Description The Iris chain counter displays the length of chain let out or down, expressed in metres or feet and the speed of the same. Technical data
Power supply from 10 to 30 V DC Current intake min. 5 mA – max 40 mA Protection rating of front cover IP65* Operative temperature 0 / +70 °C (32 / 158 °F) Graphic display 128 x 64 pixels Max. chain length 999 metres – 999 feet Size (mm) 100 x 100 x 32** Weight (g) 160 * excluding cable connection zone - ** without protective cover
CONNECT ONLY TO A DC POWER SUPPLY.


Installing the chain counter (see connection diagram)

ALWAYS DISCONNECT THE BATTERY PRIOR TO INSTALLATION.




For instructions on making electrical connections, see the attached diagram. The wires must have a



PIN SIGNAL 1 + Battery 2 3 - Battery 4 5 6 UP command 7 DOWN command 8 9 10 Magnetic sensor Chain counter and sensor hole

Connections

The chain counter features a graphic display and three keys: (ON), (UP) and (DOWN). There is also a buzzer that indicates the pressing of the keys or attracts the user’s attention in particular conditions (alarm triggering). The ON key switches on the display and enables the other two keys. It must be used to access the parameter setting menus. For selecting the parameters to be modified and to confirm the values set. The display backlight will switch off 30 seconds after the last command given (adjustable default time – see “BkLight Time”). The UP key commands the hoisting of the anchor and the DOWN key casts it. When the key is released, the action is stopped. During parameter setting, the two keys allow the User to move around the menu and vary parameter values. When switched on, the instrument will make a beep and the following page will appear for a few seconds:


Once the initialisation procedure is complete, the main page will appear.
Where: STATUS: indicates the status of the instrument and any failure. SPEED’: indicates the chain speed during hoisting or lowering in meters per minute or feet per minute. COUNT: indicates the measurement of the chain lowered (in metres or feet). MONITORING: indicates the power supply voltage. ICONS: this is the part of the display bearing the icons that indicate the hoisting or casting of the anchor and any failure. When the instrument is turned on for the first time, it will set up as programmed in the factory (see table).


Parameter Default value Up Alarm 3.0 metres Auto Down Off BackLight Time 30 seconds Units of measurement Metres/centimetres Chain Measure 0.0 metres Barbotin Circumference 33 cm Sensor type unknown Keyboard Beep Yes Language Italian Works Hours 0 Rope_Chain Off Chain counter setting menu
Hold down the (ON) key for six seconds to access the instrument setting menu. The following page will appear on the display:
Menu M e a s u r e A l a r m s & F u n c t i o n S e t t i n g s L a n g u a g e S e n s o r C a l i b r a t i o n
Use the (DOWN) and (UP) keys to move around the menu options.
Once you are positioned on the item to be modified press the (ON) key to confirm your choice.
Use the (DOWN) or (UP) keys to move from one parameter to another.
Once one is positioned on the parameter press the (ON) key to enable modification.
According to the type of parameter, using the (DOWN) and (UP) keys it is possible to reduce/increase the value of the same or disable/enable the function.
Once the modification has been performed, press the (ON) key to confirm.
Using the (DOWN) key go to the Exit option and press the (ON) key again to return to the setting menu. The same procedure must be used to return to the main page.


Measure R e s e t M e a s u r e N o U n i t s Fe e t R o p e _ C h a i n O f f E x i t
Use the (DOWN) or (UP) key to move around the parameters.
Rope_Chain It is possible to enable the function and set the value at which the sensor passes from rope to chain. Setting range 0.1 - 25.0 (metres or feet). This value corresponds to the chain length. To obtain this function, install sensor CMCT-01 (optional).
Alarm and functions menu

Alarms & Functi U p A l a r m 3 . 0 A u t o D o w n O f f L o a d D e f a u l t N o E x i t
Use the (DOWN) or (UP) key to move around the parameters.
Up Alarm It is possible to enable the function and establish the height at which the anchor- winch stops; after which it is only possible to give pulsed commands. Settable values: 1.0 - 1.5 - 2.0…5.0 (metres or feet).
Measurement menu


Auto Down Enables the automatic anchor lowering procedure, at the desired height, with the pressing (for at least 3 seconds) of the keys
and . Settable value: 5 - 10 - 15…40 (metres or feet).
Load Default This function allows the User to revert to the original factory default settings, thus erasing all settings memorised. This command must only be used in the event of programming errors.
Settings C o n t r a s t L i g h t B k L i g h t Ti m e 3 0 K e y b . B e e p Ye s E x i t
Use the (DOWN) or (UP) key to move around the parameters.
Contrast By enabling this function it is possible to start the display contrast programming procedure.
Light By enabling this function it is possible to start the display luminous intensity programming procedure.
BackLight Time This function allows the user to set the backlight on time during which the display remains lit after the last command given (default value 30 seconds).
Keyboard Beep This function allows the user to enable or disable the buzzer (emitted each time a key is pressed).
Select with = No = Yes Confirm with
Settings menu


Language L a n g u a g e E n g l i s h E x i t
Use the (DOWN) or (UP) key to move around the parameters.
Language The user may select the display language: Italian, English, French, German, Spanish
Sensor Calibrat S e n s o r D e t e c t . Barb. Circ. 3 3 . 0 E x i t
Use the (DOWN) or (UP) key to move around the parameters.
Sensor Detect This function has the purpose of calibrating the instrument according to the type of sensor installed (Standard or Project). The second screen indicates the time for a sensor period and type.
Sensor Detect. P r e s s U p / D o w n K e y t o r u n t h e m o t o r
Sensor Detect P r e s s U p/ D o w n K e y t o r un t h e m o t o r 0 . 4 0 0 s ec . S e n s or : St d
Sensor Detect P r e s s U p / D o w n K e y t o r u n t h e m o t o r 0 . 4 0 0 s e c . S e n s o r : P r o j .

Once the “Sensor Detection” function has recognised a “Standard” type sensor instead of a “Project” sensor, when the “Sensor Calibrat.” menu is entered again, the menu options will “configure” themselves according to the sensor detected.
Standard and X.. Project series
1000 – 1500 –2000 W Project series sensor menu (magnet and sensor placed
sensor menu (magnet and sensor placed
on barbotin) Sensor Calibrat Barb. Circ. 3 3 . 0 E x i t
on motor) Sensor Calibrat Red. Factor 5 7 . 0 E x i t
Barbotin Circumference In this row the user must enter the circumference of the gipsy (in centimetres or inches). Use the Table 1 provided to calculate the circumference. Settable values: centimetres or inches. Default value, 33 cm.
Reduction Factor In this row the user must enter the reduction factor. See next Table 2 for the correct value to be entered Default value, 57.

Table 1 - Standard and Project X.. series sensor (magnet and sensor placed on barbotin)

(inches) 6 mm 9 34 13 7 mm 6 25 9 6 28 11 7 33* 13 8 mm 8 38 15 5 31 12 10 mm 6 36 14 5 36 14 12 mm 6 43 17 13 mm 6 46 18 14 mm 5 42 16 3/8” BBB 7 38 15 3/8” HT 6 37 14 5/16” HT 7 36 14 1/2” BBB 6 40 16 1/2” HT 5 40 16 * factory setting of instrument
Table 2 - 1000 – 1500 – 2000W Project series sensor (magnet and sensor placed on motor)

Factor 30 1:52 6 8-5/16”HT 30 1:52 5 10 DIN 766 57*
34 1:52 9 6 65 30 1:70 6 8-5/16”HT 43 30 1:70 5 10 DIN 766 43 31 1:70 5 10 ISO-3/8”HT 44 Project 1500
36 1:70 5 12 ISO-13 DIN 766-7/16”HT 51 39 1:75 6 3/8”HT 52 40 1:75 6 3/8”Proof Coil 53 41 1:75 6 10 DIN 766-3/8”BBB 54 44 1:75 7 10 ISO 58 45 1:75 5 14 ISO 60 46 1:75 6 12 ISO-13 DIN 766 61
47 1:75 5 13 DIN 764 63 * factory setting of instrument


Tests S e n s . C h e c k s LCD Test S w. Ve r s i o n 1 . 0 1 W o r k H o u r s 0 E x i t
Use the (DOWN) or (UP) key to move around the parameters.
Sensor Checks The purpose of this function is to check the state of the sensor:
LCD Test This function switches on all the display’s pixels thus making it possible to perform a check on them.
Software Version Indicates the version of the software installed.
Work Hours Indicates the hours of operation of the winch.
Check menu

Measure R e s e t M e a s u r e N o U n i t s F e e t R o p e _ C h a i n O f f E x i t
Standard and X.. Project series
1000 – 1500 –2000 W Project series sensor menu Sensor Calibrat Red. Factor 5 7 . 0 E x i t
sensor menu Sensor Calibrat Barb. Circ. 3 3 . 0 E x i t
Press the (ON) key to activate controls and to switch on the display lighting. The display lighting switches off 30 seconds after the last command given (adjustable default time – see “BkLight Time”). Press key (UP) to control the anchor ascending.
Press key (DOWN) to cast anchor.
When any key is released (UP or DOWN) the corresponding action is stopped.
Measurement reset To reset the measurement count simultaneously press the (ON) and the (UP) keys for at least three seconds. Measurement reset may also be performed in the Measurement menu by selecting “Yes” in the Reset Measure row.
Measure R e s e t M e a s u r e N o U n i t s F e e t R o p e _ C h a i n O f f E x i t
Automatic casting of the anchor This function must be enabled in the Alarms and Functions menu (disabled by default).

Alarms & Functi U p A l a r m 3 . 0 A u t o D o w n O f f L o a d D e f a u l t N o E x i t
Select the row “Auto Down” and set the value at which the anchor must stop. Then press the (ON) and (DOWN) keys for at least three seconds. Once anchor casting has commenced, release the keys. For safety reasons it is however possible to interrupt automatic descent by pressing any instrument key. Troubleshooting

Though UP or DOWN keys are pressed, the instrument doesn't receive any signal from the magnetic sensor for more than 5 seconds.
Check the sensor electric connections. Check if sensor operates properly. If not, replace it. Check the position of sensor and magnet on gipsy and their distance (3 mm). Check the operation of electric installation or anchor windlass.
The instrument’s power supply voltage is lower than 10V.
Verify the battery charge or operation of the electrics system.
Warranty We guarantee our products from manufacturing defects for 2 years from the purchase date (purchase ticket or any other purchase proof will be requested). Guarantee does not include damages and breakage during the transport, damages and breakage due to faulty installation or improper use. Warranty is no longer valid when repairs or servicing have been made by unauthorized people or made with spare parts which are not original. Warranty does not include the complete replacement of the goods and refers exclusively to the replace of faulty pieces and necessary labour. It does not include transfer or transport expenses. The Customer will not ask for expenses refund.
I possessori del prodotto e il nostro team di solito rispondono entro 24 ore, e la tua domanda sarà utile anche ad altri.