RangeXtender RX 30 / RX 51 / RX 52 Laser receiver for all line lasers with RX-READY technology.
A K G
F A
F I

B
E
E
D
M C
D
A Sound ON / OFF B Receiver field for laser beam C Universal mount D Battery compartment E LED’s for laserindication
(RX 30: front / RX 51 / 52: front, side, backside) F ON / OFF switch G LED status indicator H Switch sensivity

short range / long range I Switch tolerance range precision range / free-hand range J LED sensivity:
green = close range up to max. 15 m / red = long range up to max. 50 m K LED tolerance range:
switched off, precision range / red, free-hand range
L Head magnet M Vial

RangeXtender RX 30 RangeXtender RX 51 RangeXtender RX 52



Use the laser receiver RX for levelling over longer distances or when the laser lines are no longer visible. Switch on with button F; control lamp G will light up.
Line lasers: This button switches hand receiver mode on and off. RX 30 / RX 52: This button is used to establish the tolerance range. RX 51: This button is used to adjust the sensivity.
Set the line laser to hand receiver mode. The laser lines will now pulsate with high frequency, making the laser lines darker. The laser receiver can detect these pulsating laser lines up to a maximum distance of 30 m (RX 30) / 50 m (RX 51 / 52). Minimum distance from the laser device about 3 m. Now move the receiver field (B) of the laser receiver through the laser lines upwards and downwards (horizontal laser line) and/or sideways (vertical laser line) until the centre LED lights up. Now mark the horizontal and/or vertical reference dimension.
+ · + · +


Minimum distance from the laser device about 3 m. Pay attention that the laser lines are not reflected by reflective surfaces. Such reflections can lead to false indications. !

Rapid peeping (lower LED)
Continuous tone (middle LED) = mark the reference
slow peeping (upper LED)

Rapid peeping (lower LED)
Continuous tone (middle LED) = mark the reference
slow peeping (upper LED)

The light intensity of the laser lines is greatest at the centre and diminishes toward the ends. This can reduce the maximum reception range of the laser receiver. !

Used with levelling staff The laser receiver RX can be fitted on measuring staffs with the universal mount. The Flexi measuring staff (Art. No. 080.50) is always recommended when measuring from floor heights. It also allows you to determine heights directly without any need for calculation.

EU directives and disposal This device complies with all necessary standards for the free movement of goods within the EU. This product is an electric device and must be collected separately for disposal according to the European Directive on waste electrical and electronic equipment. Further safety and supplementary notices at: www.laserliner.com/info