Technical data Power consumption 350 - 1200 W Connected load to appliance plug socket max.: EC 2400 W CH, DK 1100 W GB 240 V/110 V 1800 W/500 W AUS 1200 W Volume fl ow (air) max., turbine 228 m³/h Vacuum max., turbine 23000 Pa Filter surface 14000 cm2 Suction hose Ø 27 mm x 3.5 m Sound pressure level in compliance with DIN 60704-1 72 dB(A) Power cable length 7.5 m Protection type IP X4 Container capacity CTM 22 E SG 22 l CTM 33 E SG/CTM 33 LE SG 33 l CTM 44 E/CTM 44 LE 44 l CTM 55 E 55 l Dimensions L x W x H CTM 22 E SG 625 x 380 x 550 mm CTM 33 E SG/CTM 33 LE SG 625 x 380 x 660 mm CTM 44 E/CTM 44 LE 710 x 380 x 935 mm CTM 55 E 710 x 380 x 935 mm Weight CTM 22 E SG 13.1 kg CTM 33 E SG/CTM 33 LE SG 15.6 kg CTM 44 E/CTM 44 LE 20 kg CTM 55 E 22 kg
The specifi ed illustrations can be found at the beginning of the operating instructions.
ance with EN 60335-1 and EN 60335-2-69 for a higher loading in industrial use.
2 Safety instructions - Only use original Festool accessories.
Manual, read the instructions

dust hazardous to health.
hazardous to health. Emptying and main- tenance operations, including removal of the dust collection means, must only be carried out by authorised personnel wear- ing suitable personal protection. Do not operate without the full fi ltration system fi tted. - The machine is not intended for use by
1 Intended use The vacuum cleaners are designed as specifi ed for the aspiration and evacuation of noxious dusts industrial threshold limit values (LTL-values) up to 0.1 mg/m³ and of wood dusts corresponding to dust class ‘M’ in accordance with IEC 60335-2-69. The vacuum cleaner is designed as specifi ed for extracting water. The vacuum cleaner is designed in accord-
persons (including children) with limi- ted physical, sensory or mental ability or without suffi cient experience and/or
Pictograms

knowledge, unless they are supervised by a person responsible for their safety or have been instructed on how to use the machine. Children should always be supervised to ensure that they do not play with the machine. - If used to extract dusts with LTL values or
3 Appliance preparation and initial operation The accessories are delivered horizontal in the container (2.10), and must be removed prior to initial operation.
3.1 Power supply
large quantities of beech or oak sawdust, only one dust source (electric or air tool) may be connected. - The appliance may be operated only in an
The line voltage and frequency must correspond with the data on the rat- ings plate! Make sure that the vacuum cleaner is switched off when you plug the power cable in. The antistatic system (AS) Friction in the suction hose causes electro- static charges which can result in unpleas- ant electric shocks for the operator. In order to conduct these static charges to earth, the extraction units are provided with an antistatic system as a standard feature. However, antistatic hoses and accessories have to be used in this case. The antistatic function will only work if the plug is plugged into a totally earthed socket.
adequately ventilated space (in compliance with national industrial safety provisions). - Do not suck in any sparks or hot chip-
pings. - With the exception of wood dust, do not
suck in any fl ammable or explosive dusts such as magnesium, aluminium etc. - Risk of explosion! - Do not use to extract fl ammable or explo-
sive liquids (e.g. petrol, thinners) - Risk of explosion! - Do not use to extract aggressive liquids/
dry materials (e.g. acids, alkalis, sol- vents). - Remove plug from mains socket when not
3.2 On/off switch (1.3) In position 0 the vacuum cleaner is switched off and the appliance plug socket (1.7) is dead. Before switching on, the rotary knob (1.2) must be adjusted to the diameter of the connected suction hose.
in use and before maintenance work. - Do not pull plug out of mains socket by
its cable. - Protect the cable against heat, oil and
sharp edges. - Check the plugs and cables regularly and
Two modes of operation are possible: a) Switch position „MAN“ The appliance plug socket is dead. The cleaner motor starts immediately.
have them replaced by an expert if dam- aged. - Do not leave devices out in the rain. - Do not lift or carry the devices by their
handles using a crane hook or lifting gear. - The device may only be used by persons
b) Switch position „Auto“ The appliance plug socket is live.
who have been trained in its use and who are authorised to do so. - If noxious dusts have been extracted,
Before turning the switch to the „Auto“ position, ensure that the tool connected to the appliance plug socket is switched off. The cleaner motor starts only when the tool connected to the appliance plug socket is switched on.
the vacuum cleaner and all accessories must be completely cleaned (inside and outside) by suction and wiping, before re- moval from the contaminated area. Parts that cannot be completely cleaned are to be packed for transport in a plastic bag with an airtight seal. The suction opening (1.14) must be sealed with the blanking plug (1.13) for transport purposes. - For safety reasons, only operate the ma-
3.3 Suction force regulator (1.4) The suction force regulator can be used to vary the suction capacity. This permits a precise adaptation to different substances to be picked up.
chine using a totally earthed socket.

3.4 Temperature control A temperature fuse switches the dust ex- tractor off before this reaches a critical temperature to protect against overheat- ing - switch dust extractor off and leave for around 5 minutes to cool down. If the dust extractor still cannot be switched back on, please consult a Festool-service centre.
4.2 Changing the fi lter
During the following procedure, take care not to raise dust more than is unavoidable.
Wear a P2 breathing protection mask
a) Changing the fi lter bag (3.4) Order no.: CTM 22 E SG 452970 CTM 33 E SG/CTM 33 LE SG 452971 CTM 44 E/CTM 44 LE 452972 CTM 55 E 452973 - Open the vacuum cleaner, - Remove the used fi lter bag (see printed
3.5 Connecting an electric tool
Observe the maximum connected load on the appliance plug socket (see “Technical Data“)!
Make sure that the electric tool is switched off when plugging it in and unplugging it. Connect the electric tool to the appliance plug socket (1.7).
text on fi lter bag), - Dispose of the used fi lter bag in accord-
ance with statutory requirements, - Thoroughly clean the dirt container (2.10)
and the space (3.1) for suction turbine (wipe down with a damp cloth), - Insert new fi lter bag (see printed text on
3.6 Connecting pneumatic tools
Make sure that the pneumatic tool is switched off when plugging it in and unplugging it. When the compressed-air module (1.8) (452829; supplied ready with CTM 33 LE SG and CTM 44 LE) is fi tted, the automatic cut-in of the appliance also operates in conjunction with compressed-air tools. We also recommend fi tting of the VE supply unit (452797). The supply unit fi lters and oils the compressed air and allows the air pressure to be regulated. An IAS connecting piece (454757) is available for connecting Festool compressed-air tools with the IAS system. To ensure trouble-free functioning of the automatic cut-in, the operating pres- sure of the tool must be 6 bar.
fi lter bag). Important: Press the fi lter bag sleeve (3.3) fi rmly onto the dust ex- traction fi tting (3.2)! - Close the vacuum cleaner.
b) Changing the filter element (2.3) Order no.: 452923
Do not operate machine without a fi lter element. This may damage the motor. - Open the vacuum cleaner, - Remove the used fi lter element (see print-
ed text on the fi lter element packaging), - Dispose of the used fi lter element in a
sealed, dust-tight bag in accordance with statutory requirements, - Thoroughly clean dirt container (2.10) and
4 Operation 4.1 Opening/closing the vacuum cleaner - Open retaining clamps (2.2), - Raise upper part (2.4) until support catch
space (3.1) for the suction turbine (wipe down with a damp cloth), - Fit a new fi lter element (see printed text
on the fi lter element packaging), - Close vacuum cleaner.
(2.5) engages. Follow the reverse order to close the appli- ance. You must raise the upper part slightly before depressing or disengaging the support.
4.3 Cleaning the fi lter element To clean, move the handle (2.1) to and fro about 10 times. N.B.: You need to clean the fi lter element only if you use the vacuum cleaner without a fi lter bag.
with health-hazardous dusts!

4.4 Emptying the dirt trap (2.10) Always remove the upper part of the vacuum cleaner before emptying the dirt container! - Open the vacuum cleaner, - Raise the upper part slightly, depress the
5.1 Vacuuming dry materials
A fi lter bag must be used without exception when evacuating noxious substances! Before using the vacuum cleaner to evacu- ate dry substances, a fi lter bag must always be inserted in the container. Then the evacuated material can be dis- posed of easily. The fi lter element becomes damp after evacuating liquids. A damp fi lter element suffers more wear and tear if it is used for dry materials. Accordingly, the fi lter element should be dried or replaced with a dry one before dry operation.
support (2.5), - Raise the upper part to the stop (vertical
position), - Remove the upper part by moving it for-
wards horizontally, - Empty the dirt container, - Replace the upper part. Warning: Make
sure that both upper-part pins are fully inserted in the recesses (1.5)! - Close the vacuum cleaner.
5.2 Vacuuming liquids
Do not evacuate combustible liquids!
4.5 Stand/Brake The wheels can be blocked by the brakes (2.8), thus preventing the vacuum cleaner from rolling away unexpectedly.
If foam or liquid escapes, stop work immediately and empty the dirt con- tainer. The fi lter bag has to be removed before evacuating liquids. We recommend use of a special wet fi lter. When the maximum fi lling level is reached, a bag-full indicator (2.12) automatically interrupts extraction.
4.6 Hose depot (partly in scope of delivery) Securing the hose depot on the dust extrac- tor: see Fig. 4. When work is complete, you can guide the extractor hose through the opening (4.1) and deposit the hose in the depot. Similarly, the mains cable can also be guided through the opening (4.2) and deposited in the hose depot.
5.3 Volume fl ow monitoring If the air speed in the suction hose drops below 20 m/s, an acoustic warning signal sounds for safety reasons.
Possible causes and adjustments Cause - Adjustment Suction force regulator (1.4) set to a too low value - Adjust suction force regulator to a higher
5 Application - A systainer can be fi xed to the storage
area (1.12) with the two clamps (1.10). Tools or accessories can also be stowed on the storage area and in the storage compartments (1.6, not with CTM 22). - A hose coupling (1.11) (487072) can be
value Rotary knob (1.2) not adjusted to the connected hose diameter - Adjust to correct hose diameter Suction hose blocked or twisted - Remove blockage or twist Filter bag full - Change fi lter bag Filter element dirty - Change fi lter element - Only when operating without a fi lter bag:
plugged into the opening (1.8). The suc- tion hose is connected to the tool from above with the hose coupling. Alterna- tively, a hose clip (452998) can be fi tted for coiling the suction hose. - The push handle (2.11) (452921; supplied
ready with CTM 44 and CTM 55) makes the vacuum cleaner easier to move. Acces- sories (e.g. vacuum accessories) can be fi xed to the push handle batten (2.9). - An air blast is obtained by inserting a suc-
clean fi lter element Electronic monitoring system malfunc- tioning - Call Festool customer service for adjust-
tion hose in the blast opening (2.7).
ment

Wet suction - Functional safety not impaired; no action
8 Accessories, fi lter The accessory and fi lter order number can be found in your Festool catalogue or on the Internet under “www.festool.com”
6 After fi nishing work - Switch off the cleaner and pull the Plug of
9 Warranty Our equipment is under warranty for at least 12 months with regard to material or production faults in accordance with na- tional legislation. In the EU countries, the warranty period is 24 months (an invoice or delivery note is required as proof of purchase). Damage resulting from, in par- ticular, normal wear and tear, o-verloading, improper handling, or caused by the user or other damage caused by not following the operating instructions, or any fault ac- knowledged at the time of purchase, is not covered by the warranty. Damage caused by the use of non-original accessories and consumable material (e.g. sanding pads) is also excluded. Complaints will only be acknowledged if the equipment has not been dismantled before being sent back to the suppliers or to an authorised Festool customer support workshop. Store the operating instructions, safety notes, spare parts list and proof of purchase in a safe place. In addition, the manufacturer‘s current warranty conditions apply.
the mains lead out of the Plug socket. - Wind up the mains lead (2.6). - Empty dirt tank. - Clean the vacuum cleaner inside and out-
side by suction and wiping. - Deposit the appliance in a dry room, safe
from unauthorised use.
7 Maintenance and care
Always remove the power supply plug from the socket before carrying out any work on the machine.
All maintenance and repair work which requires the motor casing to be opened may only be carried out by an authorised service centre. A safety test is to be carried out at least once a year by the manufacturer or an instructed person, e.g. for possible dam- age to the fi lter and leaks in the appliance, and to ensure that the control devices are functioning. If the user services the appliance, it must be dismantled, cleaned and serviced, as far as possible without any danger to the mainte- nance staff and other persons. Appropriate measures include decontamination before dismantling, locally fi ltered forced ventila- tion on the dismantling site, cleaning the service area, and suitable personal safety equipment.
necessary
I possessori del prodotto e il nostro team di solito rispondono entro 24 ore, e la tua domanda sarà utile anche ad altri.
Invia la prima domanda: risponderanno altri possessori o il nostro team.