IT
Kettler logo
Manuale d'uso ufficiale

Kettler CTR1 - 07858-600

100 pagine·12.1 MB·Cyclette da casa·PDF·ENJA
Kettler CTR1 - 07858-600
Indice dei contenuti 66 sezioni Table of contents · Training 24 · Glossary 32 · Safety Instructions · … MostraNascondi
Table of contentsp.1Training 24p.1Glossary 32p.1Safety Instructionsp.1Short descriptionp.2Pulse measurement with chest strapp.2SD4 / SD8 / SD5 / SD9 / SDCp.2SD7 / SDE / SDBp.2Anzeigebereichp.2Short instructionp.3Function sectionp.3SET (press shortly)p.3SET (press longer)p.3Resetp.3Programp.3Minus – / Plus + keysp.3Pulse measurementp.3Display section / displayp.4Programs: Count up / Count downp.4Programsp.4Pulse-controlled programs: HRC1/HRC2p.4Interfacep.4Display valuesp.4–1 ( RPM )p.4Energy consumptionp.6Dimension settablep.6Value 0 – 9999p.6Text and value display Profilep.6Quick start (to become acquainted)p.6Start of training:p.6End of trainingp.6Snooze modep.6Trainingp.71. Training by power defaultsp.72. Training by pulse defaultsp.7Readiness for trainingp.8Program switchover time / distancep.9orp.10Initial powerp.10Training functionsp.10Change of power profilesp.11Change from speed-independent to speeddependent operationp.11Interruption or end of trainingp.11Resumption of trainingp.11RECOVERY – Functionp.12Recovery pulse measurementp.12*Comment: appears only if the target pulse was achieved once }p.12Individual settingsp.13Or:p.13=>p.14General notesp.14System soundsp.14Speed-dependent operation (running ergometer)p.14Average value calculationp.14Notes on pulse measurementp.14Grade (F) = 6.0 – ( 10 x (P1–P2) )p.14P1p.14Switchover time/distancep.14Profile display during trainingp.14Speed-independent operationp.14Arrows up/down (Speed-independent operation)p.14Training instructionsp.15Warm-upp.15Cool-downp.15Glossaryp.15Scope of loadp.15
Page 1 of the Kettler CTR1 - 07858-600 user manual — Indice dei contenuti
Pagina 1 · Indice
Indice

Indice

Table of contentsp.1Training 24p.1Glossary 32p.1Safety Instructionsp.1Short descriptionp.2Pulse measurement with chest strapp.2SD4 / SD8 / SD5 / SD9 / SDCp.2SD7 / SDE / SDBp.2Anzeigebereichp.2Short instructionp.3Function sectionp.3SET (press shortly)p.3SET (press longer)p.3Resetp.3Programp.3Minus – / Plus + keysp.3Pulse measurementp.3Display section / displayp.4Programs: Count up / Count downp.4Programsp.4Pulse-controlled programs: HRC1/HRC2p.4Interfacep.4Display valuesp.4–1 ( RPM )p.4Energy consumptionp.6Dimension settablep.6Value 0 – 9999p.6Text and value display Profilep.6Quick start (to become acquainted)p.6Start of training:p.6End of trainingp.6Snooze modep.6Trainingp.71. Training by power defaultsp.72. Training by pulse defaultsp.7Readiness for trainingp.8Program switchover time / distancep.9orp.10Initial powerp.10Training functionsp.10Change of power profilesp.11Change from speed-independent to speeddependent operationp.11Interruption or end of trainingp.11Resumption of trainingp.11RECOVERY – Functionp.12Recovery pulse measurementp.12*Comment: appears only if the target pulse was achieved once }p.12Individual settingsp.13Or:p.13=>p.14General notesp.14System soundsp.14Speed-dependent operation (running ergometer)p.14Average value calculationp.14Notes on pulse measurementp.14Grade (F) = 6.0 – ( 10 x (P1–P2) )p.14P1p.14Switchover time/distancep.14Profile display during trainingp.14Speed-independent operationp.14Arrows up/down (Speed-independent operation)p.14Training instructionsp.15Warm-upp.15Cool-downp.15Glossaryp.15Scope of loadp.15
Page 2 of the Kettler CTR1 - 07858-600 user manual — Anzeigebereich
Pagina 2 · clicca per ingrandire
Pagina 2

Short description

Pulse measurement with chest strap

The ergometer has a function section with keys and a display section (display) with variable symbols and graphics.

If the chest strap is included in the scope of delivery, the device is already equipped with the receiver. (SD5/7/9/SDC/SDE)

SD4 / SD8 / SD5 / SD9 / SDC

A plug-in receiver is not required.

Ergometer bicycle display SD4B / SD5B /SD8B / SD9B / SDCB / SDEB Cross trainer ergometer display SD4X / SD8X / SDCX / SDEX Running ergometer display SD5S / SD9S / SDCS

Kettler CTR1 - 07858-600 — SD4 / SD8 / SD5 / SD9 / SDC diagram (page 2)
Fig. 1

SD7 / SDE / SDB

Kettler CTR1 - 07858-600 — SD7 / SDE / SDB diagram (page 2)
Fig. 2

Anzeigebereich

Kettler CTR1 - 07858-600 — Anzeigebereich diagram (page 2)
Fig. 3 · Anzeigebereich

(All figures show the electronic unit SD4 – SD9. The functions of the keys are the same as with SD7/SDE/SDB.)

Display

Page 3 of the Kettler CTR1 - 07858-600 user manual — Pulse measurement
Pagina 3 · clicca per ingrandire
Pagina 3
Kettler CTR1 - 07858-600 — Short instruction diagram (page 3)
Fig. 4 · Short instruction

Short instruction

Kettler CTR1 - 07858-600 — Short instruction diagram (page 3)
Fig. 5 · Short instruction

Function section

The six keys are shortly explained in the following.

The more exact application is explained in the individual chapters. In these descriptions the names of the function keys are also used like here.

SET (press shortly)

With this function key, entries are called up.

The set data are accepted.

Ergoracer: During training change from speed-indepen- dent to speed-dependent operating mode.

SET (press longer)

For display of all segmentscall “Individual settings”

Reset

With this function key, the current display is deleted for a restart.

Program

With this function key, the various programs are selected.

Pressing again > next program

Pressing longer > program sequence

Minus – / Plus + keys

With these function keys, values are changed in the various menus before the training and power is changed during the training.

  • To continue “Plus”
  • Or return “Minus”
  • Pressing longer > fast change
  • Pressing “Plus” and “Minus” together:
  • Power jumps to 25 Watt
  • Programs switch to origin
  • Value entry jumps to Off

With this function key, the recovery pulse function is star- ted.

Further functions of the keys are explained in the respec- tive chapters of the operating instructions.

Pulse measurement

Pulse measuring can be carried out in three ways:

1. Ear clip (included in delivery) The plug is put into the female connector.
2a. SD4/SD8/SDBChest strap + plug-in receiver (plug-in)

2b. SD5/SD7/SD9: Chest strap without plug-in. In this electronic unit, the receiver is built in behind the dis- play. A plugged-in ear clip must be removed.

(Chest straps are not always included in delivery)

The Cardio-Pulse-Set with Polar chest strap and plug-in is

available as an accessory (item no. 07937-600). If you already have the Polar chest strap, you will only need the plug-in (item no. 07937-650).

Page 4 of the Kettler CTR1 - 07858-600 user manual — –1 ( RPM )
Pagina 4 · clicca per ingrandire
Pagina 4
Kettler CTR1 - 07858-600 — Display section / display diagram (page 4)
Fig. 6 · Display section / display

3 Hand pulse (for cross trainer ergometers only)

Display section / display

The display section informs about the various functions and respectively selected setting modes.

Kettler CTR1 - 07858-600 — Display section / display diagram (page 4)
Fig. 7 · Display section / display

Programs: Count up / Count down

The programs are distinguished by their counting mode.

Programs

Power via time or distance Default profiles 1–6

Pulse-controlled programs: HRC1/HRC2

Target pulse via time Two programs, which control power by default pulse value.

Interface

The display of this symbol indicates that there is a data connection to a PC.

Display values

The sample displays show operation as ergometer bicycle.

With corresponding speed with the sample displays, the values for speed and distance are lower for cross trainer ergometers and higher for running ergometers.

–1 ( RPM )

Ergometer bicycle = 21.3 km/h

Cross trainer ergometer = 9.5 km/h

Running ergometer = 25.5 km/h

For 60 min

Page 5 of the Kettler CTR1 - 07858-600 user manual — Display section / display
Pagina 5 · clicca per ingrandire
Pagina 5
Kettler CTR1 - 07858-600 — Display section / display diagram (page 5)
Fig. 8 · Display section / display
Page 6 of the Kettler CTR1 - 07858-600 user manual — Snooze mode
Pagina 6 · clicca per ingrandire
Pagina 6

Energy consumption

Dimension settable

Value 0 – 9999

Text and value display Profile

Performance profile 1 point (height) = 25 Watts 1st line = 25 Watts

1 column corresponds 1 minute or 400 m or 0.2 miles Ergoracer: 200 m or 0.1 mile

Running ergometer1 point 35/40 Watts alternating 1st + 2nd line up to 35 Watts

Quick start (to become acquainted)

Kettler CTR1 - 07858-600 — Quick start (to become acquainted) diagram (page 6)
Fig. 9 · Quick start (to become acquainted)
Kettler CTR1 - 07858-600 — Quick start (to become acquainted) diagram (page 6)
Fig. 10 · Quick start (to become acquainted)

Start of training:

  • Greeting display on switching on Display of total kilometers and total training time
  • After 3 seconds: display “Count Up”; all values indicate 0; Power indicates 25 Watts
  • Start of training
  • Display Speed, distance, energy, time, revolutions and power

Alteration of power during the training:

  • “Plus”: display of value in the window “Power” is increased in steps of 5.
  • “Minus” reduces in steps of 5

Continuation of training with these settings. In the meanti- me power alterations are possible any time.

End of training

  • Average values (Ø):

Speed, revolutions, power and pulse (if pulse recording active)

  • Total values Distance, energy and time

Snooze mode

The device switches into the snooze mode with display of the room temperature 4 minutes after the end of training (display of the room temperature only SD4-9). Press any key and the display starts with “Count Up” again.

30 columns · without special settings · display

Page 7 of the Kettler CTR1 - 07858-600 user manual — 2. Training by pulse defaults
Pagina 7 · clicca per ingrandire
Pagina 7

Training

The computer is equipped with 10 training programs. They clearly distinguish in load intensity and duration.

1. Training by power defaults

a)Manual power inputs • (PROGRAM) “Count Up”

Kettler CTR1 - 07858-600 — 1. Training by power defaults diagram (page 7)
Fig. 11 · 1. Training by power defaults
  • (PROGRAM) “Count Down”

b)Power profiles • (PROGRAM) “1” – “6”

2. Training by pulse defaults

Manual pulse defaults • (PROGRAM) “HRC1 Count Up”

Kettler CTR1 - 07858-600 — 2. Training by pulse defaults diagram (page 7)
Fig. 12 · 2. Training by pulse defaults
  • (PROGRAM) “HRC2 Count Down”

Training by power defaults

a)Manual power inputs (PROGRAM) “Count Up”

  • Press “PROGRAM” until: display: “Count Up” Start training, all values count up.
or • Press “SET”default section
  • “Plus” or “Minus”: change power.

Start of training all values count up.

  • Press “PROGRAM” until: display: “Count Down” The program counts from an entered value down > 0. If there is no entry, the training starts in program “Count Up”. For starting the program, at least one entry for time, energy or distance is required.
  • Press “SET”: default section
Default section Displaytime default “Time”

Time default • Enter values with “Plus” or “Minus” (e.g. 45:00) Confirm with “SET”.

Kettler CTR1 - 07858-600 — 2. Training by pulse defaults diagram (page 7)
Fig. 13 · 2. Training by pulse defaults
Displaynext menu energy default “Energy”

Energy default • Enter values with “Plus” or “Minus” (e.g. 1500) Confirm with “SET”.

Displaynext menu distance default “Dist.”

Distance default • Enter values with “Plus” or “Minus” (e.g. 14.00) Confirm with “SET”.

Displaynext menu age input “Age”

Age entry The age entry serves determination and monitoring the maximum pulse (symbol HI, warning sound, if activated

  • Enter values with “Plus” or “Minus” (e.g. 34). From this, a maximum pulse of 186 is calculated according to the relation (220 - age).

Confirm with “SET”.

Displaynext menu maximum pulse input “Max”

(PROGRAM) “Count Down”

Page 8 of the Kettler CTR1 - 07858-600 user manual — Readiness for training
Pagina 8 · clicca per ingrandire
Pagina 8

Maximum pulse entry • Enter values with “Minus” Max Pulse can only be reduced! Confirm with “SET”.

Kettler CTR1 - 07858-600 — Readiness for training diagram (page 8)
Fig. 14 · Readiness for training
Displaynext menu target pulse selection “Fat 65%”

Target pulse selection • Make selection with “Plus” or “Minus”

Kettler CTR1 - 07858-600 — Readiness for training diagram (page 8)
Fig. 15 · Readiness for training
  • Fat burning 65 %, Fitness 75 %, Manual 40 - 90 % Confirm with “SET” (e.g. Manual 40 - 90 %)
  • Enter values with “Plus” or “Minus” (e.g. Manual 83) Confirm with “SET” (end of default mode)
DisplayReadiness for training with all defaults

or Target pulse entry

The entry 40 - 200 serves determination and monitoring of an age-independent training pulse (symbol HI, warning sound, if activated, no maximum pulse monitoring). For that, the maximum pulse entry must be “Off”.

  • Deselect maximum pulse monitoring with “Plus” or “Minus”. Display: “Max Off” Confirm with “SET”.
Displaynext default “Pulse” (target pulse)
  • Enter value with “Plus” or “Minus” (e.g. 130) Confirm with “SET” (end of default mode)
DisplayReadiness for training with all defaults
  • An overview over all setting possibilities in the programs is compiled in the tables (see page 13).
  • The defaults are lost on “Reset”. If for individual settings “Saving of defaults” is activated (page 14), pulse defaults and the set initial power remain stored. With the next selection of Count Up / Count Down, the data is taken over.

Readiness for training

Kettler CTR1 - 07858-600 — Readiness for training diagram (page 8)
Fig. 16 · Readiness for training

Power • Alter power with “Plus” or “Minus”. Start of training by pedaling. The power set before the training is stored.

b) Power profiles (PROGRAM) “1” – ”6” All profiles are selected by pressing “PROGRAM”

e.g. display“1” fitness test according to WHO standard

Automatically controlled increase in power by 25 Watts every 2 minutes, starting with 25 Watts. The recommen- ded pedal revolution is 60 – 80 RPM.

Only persons without any cardiovascular problems are allowed to do this test without medical supervision.

Press “SET”default section,

Default overview, see table on page 13

Page 9 of the Kettler CTR1 - 07858-600 user manual — 2. Training by pulse defaults
Pagina 9 · clicca per ingrandire
Pagina 9
Kettler CTR1 - 07858-600 — Program switchover time / distance diagram (page 9)
Fig. 17 · Program switchover time / distance
  • Press “PROGRAM” until: display: “2” Fitness beginner I; load 25–100 Watt, 27 min Press “SET”: default section, defaults see table p. 13
  • Press “PROGRAM” until: display: “3” Fitness beginner II; load 50–125 Watt, 30 min Press “SET”: default section, defaults see table p. 13
  • Press “PROGRAM” until: display “4” Advanced I; load 50–150 Watt, 36 min Press “SET”: default section, defaults see table p. 13
  • Press “PROGRAM” until: display “5” Advanced II; load 50–200 Watt, 38 min Press “SET”: default section, defaults see table p. 12
  • Press “PROGRAM” until: display “6” Pro I; load 75–300 Watt, 36 min Press “SET”: default section

For times over 30 min, the profile is compressed to 30 columns on the program displays.

Program switchover time / distance

In the programs 1-6, switchover from time to distance mode is possible in the default section.

Kettler CTR1 - 07858-600 — Program switchover time / distance diagram (page 9)
Fig. 18 · Program switchover time / distance
  • Set mode with “Minus” or “Plus” Confirm with “SET”. Display: Readiness for training

The distance per column is 0.4 km (0.2 miles). Cross trai- ner ergometer: 0.2 km (0.1 miles)

2. Training by pulse defaults

Manual pulse defaults (PROGRAM) “HRC1 Count Up”

  • Press “PROGRAM” until: display: HRC1
  • Press “SET”: default section
Page 10 of the Kettler CTR1 - 07858-600 user manual — Training functions
Pagina 10 · clicca per ingrandire
Pagina 10

or

Start training, all values count up. Power is increased automatically until the target pulse is achieved (e.g. 130)

(PROGRAM) “HRC2 Count Down”

  • Press “PROGRAM” until: display : HRC2
  • Press “SET”: default section The entries and setting possibilities are analogue to program point “Count Down”.
  • Start of training Power is automatically increased until the target pulse is achieved (e.g. 130)

Or

Initial power

Kettler CTR1 - 07858-600 — Initial power diagram (page 10)
Fig. 19 · Initial power

In HRC programs determination of the initial power of 25-100 Watts is possible in the default section.

  • Enter values with “Plus” or “Minus” (e.g.. 100) The power is then automatically increased from 100 Watts on, until the target pulse is achieved (e.g. 130)

Pulse • With “Plus” or “Minus” the pulse value can still be changed at this point or during training, e.g. from 130 to 135. Start of training by pedaling.

Default possibilitiessee table page 13
  • For HRC programs, KETTLER recommends pulse measurement with chest strap.
  • Power adjustment in the HCR programs takes place in case of deviations of +/– 6 heartbeats.

Training functions

Display switchover during the training Setting: manual

With “PROGRAM”, the display changes in the points field in the following order: Time / RPM / Speed / Dist. / Power / Energy / Pulse / (Profile) / Time ...

Kettler CTR1 - 07858-600 — Training functions diagram (page 10)
Fig. 20 · Training functions
Settingautomatically ( SCAN )

Press the “PROGRAM” key longer until the “SCAN” sym- bol appears in the display. Change of the displays every 5 seconds. The SCAN function is terminated by renewed pressing of the “PROGRAM” key, the recovery function or interruption of training.

Start training

Page 11 of the Kettler CTR1 - 07858-600 user manual — Resumption of training
Pagina 11 · clicca per ingrandire
Pagina 11
Kettler CTR1 - 07858-600 — Change of power profiles diagram (page 11)
Fig. 21 · Change of power profiles

Change of power profiles

If the power is changed during program run, the change becomes effective to the right of the blinking column. The columns to the left of it show the rendered performance values and remain unchanged.

Change from speed-independent to speeddependent operation

(running ergometer) During training press “SET”. A change from speed-depen- dent to speed-independent operation takes place.

Displayboth arrows under RPM

Pressing “SET” again switches operation back to speed- independent.

The change from speed-dependent to speed-independent operation is only possible in the programs “Count Up” and “Count Down”. The ERGORACER always starts speed-independently. If training is interrupted, operation switches back to speed-independent.

Kettler CTR1 - 07858-600 — Change from speed-independent to speeddependent operation diagram (page 11)
Fig. 22 · Change from speed-independent to speeddependent oper…

Interruption or end of training

For less than 10 pedal revolutions/min or pressing “RECOVERY”, the electronic equipment recognizes an interruption of the training. The training data achieved are displayed. Speed, power, revolutions and pulse are repre- sented as average values with the Ø symbol.

With “Plus” or “Minus” you can change into the current display.

The training data are displayed for 4 minutes. If during this period no key is pressed and no training takes place, the electronic equipment switches into the snooze mode with room temperature display (display of the room tempe- rature only SD4-9).

Resumption of training

When continuing the training within 4 minutes, the last values are further counted or counted down.

Page 12 of the Kettler CTR1 - 07858-600 user manual — *Comment: appears only if the target pulse was achieved once }
Pagina 12 · clicca per ingrandire
Pagina 12

RECOVERY – Function

Kettler CTR1 - 07858-600 — RECOVERY – Function diagram (page 12)
Fig. 23 · RECOVERY – Function

Recovery pulse measurement

At the end of training press “RECOVERY”.

Kettler CTR1 - 07858-600 — Recovery pulse measurement diagram (page 12)
Fig. 24 · Recovery pulse measurement

The electronic equipment measures your pulse reversing for 60 seconds.

If you press “RECOVERY”, the current pulse value is stored under “RPM”; under “SPEED”, the pulse value after 60 seconds is stored. Under “Power”, the difference of both values is displayed. From this, a fitness grade is calcula- ted (for example F 1.1). The display is ended after 20 seconds.

“RECOVERY” or “RESET” interrupts the function. If at the beginning or end of the time rewind no pulse is recorded, an error message is displayed.

Kettler CTR1 - 07858-600 — Recovery pulse measurement diagram (page 12)
Fig. 25 · Recovery pulse measurement

Max. Pulse ✔✔

Kettler CTR1 - 07858-600 — Recovery pulse measurement diagram (page 12)
Fig. 26 · Recovery pulse measurement

For undercutting the entered target pulse (-11 beats), the symbol "LO" is displayed. For exceeding (+11 beats), the sym- bol "HI" is displayed. For exceeding the maximum pulse, the "HI" arrow is blinking and the lette- ring "MAX" is displayed.

*Comment: appears only if the target pulse was achieved once }

Target pulse Fat burning 65% or Fitness 75% ✔ +11 –11* or Manual 40-90%

Page 13 of the Kettler CTR1 - 07858-600 user manual — Or:
Pagina 13 · clicca per ingrandire
Pagina 13
Kettler CTR1 - 07858-600 — Individual settings diagram (page 13)
Fig. 27 · Individual settings

Individual settings

Proceed according to the schemepress “Reset”
Displayall segments
now press “SET” longermenu: Individual Settings
DisplayReset +/–, total kilometers and training time
1. Delete total kilometers and training time Jointly press “Plus” + “Minus”
Kettler CTR1 - 07858-600 — Individual settings diagram (page 13)
Fig. 28 · Individual settings
FunctionDelete display: “Reset O.K.”
Press “Set”switchover to next setting
DisplayStore

Or:

Skip deletion of total values by just pressing “SET”

DisplayStore
2. Storage of defaults Press “Plus” or “Minus” Defaults time, energy, distance, age, target pulse are permanently stored

Function:

ON = Storage also after “Reset”

Off = Storage until next “Reset”

Press “Set”Switchover to next setting
DisplayMetric or English
3. Display of the unit in kilometers / miles Press “Plus” or “Minus”
Functionselection of kilometer or miles display
Press “Set”selected unit is accepted and switchover to the next setting

Display: Temp.

4. Display of temperature in °C / °F (display of the room temperature only SD4-9)

Press “Plus” or “Minus”

FunctionSelect °C or °F
Press “Set”selected unit is accepted and switchover to the next setting

Display: Energy.

5. Display of energy consumption kjoule / kcal Press “Plus” or “Minus”
FunctionSelection of the energy consumption display
Press “Set”selected unit is accepted and switchover to the next setting
DisplayEnergy
6. Display of mechanical / human energy turnover Press “Plus” or “Minus”
Functionselection of the energy turnover display

real.: the energy turnover of the training person with 25 %

efficiency.

phys.: the energy turnover of the device, calculated purely

physically. Press “Set”selected unit is accepted and switchover to the next setting
DisplayAlarm sound ON/OFF
Page 14 of the Kettler CTR1 - 07858-600 user manual — Arrows up/down (Speed-independent operation)
Pagina 14 · clicca per ingrandire
Pagina 14
7. Alarm sound for exceeding maximum Press “Plus” or “Minus”
Kettler CTR1 - 07858-600 — => diagram (page 14)
Fig. 29

=>

Function: switch on or off alarm sound.

Press “Set”selected setting is accepted and “New Start” of display

General notes

System sounds

If a power rate cannot be achieved with speed (e.g. 400 Watts with 50 pedal revolutions), the up or down arrow prompts faster or slower pedaling.

Switching on On switching on, a short sound is emitted during the segment test.

Speed-dependent operation (running ergometer)

End of program An end of program (profile programs, countdown) is signaled by a short sound.

The electromagnetic eddy-current brake sets a constant braking torque.

Average value calculation

Maximum pulse exceeding If the set maximum pulse is exceeded by one pulse beat, 2 short sounds are emitted every 5 seconds.

The average value calculation takes place per training unit.

Notes on pulse measurement

Error output For errors, e.g. recovery not executable without pulse signal, 3 short sounds are emitted.

Pulse calculation starts, when the heart in the display is blinking simultaneously to your pulse beat.

Automatic scan function switching on and off On activation and deactivation of the automatic scan function, a short sound is emitted.

With ear clip The pulse sensor works with infrared light and measures the alterations of the translucency of your skin, which are caused by your pulse beat. Before you clamp the pulse sensor to your ear- lobe, rub it well 10 times to increase circulation.

Avoid disturbing pulses.

  • Attach the ear clip carefully to your earlobe and search for the most suitable point for measuring (heart symbol blinking without interruption).

In the function the centrifugal mass is slowed down automatical- ly. Further training is unsuitable.

Calculation of the fitness grade (F):

  • Do not execute your training directly under strong incidence of light e.g. neon light, halogen light, spot, sun light.

Grade (F) = 6.0 – ( 10 x (P1–P2) )

P1

  • Completely exclude vibrations and wobbling of the ear sensor including the cable. Always fix the cable to your clothing by means of the clip or even better to a headband.

P1 = load pulse, P2 = recovery pulse

F1.0 = very good, F6.0 = insufficient

With chest strap (accessory) Not always included in delivery, available from authorised dealers.

Switchover time/distance

For the programs 1-6, the profile per column can be switched over from the time mode (1 minute) to the distance mode (400 meters or 0.2 miles) in the defaults section. Cross trainer ergo- meter: (200 meters or 0.1 miles)

The Cardio-Pulse-Set with Polar chest strap and plug-in is availa- ble as an accessory (item no. 07937-600). If you already have the Polar chest strap, you will only need the plug-in (item no. 07937-650).

Profile display during training

Interferences at the training computer Press the reset key

At the beginning, the first column is blinking. After completion, it moves on to the right.

With hand pulse An extra-low voltage generated by contraction of the heart is recorded by the hand sensors and analyzed by the electronic equipment

For profiles over 30 minutes up to the middle (column 15), then the profile is shifted from the right to the left. If the profile end appears in the last column (column 30), the blinking column moves further to the right until program end.

  • Always grip the contact surfaces with both hands

Speed-independent operation

  • Avoid jerky gripping
  • Keep your hands still and avoid contractions and rubbing on the contact surfaces.

The electromagnetic eddy-current brake regulates the braking torque for changing pedal speed to the set power.

Arrows up/down (Speed-independent operation)

(constant braking torque) · (constant power)

Page 15 of the Kettler CTR1 - 07858-600 user manual — Scope of load
Pagina 15 · clicca per ingrandire
Pagina 15

Training and Operating Instructions 7926-500, available at your specialist dealer, allows you con- trolling of the KETTLER ergometer with a commercially available PC via this interface.

Empirical rule:

On our homepage www.kettler.de you will find notes on further possibilities with the interface.

Either 10 min / training unit for daily training

or approx. 30 min / training unit for 2–3 times / week

or approx. 60 min / training unit for 1-2 times / week

Training instructions

You should choose the Watts power such that you are able to stand the muscle load over a longer period.

Sports medicine and training science use bicycle ergometry, among others, for examination of the functionality of the cardio- vascular and respiratory system.

Higher powers (Watt) should be yielded in connection with an increased pedaling frequency. A too low pedaling frequency of less than 60 rpm results in a pointedly static load of the muscu- lature and thus to early exhaustion.

Whether your training achieved the desired effects after some weeks you can determine as follows:

1. You achieve a certain stamina with lower cardiovascular performance than before

Warm-up

2. You keep a certain stamina with the same cardiovascular performance over a longer period.

At the beginning of each ergometer training unit, you should for 3-5 minutes pedal with a slowly increasing load to warm and to get your heart/circulation and your musculature moving.

3. After a certain cardiovascular performance you recover faster than before.

Cool-down

Guide values for the stamina training Maximum pulse: maximum load means the achievement of the individual maximum pulse. The maximally achievable heart rate depends on the age.

The same importance has the so-called “cooling down”. After each training unit you should continue pedaling against a slight resistance for approx. 2-3 minutes.

The load for your further stamina training should basically be increased over the scope of load, e.g. instead of 10 minutes your training is 20 minutes or instead of 2 times a week 3 times a week. Beside individual planning of your cardio training you can fall back on the training programs integrated in the training computer (comp. page 9 cont.).

To that applies the empirical formula: the maximum heart rate per minute corresponds 220 pulse beats minus years of age.

Example: age 50 years > 220 – 50 = 170 pulse/min.

Weight: a further criterion for determination of the optimal trai- ning data is the weight. The nominal default for maximum load is 3 Watts/kg body weight for men and 2.5 for women. Furt- hermore, it must be observed, that from age 30 on capability decreases: for men approx. 1 % and for women 0.8 % per year of age.

Glossary

Exampleman; 50 years; weight 75 kg

Age Entry for calculation of the maximum pulse.

> 220 – 50 = 170 pulse/min. maximum pulse

> 3 Watts x 75 kg = 225 Watts

Dimension Units for display of km/h or mph, kjoule or kcal, hours (h) and power (Watt)

> Minus “age discount” (20 % of 225 = 45 Watts)

> 225 – 45 = 180 Watt (nominal default for maximum load)

Speed-independent/speed-dependent operation (running ergometer) Speed-independent operation

Load pulse: the optimal load intensity is achieved at 65–75 % (comp. diagram) of the individual cardiovascular performance. This value changes depending on the age.

Initially, the ERGORACER always works speed-independent. Only during the training the user can select between speed-inde- pendent and speed-dependent operation with the "SET" key. If both direction arrows are displayed, speed-dependent operati- on is selected. Pressing the "SET" key again switches operation back to speed-independent. If the training is interrupted, the dis- play computer automatically switches back to speed-indepen- dent operation.

Pulsediagramm Fitness and Fat Burner 220

Maximalpulse (220 minus Age)

Fitnesspulse (75% of Max.Pulse)

For speed-dependent operation, power has no upper or lower limit. If with a power of over 600 W, operation is switched back to speed-independent, the power display is set to 600 W, and the braking toque is changed respectively. If with a power display of below 25 W, operation is switched back to speed- independent, power is set to 25 W, and the braking torque is changed.

(65% of Max.Pulse)

Age 20 25 30 35 40 45 50 55 60 65 70 75 80

Scope of load

Speed-dependent operation (Count Up, Count Down)

Speed-dependent operation is available during training only. If there is a switchover to speed-dependent operation, the braking torque is kept constant. The displayed power is not changed, until the pedaling speed is changed. With a change in speed, the current power is calculated from the (constant) braking tor- que and the current pedal speed, and displayed respectively. If

Duration of a training unit and its frequency per week: The optimum scope of load is given, when over a longer period 65–75 % of the individual cardiovascular performance is achie- ved.

Load intensity · Pulse · Fat combustion pulse

Page 16 of the Kettler CTR1 - 07858-600 user manual — Training instructions
Pagina 16 · clicca per ingrandire
Pagina 16

the power displayed in speed-independent operation is not sett- able (arrow symbols are shown), the actual power value is dis- played in the moment of switchover. The power can be chan- ged by means of the "+" and "-" keys or by means of speed.

grade is a measure for increase in fitness.

Reset Deletion of display contents and restart of display.

During training, the displayed power is increased or decreased in 5 W (or 25 W, respectively) steps with the "+" or "-" keys, respectively. For that, the current power is taken as standard. The new braking torque is calculated and set. Then the braking torque is kept constant, and the power display is calculated anew for changing pedal speed like described above.

Interface 9-pole SUB-D socket (RS232/serial) for data exchange with a PC.

Control The electronic equipment controls the power or the pulse for manually entered or default values.

A change of the ergometer power by means of the "+" and "-" keys is only possible in the range from 25 W to 600 W. If a key outside this range is pressed, the display jumps to the next possible value within the determined limits and the braking tor- que is changed respectively.

Target pulse Manual or program-determined pulse value, which is to be achieved.

Energy Calculates the energy turnover of the body with an efficiency of 25 % to provide the mechanical power. The remaining 75 % does the body convert to heat.

Fat burning pulse Calculated value of: 65% MaxPuls

Fitness pulse Calculated value of75% MaxPuls

Glossary A collection of attempts for explanation.

HI symbol With “HI” displayed, a target pulse is too high by 11 beats. With HI blinking, the maximum pulse is exceeded.

LO symbol With “LO” displayed, a target pulse is too low by 11 beats.

Manual – Calculated value of40 – 90% MaxPuls

MaxPulse(s) Calculated value of 220 minus years of age

Menu Display in which values are to be entered or selected.

Power Current value of the mechanical (braking) power in Watts, which the ergometer converts into heat.

Profile Change of performance over time or distance represented in the points field.

Programs Training possibilities requiring manual or program-determined performances or target pulses.

Percent scale Comparison display between current power and maximum power (400/600W).

Points field Display area with 30 x 16 points for representing performance profiles as well as text and value displays.

Pulse Recording of the heartbeat per minute

Recovery Recovery pulse measurement at the end of training. From start and end pulse of one minute the deviation and a fitness grade are determined. For the same training, the improvement of this

Fonti

Riferimenti e link

Pagine di riferimento in questo manuale: produttore, supporto e download.

Fai una domanda su Kettler CTR1 - 07858-600

I possessori del prodotto e il nostro team di solito rispondono entro 24 ore, e la tua domanda sarà utile anche ad altri.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Nessuna domanda ancora per il dispositivo Kettler CTR1 - 07858-600

Invia la prima domanda: risponderanno altri possessori o il nostro team.

Documento originale

Kettler CTR1 - 07858-600 manuale in PDF

100 pagine·12.1 MB·Cyclette da casa·PDF
Clicca su qualsiasi pagina in alto per aprirla qui
Pagina 1 / …
100%
Caricamento pagine…