PRINTED IN UNITED ST A TES OF AMERICA WELLS BLOOMFIELD, LLC 2 ERIK CIRCLE, P . O. Box 280 V erdi, NV 89439 www .wellsbloomfield.com telephone: 775-689-5703 fax: 775-689-5976 OPERA TION MANUAL WV G-136.
502 p/n 304986 OpM WVG-136 Ventless Grid dle Unless otherwise specified, all commercial cooking equipment manufactured by WELLS BLOOMFIELD, LLC is warranted against defects in ma terials and workmansh.
WARRANTY ................. .................................... ........... xi SPECIFICATIONS ........... .................................... ........ 1 FEATURES & OPERATING CONTROLS ................... 2 PRECAUTIONS & GENERAL INFO RMATION ..
FEATURES & OPERATING CONTROLS Fig. 1 Ventilator Section Operating Features & Controls 2 28 28 19 16 23 a15 a1 1 53 56 18 9 8 38 VENTIL AT OR CONT ROL P ANEL see pa ges 4 & 5 GRIDDLE CONTRO.
ITEM 1. a6. 8. 9. a10. a11. 12. a15. 16. 18. 19. 22. 23. 28. a31. 38. 40. 41. 42. 43. 44. 53. 56. DESCRIPTION NAMEPLATE FIRE SUPPRESSION AGENT TANK (1.
FEATURES & OPERATING CONTROLS (continued) Fig. 2 Ventilator Section Controls & Indicator Lights Fig. 3 Griddle & Warmer Drawe r Operating Features & Controls 4 502 p/n 304986 OpM WVG-136 Ventless Grid dle GRIDDLE GREASE TROUGH GRIDDLE SURF ACE GREASE DRAWER OPTIONAL ROLL WARMER G.
ITEM V.01 V.02 V.03 V.04* V.05* V.06* G.01 G.02 W.01 W.02 W.03 W.04 W.05 W.06 W.07 W.08 W.09 DESCRIPTION POWER SWITCH POWER ON INDICATOR CHECK FILTERS ALARM INDICATOR REPLACE PREFILTER ALARM INDICATOR.
NOTE: Fire suppression system and all associated comp onents must only be serviced by an authorized Ansu l® Distri butor. All setup, charging, repair and/or adjustment of th e fire sup pression system must be performed by an Authorized Ansul® Distributor ONLY .
AGENCY LISTING INFORMATION OPERATIONAL NOTES: REPLACE PREFILTER and REPLACE FILTER PACK indicator lights provide a timely warning that a system shut-down is i mminent. The actual time between the indicator li ght comin g on and the loss of cooking appliance power will depend upon the cooking conditions.
INSTALLATION NOTE: DO NOT discard the carton or other packing materials until you have inspected the appliance for hidden damage and tested it for proper operation.
SERVICE TECHNICIAN IN STALLATION NOTES An Ansul® technician must charge an d arm the fire suppression system before the ventilator blower will operate.
INSTALLATION (continued) FIRE SUPPRESSION SYSTEM INSTALLATION 1. Any REMOTE MANUAL PULL STATION must b e installed by an authorized ANSUL® distributor in accordan ce with the AUTHORITY HAVING JURISDICTION. NOTE: If a REMOTE MANUAL PULL STAT ION is installed, moving the unit for servic ing will cause the Ansul® system to discharge.
FILTERS INSTALLATION 1. FILTER PACK: Ships installed in the hood. If the FILTER PACK is not in position, the CHECK FILTERS indicator will light. If the FILTER PACK becomes clogged, the REPLACE FILTER PACK indicator will glow. To install the FILTER PACK: Position the filter pack with the charcoal portion UP.
INSTALLATION (continued) WARNING SLIP / FALL HAZARD SPILLED OIL DO NOT OPERATE UNLESS THE GREASE CUP TROUGH AND GREASE DRAWER ARE INSTALLED. Oil and moisture will drip onto the floor and falls may result. Death or serious injury ma y result from slipping and falling GREASE TROUGH AND GREASE CUP INSTALLATION 1.
OPERATION CAUTION: HOT SURFACE Exposed surfaces can be hot to the touch and may cause burns. VENTILATOR OPERATION 1. Press the VENTILATOR POWER switch to ON. The green VENTILATOR POWER light will glow and the blower fan will start. After a short time, if all filters are sensed as being in position and not clogged, the griddle will be energized.
OPERATION (continued) CAUTION: HOT SURFACE Exposed surfaces can be hot to the touch and may cause burns. As manufactured, the steel surface of your Wells griddle has microscopic pores. It is important to fill these pores with oil in order to provide a hard, non-stick cooking surface.
OPERATION (continued) CAUTION: HOT SURFACE Exposed surfaces can be hot to the touch and may cause burns. NOTE: The chart below is intended as a guide ONLY. Your own experience with this appliance, type of foods and method of operation will enable you to determine the temperature control and air vent settings best suited to your operation.
OPERATION (continued) 16 ºF ºC LOAD PROCESS 3 2 5 1 4 RWT- CONTROL MOD ULE SET SETPOINT TEMPERATURE Press an arrow key: UP arrow to increase DO WN arrow to decrease Release key when desire d setpoint temperature is displayed. Reading is locked into memory 3 seco n ds after last key stro k e.
17 CLEANING INSTRUCTIONS CAUTION: ELECTRIC SHOCK HAZARD Disconnect appliance from electric power before cleaning. CAUTION: HOT SURFACE Exposed surfaces can be hot to the touch and may cause burns. Allow appliance to cool before cleaning. IMPORTANT: DO NOT spill or pour water into controls, control panel, wiring or coil-type hotplate elements.
18 502 p/n 304986 OpM WVG-136 Ventless Grid dle CLEANING INSTRUCTIONS (continued) VENTILATOR WEEKLY CLEANING PREPARATION: Disconnect applian ce fro m electric power Allow to cool before cleaning FREQUENCY: Weekly TOOLS: Warm water and a mild detergent Soft clean cloth or sponge Bristle brush Container for disposal of grease 1.
CLEANING INSTRUCTIONS (continued) 19 CAUTION: ELECTRIC SHOCK HAZARD Disconnect appliance from electric power before cleaning. CAUTION: HOT SURFACE Exposed surfaces can be hot to the touch and may cause burns. Allow appliance to cool before cleaning. IMPORTANT: Never allow PRE-FILTER or FILTER PACK to get wet.
DRAWER WARMER DAILY CLEANING PRECAUTIONS: Turn control knob to OFF. Allow drawers to cool before proceeding. R e m o v e d r a w e r pans and Humitrol racks. FREQUENCY: Minimum -Daily TOOLS: Warm water and mild detergent Clean cloth or sponge 1. R emove drawe rs from warmer : a.
MAINTENANCE SCHEDULES USE AND MAINTENANCE SHALL BE IN ACCORDANCE WITH THE STANDARD FOR VENTILATION CONTROL AND FIRE PROTECTION OF COMMERCIAL COOKING OPERATIONS , N.F.P.A 17A & N.F.P.A. 96 (current editions). DANGER FIRE HAZARD FAILURE TO PROPERLY CLEAN AND MAINTAIN THIS EQUIPMENT CAN CAUSE A FIRE.
22 WELLS BLOOMFIELD, LLC 502 p/n 304986 OpM WVG-136 Ventless Grid dle.
23 WELLS BLOOMFIELD, LLC Replace two (2) fire suppression links at cooking appliance: each link is rated @ 212ºF Replace fire damper fusible link: rated @ 280ºF Max interval: 12 months 502 p/n 30498.
24 ANSU L ® ANSUL INCORPORA TED MAR I N ET T E, WI 541 43 - 25 42 MA TERIAL SAFETY D A T A SHEET ANSULEX L ow pH QUICK IDENT IFIER (In Plant C ommon Name) Manufa c turer’s Name: Eme rgenc y T elephone No.
25 SECTION 5 - HEAL T H HAZ ARDS SECTION 6 - EMERGENCY AND FIRST AID PROC EDURES SECTIO N 7 - SPECIAL PROTECTIO N INFOR M A TION SECTIO N 8 - SPECIAL PRECAUT I ONS AND SPI LL/LEAK PR OCEDURES HAZARDOU.
TROUBLESHOOTING SUGGESTIONS SYMPTOM Ventilator blower won’t run Ventilator blower won’t run - buzzer sounding Ventilator blower runs momentarily, shuts down.
D E S C R I P T I O N S E R V I C E P A R T N O . PRE-FILTER 22618 PRE-FILTER CAGE 22683 FILTER PACK (HEPA + CHARCOAL) 22619 GREASE BAFFLE 22684 LEG KIT 22649 CASTER KIT 22650 GREASE CUP 22626 SCRAPER.
Genuine Parts Protect - YOU - All - W ays SER VICE TRAINING - QUALITY SER VICE SER VICE TRAINING - QUALITY SER VICE CUSTOMER SA TISF ACTION CUSTOMER SA TISF ACTION Commercial Food Equipment Service As.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Bloomfield WVG-136RWT è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Bloomfield WVG-136RWT - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Bloomfield WVG-136RWT imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Bloomfield WVG-136RWT ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Bloomfield WVG-136RWT, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Bloomfield WVG-136RWT.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Bloomfield WVG-136RWT. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Bloomfield WVG-136RWT insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.