The design of the operator is not suitable nor intended for the opening and closing of heavy doors, i.e. doors that can no longer be opened or closed manually or where this is only possible with great difficulty. For this rea- son, before installing the operator it is neces- sary to check the door and make sure that it can still be easily moved by hand.
Thank you for placing your confidence in us by purchasing a Hörmann product. Please keep these instructions safe for later refe- rence. Please observe the following instructions. They provide you with important information on the safe installation and operation of your garage door operator to ensure that this pro- duct will give you pleasure for many years to come.
This garage door operator is designed for the automatic operation of domestic spring- balanced up-and-over doors and sectional doors. Use in the commercial sector is not permitted. In the event that the customer carries out his own structural changes or undertakes improper installation work or arranges for same to be carried out/under- taken, without Hörmann’s prior approval and contrary to the manufacturer’s given guideli- nes, then Hörmann KG shall be exempt from its guarantee obligations and product liability.
To carry out this check, raise the door approx. 1 metre and then let it go. The door should stay in this position, neither moving up nor down. However, if the door should move in any of the two directions, there is a risk that the compensating springs are incor- rectly adjusted or defective. In this case increased wear and malfunctioning of the door system can be expected. Do not attempt to change, re-adjust, repair or move the compensating springs for the door’s counterbalance nor their holders. The springs are under great tension and can cause serious injury. For your own safety, only allow work on the door’s compensating springs to be carried out by your garage door’s service engineers.
In the interests of human safety it is vital that the instructions contained in this instruction manual be followed in full.
Any further processing must ensure that the national regulations governing the operation of electrical equipment are complied with. Moreover, we shall accept no responsibility for the inadvertent or negligent operation or improper maintenance/servicing of the door, the accessories and the weight counterba- lance of the door. Batteries and light bulbs are not covered by the guarantee.
Dear Customer,

In addition, check the entire door system – joints/hinge points, door bearings, cables, springs and fastenings – for wear, possible damage and faulty counterbalance mecha- nism. Check for signs of rust, corrosion or fractures. The door system may not be used if repair or adjustment work needs to be car- ried out. Always remember that a fault in the door system or a wrongly aligned door can cause injury.
Caution notices warning about the trap risk must be permanently fixed in a conspicuous place in the proximity of the permanently installed buttons used to actuate the opera- tor. The garage ceiling must be constructed in such a way so as to guarantee safe, secure anchoring of the operator. In the case of ceilings which are too high or too light- weight, the operator must be attached to additional braces. The operator is designed for use in dry buil- dings and therefore may not be installed out- doors. The door height must not exceed a maxi- mum of 3 metres. The clearance between the highest point of the door and the ceiling (also during the up-and-over action of the door) must be at least 30 mm. Please check the dimensions. If there is inadequate clea- rance, the operator may also be installed behind the opened door, provided sufficient space is available. In such instances, an extended door link must be used. The door operator can be positioned off- centre by a maximum of 500 mm, the exception being sectional doors with high-lift tracks (track application ”H”) where a special
Before the operator is installed, any of the door’s mechanical locks and latches not needed for power operation of the garage door, should be immobilised. This includes in particular any locking mechanisms connec- ted with the door lock.
Before installing the operator, have any necessary maintenance and repair work car- ried out by your garage door’s service engineers. The function of the mechanical release must be checked once a month on an opened door. This calls for caution since a door with weak, broken or defective springs or a faulty counterbalance mechanism can quickly slam to of its own accord.
Before installing the garage door operator, check that the door is in a good mechanical condition, is correctly balanced and opens and closes in the proper manner. Perma- nently installed controls (such as buttons or similar devices) should be installed within sight of the door but well away from any moving parts and at a height of at least 1.5 metres. It is imperative that they be installed well out of the reach of children!

track fitting is required. The required shockproof electric socket should be installed next to the operator head at a distance of approx. 50 cm.
Make sure that neither persons nor objects are located within the door’s range of travel.
Instructions for Using the Operator
Before carrying out any work on the opera- tor, disconnect the mains plug. Instruct all persons using the door system how to ope- rate it properly and safely. Demonstrate and test the safety return and the mechanical release. Only ever operate the door provided the door’s range of travel is located within your field of vision.
Initial function checks as well as program- ming or extending the remote control should always be carried out from inside the garage.
In carrying out the installation work, the applicable regulations regarding working safety must be complied with. Make sure that the cable of the operator’s mechanical release cannot get caught up in the ceiling’s support system or in any other protruding parts of vehicles or the door.
Wait until the door has come to a complete halt before entering the door’s range of tra- vel. Before driving in or out of the garage, make sure that the door has opened fully.

Tensioning the Drive Belt
Figures 5.1 and 5.2 For other makes the clearance between the door at its highest point of travel and the ceiling must be at least 30 mm.
The operator’s toothed belt has been opti- mally pretensioned at the factory. During the starting and braking phases of large doors it can happen that the drive belt hangs out of the profiled boom briefly. This, however, is of no technical disadvantage nor does it have a negative effect on the operator’s function and service life. If the pretension of the belt is increased, this can cause unnecessary wear on the bearings as well as have a detri- mental effect on the overload recognition system.
= See text part
The ilustrated part presents the fitting of the operator to an up-and-over door. Where installation differs, a sectional door may also be shown. In this instance, the letter O a is assigned to the up-and-over door and the letter O b to the sectional door.
Figure 13 Engage the carriage.
Figure 2a For door models not listed here, immobilise the catches/snap lock on site.
Figure 16 Connecting the remote control The wiring of the radio receiver is to be connected as follows: - green wire to terminal 20 (0V) - white wire to terminal 21 (signal) - brown wire to terminal 5 (+24V)
Maintenance Instructions The garage door operator is maintenance- free. For your own safety, however, we recommend that you have the door system checked once a year by a specialist.
Figure 4a.2 For doors with a wrought iron handle, fit the boom off-centre.
Figure 4a.3 For doors with timber infill, increase the given dimensions by 10 mm.
Figure 18 Connecting an external ”IMPULSE” button (sequential controls: OPEN- STOP-CLOSE) One or more buttons can be connected parallel to the remote control at terminals 20 and 21.
Airborne noise emission of the garage door operator: at a distance of 3 m the equivalent continuous sound pressure level of 70 dB(A-weighted) is not exceeded.
Figure 3b For doors with a centrally positioned lock, fit the boom off-centre.
Description for operating

Figure 20 Connecting an external ”OPEN” button An external ”OPEN” button can be connec- ted to terminals 15 and 14.
Figure 24 Connecting a photocell Photocells switching to ground (0V) must be connected as follows:
With closing edge safety devices without test input, do not connect terminal 18.
Figure 26 Connecting terminals for external lighting, flashing light or revolving beacon
Connection Terminal Earth (0V) 20 Switching output signal 71 Test input (optional) 18 Supply (+24V) 5
Figure 21 Connecting an external ”CLOSE” button An external ”CLOSE” button can be connec- ted to terminals 17 and 14.
Terminal 5 – 6 openers contact load 2.5A/30V DC 500W/250V AC Terminal 5 – 8 closers contact load 2.5A/30V DC 500W/250V AC
Figure 22 Connecting a light switch An external switch allowing the operator lighting to be switched on/off can be connected to terminals 10 and 20.
With an uninterrupted light path the swit- ching output (signal) = 0 volts. With a photo- cell without test input, do not connect terminal 18.
For setting/adjusting see figure 34 (function of the option relay)
Figure 25 Connecting a closing edge safety device Closing edge safety devices switching to ground (0V) must be connected as follows:
Figure 23 Connecting an OFF switch In the ex-factory state, terminals 12 and 13 are bridged. Here an OFF switch with opener contact can be connected. For connection, remove the wire bridge.
Figure 28 Installation layout
Figure 29 SupraMatic E/P wiring diagram
Connection Terminal Earth (0V) 20 Switching output signal 19 Test input (optional) 18 Supply (+24V) 5
General Information The operator contains seven menus, from which the user can select numerous func- tions. All this requires is allowing the operator to learn and memorise the door’s travel path.
With an uninterrupted light path the swit- ching output (signal) = 0 volts.

On initial operation, the control unit automati- cally changes to the learn menu. After com- pleting its learn travel cycle or after 60 secs., there is always an automatic change to menu O (normal operation).
button (). After closing, the operator will reverse direction. The door system is then ready for operation.
Figure 31 Setting the operator lighting Select menu 2 by pressing the PRG button. The flashing figure displayed indicates the setting of the operator lighting.
Operation after a power failure
Display Operator lighting 0 Lighting OFF 1 60 secs. 2 90 secs. 3 120 secs 4 150 secs. 5 180 secs. (factory setting) 6 210 secs. 7 240 secs. 8 270 secs. 9 300 secs.
Tuning the operator In order to tune the operator to the door, a so called learn travel cycle must first be completed. During this learn travel cycle, the length of the travel path as well as the required force for opening and closing the door are learned and auto- matically stored.
In the event of a power failure, the stored door data is retained. However, the door must then be allowed to complete one full opening cycle (reference travel cycle) so that the correct function can be guaranteed. During this reference travel cycle it is impor- tant that the belt carrier is engaged in the carriage. If this is not the case, the belt carrier will travel into the drive wheel, and the operator will then register this as its reference point. If this should happen, allow the operator to travel in the CLOSE direction until you can engage the belt carrier in the carriage. After isolating the operator from
Figure 30 Tuning the travel limits (attention: the carriage must be engaged! See figure 13)
Afterwards, change to menu 0 by pressing the PRG button.
Switch the control unit, if necessary, to the learn mode by pressing the PRG button to change to menu 1. A flashing ”L” now shows up in the display. Press the OPEN button () to allow the door to open right up to its mechanical limit stop. Proceed in the same way for the CLOSE
the mains, repeat the reference travel cycle.
For safety reasons it is only possible to close the door following a power failure in the press-and-hold mode.

Figure 32 Setting the automatic timer (for safety reasons we recommend fitting a photo- cell and/or closing edge safety device) Select menu 3 by pressing the PRG button. The flashing figure displayed indicates the set waiting time of the door in the OPEN position, which can be altered using the OPEN or CLOSE buttons.
Figure 33 Setting the photocell/closing edge safety device Select menu 4 by pressing the PRG button. The flashing figure displayed indicates the following settings which can be altered using the OPEN or CLOSE buttons: LS = photocell SKS = closing edge safety device
Display Waiting time 0 No automatic timer
(factory setting) 1 10s 2 20s 3 30s 4 40s 5 50s 6 60s
0 no (factory setting)
1 yes no no no 2 yes yes no no 3 no no yes no 4 yes no yes no 5 yes yes yes no 6 no no yes yes 7 yes no yes yes 8 yes
When the automatic timer is active, the ope- rator lighting flashes two seconds before the start of travel. If during this time the remote control is operated, the set waiting time starts afresh. Change to menu 0 by pressing the PRG button.
Change to menu 0 by pressing the PRG button.

Figure 34 Setting the function of the option relay Select menu 5 by pressing the PRG button. The flashing figure displayed indicates the set function of the option relay, which can be altered using the OPEN or CLOSE buttons:
sarily high setting should not be selected. If the closing force is set too high, this can result in damage to property or injury to per- sons.
Change to menu 0 by pressing the PRG button.
Display Function 0 Relay OFF (factory setting) 1 2s warning phase before every door movement: flashing 2 2s warning phase before every door movement: permanent light (e.g. revolving beacon) 3 Relay picks up with the opera tor. Lighting (external light)
Figure 36 Correcting the belt relief In menu 7 the automatic belt relief at the CLOSE travel limit can be influenced:
Display Function 0 Automatic relief (faxtory setting) 1 No relief (observe belt tension!) 2 Always short relief 3 Always medium relief 4 Always long relief
Change to menu 0 by pressing the PRG button.
Figure 35 Correcting the closing force In menu 6 (factory setting = 0) the automatic power limit for closing the door can be altered to a less sensitive setting. This is only necessary for doors which run extremely unevenly. An unneces
Change to menu 0 by pressing the PRG button.

Trouble-Shooting and Test Instructions
Belt torn Operator defective
Replace belt Replace operator
Reprogramme the operator, if necessary replace
Door too sluggish Obstruction in the door area
Assure smooth running of the door, re-programme operator if necessary
Clamp 12 and 13 empty, ”Off button” activated
Bridge 12, 13, switch off button to on
Spring tension not okay Springs broken
Correct the spring tension (caution!) Replace the springs
Light beam interrupted Photocell defective
Adjust photocell Exchange photocell
Closing edge safety device
Check transmitter and receiver, if necessary replace Replace closing edge safety device
Open door up to "OPEN" travel limit
Operator has not memorized the code
Operator has not yet been "taught" the codet
Programme the operator with the code