IT
Flex logo
Manuale d'uso ufficiale

Flex S47

141 pagine·14.5 MB·Varie·PDF·ENJA
Flex S47
Indice dei contenuti 29 sezioni Proper use · Start up · Anti-static system · Contents · … MostraNascondi
Page 2 of the Flex S47 user manual — Wet vacuum cleaning
Pagina 2 · clicca per ingrandire
Pagina 2
Flex S47 — Wet vacuum cleaning diagram (page 2)
Fig. 1 · Wet vacuum cleaning

Removing disposal bag, closeable (op- tional)

Flex S47 — Wet vacuum cleaning diagram (page 2)
Fig. 2 · Wet vacuum cleaning

Î Release and remove the suction head. Î Attach disposal bag. Î Pull disposal bag over the container. Î Insert and lock the suction head.

Î Close and remove disposal bag. – To suck wet dirt, always remove the closeable disposal bag (optional). Warning The flat pleated filter must must always be in place while vacuuming. – If wet dirt is vacuumed with the uphol- stery or crevice nozzle, or if water is sucked up from a container, it is recom- mended to deactivate the "automatic fil- ter cleaning" function. – If the maximum liquid level is reached the appliance will turn off automatically. – In case of non-conductive liquids (such as emulsion drilling fluids, oils, and greases) the appliance is not turned off when the container is full. The filling level must be continu- ously monitored and the container must be emptied in time. – After having completed the wet vacuum operation clean the flat pleated filter, the electrodes and the container and let dry.

Wet vacuum cleaning

Inserting the rubber lips

Flex S47 — Wet vacuum cleaning diagram (page 2)
Fig. 3 · Wet vacuum cleaning

Î Remove the brush strips (4). Î Insert the rubber lips (5). Note The structured side of the rubber lips must point outwards.

Page 3 of the Flex S47 user manual — Adjust the suction output
Pagina 3 · clicca per ingrandire
Pagina 3

Clip connection

Working with electrical power tools

The suction hose is equipped with a clip system. All C-35/C-DN-35 accessories can be connected.

Î Connect the mains plug of the electric

power tool to the vacuum cleaner (3). Î Turn on the appliance (1). Lamp is on - vacuum cleaner is in the standby mode (2). Note – The vacuum cleaner is turned on and off automatically with the electric power tool. – The vacuum cleaner starts automatical- ly within 0.5 seconds and continues to run for 15 seconds after the power tool has been switched off. – Please refer to "Technical specifica- tions" for the power connection specifi- cations of the power tools.

Operation

Turning on the Appliance

Î Plug in the main plug. Î Turn on the appliance.

Adjust the suction output

Î Adjust the stepped power tool adaptor

to fit the connection of the electric pow- er tool.

Î Set the suction output (mix - max) at the

rotary switch.

Page 4 of the Flex S47 user manual — Automatic filter cleaning
Pagina 4 · clicca per ingrandire
Pagina 4
Flex S47 — Automatic filter cleaning diagram (page 4)
Fig. 4 · Automatic filter cleaning

the switch goes off. – To switch on automatic filter cleaning: Î Press the switch again. Indicator lamp

hose. Î Attach the stepped power tool adaptor

Î Turn off the appliance. Î Pull out the mains plug. Î Empty the container. Î Vacuum and wipe the appliance inside

to the suction hose.

Flex S47 — Automatic filter cleaning diagram (page 4)
Fig. 5 · Automatic filter cleaning

and outside.

Flex S47 — Automatic filter cleaning diagram (page 4)
Fig. 6 · Automatic filter cleaning

Î Connect the adaptor to the electric pow-

er tool.

Automatic filter cleaning

The appliance has an innovative filter cleaning system that is particularly effective with fine dust. The flat pleated filter is auto- matically cleaned every 15 seconds through an air jet (pulsating sound). Note Automatic filter cleaning is switched on at the factory.

cable as shown in the illustration. Î Place the appliance in a dry room and

Warning First remove the mains plug before doing any job on the vacuum cleaner.

Flex S47 — Automatic filter cleaning diagram (page 4)
Fig. 7 · Automatic filter cleaning
Page 5 of the Flex S47 user manual — Suction turbine turns off
Pagina 5 · clicca per ingrandire
Pagina 5
Flex S47 — Suction turbine does not start again diagram (page 5)
Fig. 8 · Suction turbine does not start again

Suction turbine does not start again

after the container has been emp-

tied

Î Turn off the appliance and wait for 5

seconds, turn it on again after 5 sec- onds. Î Clean the electrodes as well as the

space between the electrodes.

Suction capacity decreases

Î Remove blockages in the suction noz-

Î Open filter door. Î Replace the flat pleated filter. Î Close the filter door, it must lock into

zle, suction tube, suction hose, or flat pleated filter. Î Close and replace full disposal bag (op-

tional). Î Ensure the filter cover properly locks

into place. Î Replace the flat pleated filter.

Dust comes out while vacuuming

Î Check for proper installation of the flat

pleated filter. Î Replace the flat pleated filter.

Automatic shut-off (wet vacuum

cleaning) does not react

Î Clean the electrodes as well as the

space between the electrodes. Î Continuously check the filling level in

Î Release and remove the suction head. Î Clean the electrodes. Î Insert and lock the suction head.

case of non-conductive liquid.

Automatic filter cleaning is not

Troubleshooting

working

Suction turbine does not run

Î Suction hose is not connected.

Î Check cables, plugs, fuse, socket and

Automatic filter cleaning cannot be

electrodes. Î Turn on the appliance.

switched off

Î Inform Customer Service

Suction turbine turns off

Automatic filter cleaning cannot be

switched on

Î Empty the container.

Î Inform Customer Service

Page 6 of the Flex S47 user manual — Accessories and Spare Parts
Pagina 6 · clicca per ingrandire
Pagina 6

Warranty

CE declaration

The warranty terms published by our com- petent sales company are applicable in each country. We will repair potential fail- ures of your appliance within the warranty period free of charge, provided that such failure is caused by faulty material or de- fects in fabrication. In the event of a warran- ty claim please contact your dealer or the nearest authorized Customer Service cent- er. Please submit the proof of purchase.

We hereby declare that the machine de- scribed below complies with the relevant basic safety and health requirements of the EU Directives, both in its basic design and construction as well as in the version put into circulation by us. This declaration shall cease to be valid if the machine is modified without our prior approval.

ProductWet and dry vacuum cleaner

Accessories and Spare Parts

TypeFLEX S 47

– Only use accessories and spare parts which have been approved by the man- ufacturer. The exclusive use of original accessories and original spare parts ensures that the appliance can be oper- ated safely and troublefree. – At the end of the operating instructions you will find a selected list of spare parts that are often required.

Relevant EU Directives 2006/95/EC 89/336/EEC (+91/263/EEC, 92/31/EEC, 93/68/EEC) Applied harmonized standards EN 55014–1: 2000 + A1: 2001 + A2: 2002 EN 55014–2: 1997 + A1: 2001 EN 60335–1 EN 60335–2–69 EN 61000–3–2: 2000 + A2: 2005 EN 61000–3–3: 1995 + A1: 2001 Applied national standards --

5.957-687

The undersigned act on behalf and under the power of attorney of the company man- agement.

FLEX Elektrowerkzeuge GmbH Bahnhofstr. 15 71711 Steinheim/Murr

Fai una domanda su Flex S47

I possessori del prodotto e il nostro team di solito rispondono entro 24 ore, e la tua domanda sarà utile anche ad altri.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Nessuna domanda ancora per il dispositivo Flex S47

Invia la prima domanda: risponderanno altri possessori o il nostro team.

Documento originale

Flex S47 manuale in PDF

141 pagine·14.5 MB·Varie·PDF
Clicca su qualsiasi pagina in alto per aprirla qui
Pagina 1 / …
100%
Caricamento pagine…