembling the fixer onto the filter frame. 6. Re-fit the filter frame inside the unit. OPERATION Control Panel (Fig. 17) 1. ON/OFF button 2. MODE button 3. TEMPERATURE UP button 4. TEMPERATURE DOWN button 5. SPEED (ventilation) button 6. TIMTER button 7. SLEEP button 8. IONIZER button (optional) a. Display window b. Heating operation indicator (optional) c. Automatic mode indicator d. Cooling operation indicator e. Fan operation indicator f. High ventilation indicator g. Medium ventilation indicator h. Low ventilation indicator i. Receiver for remote control j. Timer operation indicator k. Sleep function operation indicator l. IONIZER operation indicator (optional) m. “Water Full” indicator Turning ON/OFF Press ON/OFF button, the unit will work in cool mode with low fan speed, the pre-setting temperature is 24°C.
Indicators of the functions in progress come on at the same time. *NOTE! The display window shows the ambient room temperature from 0oC to 50oC To turn the unit off, press ON/OFF button again. Setting mode/function Press MODE button to select required working mode: cooling, fan or heating, (Heating is only available for heating & cooling models.) Sign of your selected mode comes on. Setting temperature 1. Press 'Temperature up' or 'Temperature down' button to regulate the temperature you desired. 2. The display window will show the temperature you set as you press 'Temperature up' or 'Temperature down' button. Otherwise, it will always show the ambient temperature. 3. The pre-setting temperature of this machine is: 24oC for cooling, 20oC for heating. Setting ventilation speed Press SPEED button to choose the ventilation speed you need, high or low. The sign of high or low ventilation will light on at the same time. Setting timer 1. Press TIMER button to set the operating hours you desired (1 to 24 hours, the sign of timer will light on). When the set time has been reached, the machine will turn off automatically. The display window will show the hour(s) you set as you press TIMER button. If the timer button is not pressed, the unit will work continuously. 2. By pressing the timer but without turning on the other functions, you can PRE-SET the time for the machine to work. For example, if you press the timer to '2', the unit will work automatically after 2 hours. Sleep function 1. In cooling mode, by pressing the SLEEP button, the set temperature will increase 1oC at the 1st hour, another 1 oC at the second hour, then keeps at that temperature. 2. In heat mode, by pressing the SLEEP button, the set temperature will descend 1oC at the 1st hour, another 1 oC at the second hour, then keeps at that temperature. 3. In sleep mode, the ventilation will keep at low speed. Re- press the SLEEP button, the setting temperature and ventilation speed will return to the pre-selected one. 4. The unit will shut down automatically after the SLEEP function running for 12 hours. 5. Please note, the sleep function is not available while the machine is working in ventilation, dehumidification or auto mode. Only available in Cooling or Heating mode. 6. When the machine is in Sleeping function, the Fan Speed would turn to be LOW speed. Ionizer function (optional) This is only for the model with Ionizer function, i.e. model no. with I. To start the ionizer function, please press IONIZER button, this function can push away the dust and large particles in the air. Self-diagnosis This machine is equipped with self-diagnosis function. If something is wrong in the machine, the LCD will show the word “E1” or “E2”. As this time, please call your service centre. All the above functions can also be performed with the supplied remote control. (fig. 18) This remote control requires 2 pcs AAA batteries to operate. EFFICIENCY BOOSTING (fig. 19) This unit is equipped with “energy efficiency boosting” function, by adding the water to the water tank as below, the energy

efficiency can be boosted, save energy for the earth, save money for you. 1. Open the door for the water tank 2. Take out the water tank 3. Unscrew the tap for the tank and fill up the tank with clean water NOTICE: This efficiency feature by adding water is proposed to do after one hour operation. NOTICE ! 1. To prolong the compressor's life, after switch-off of the unit, please wait for 3 minutes (at least) before re-switch. 2. The cooling system will switch off if the ambient temperature is lower than the set one. The ventilation, however, keeps working on the set level. If the ambient temperature rises above the selected level, the cooling will return to work. 3. On the contrary, the heating will switch off if the ambient temperature is higher than the set one (still, the ventilation keeps working on the set level). As the ambient temperature drops below the selected level, the heating will return to work. 4. This machine is equipped with ANTI-FROST function. While using the heating function during low temperature, sometimes the heating will stop for a while in order to melt the frost. As this occurs, just wait for the heating returns to work. DRAINAGE During the process of cooling, some water will be extracted from the air into the unit. If the tank is full, both of the compressor and motor will stop. The “water full” sign will light on, also the machine will beep as reminder. To make the cooling work again, please empty the water by one of the following ways: Fig. 20 1. Turn off the air conditioner and avoid moving it when full. 2. Position a container (a water tray for example) underneath the drain hole. 3. Remove the drain knob & rubber plug from the drain hole and allow the water to drain out. 4. When the container is almost full, replace the rubber plug in the drain hole and empty the water tray. 5. Repeat until the unit is emptied. 6. Replace the rubber plug and tighten the drain knob firmly. 7. Switch on the unit - the full water or compressor operating indicator should not be flashing. If you wish to operate the unit without the need to empty the water tank, please: Fig 21. Remove the drain knob and rubber plug and retain for future use. Connect the drain tube supplied to the water outlet as shown and locate the other end into a drain. Fig. 22. The drain tube may be extended by adding an extension tube and using a suitable connector. Please note (Fig. 23.) 1. The drain must be at or below the outlet level. 2. Flashing comp / ‘full water’ indicator will not function in this mode of drainage. 3. If you want to extend the water tube, you can connect it with another tube (OD: 18mm)
MAINTENANCE Always unplug the air conditioner from the mains before cleaning. To maximize the efficiency of the air conditioner clean regularly. Cleaning the housing Use a soft, damp cloth to wipe the body clean. Never use aggressive chemicals, gasoline, detergents, chemically treated cloths, or other cleansing solutions. These all could possibly hurt the cabinet. Cleaning the filter Use a vacuum cleaner or tap the filter lightly to remove loose dust and dirt from the filters and then rinse thoroughly under running water (no hotter than 40oC). Dry thoroughly before replacing. Notice! Never operate the unit without the filters. End of season storage (fig. 24) Drain any water in the unit before completely operating the unit on ventilation only mode for a few hours, to thoroughly dry the inside. Clean or change the filter Unplug and store the power cord as shown Cover the cord storage Replace in the original carton or cover for storage.

FAULT CHECK LIST The air conditioner does not run Is the air conditioner plugged in? Is there a power failure? Is the comp / ‘full water’ indicator flashing? Is the room temperature below the set temperature? The machine seems to do little Is there direct sunshine? (Please put down the curtain.) Are too many windows or doors open? Are there too many people in the room? Is there something in the room producing lots of heat? The machine seems to do nothing. Is the filter dusty, contaminated? Is the air intake or output blocked up? Is the room temperature below your selected temperature? Too noisy Is the machine positioned unevenly so as to create vibration? Is the floor underneath the machine uneven?
The compressor doesn’t run. Is so, it is possible the overheat protection of the compressor is on. Just wait for the temperature to drop.
I possessori del prodotto e il nostro team di solito rispondono entro 24 ore, e la tua domanda sarà utile anche ad altri.
Invia la prima domanda: risponderanno altri possessori o il nostro team.