Marine Air Conditioner Operating manual 3

Dometic MCS15 — EN diagram (page 1)
Fig. 2

EN

Bootsklimaanlage Bedienungsanleitung 37

DE

Marine Climate System Notice d’utilisation 77

FR

Marine Climate System Istruzioni per I’uso 117

IT

Marine Climate System Instrucciones de uso 155

ES

Marine Climate

Marine Climate System Gebruiksaanwijzing 193

NL

System MCS5, MCS15

Klimatanläggning för båtar Bruksanvisning 229

SV

Page 2 of the Dometic MCS15 user manual — EN
Pagina 2 · clicca per ingrandire
Pagina 2
Dometic MCS15 — EN diagram (page 2)
Fig. 3
Page 4 of the Dometic MCS15 user manual — 1 Notes on using the manual
Pagina 4 · clicca per ingrandire
Pagina 4
Dometic MCS15 — 1 Notes on using the manual diagram (page 4)
Fig. 4 · 1 Notes on using the manual

1 Notes on using the manual

d

➤ ActionThis symbol indicates that action is required on your part. The

required action is described step-by-step.

✓This symbol describes the result of an action.

fig. 1 5, page 3: This refers to an element in an illustration. In this case, item 5 in figure 1 on page 3.

Please observe the following safety instructions.

Page 5 of the Dometic MCS15 user manual — 4 Proper use
Pagina 5 · clicca per ingrandire
Pagina 5
Dometic MCS15 — 2 Safety instructions diagram (page 5)
Fig. 5 · 2 Safety instructions

2 Safety instructions

The manufacturer will not be held liable for claims for damage resulting from the following:

z Faulty assembly or connection

z Damage to the appliance resulting from mechanical influences and

z Alterations to the device without express permission from the manu-

z Use for purposes other than those described in the operating manual

2.1 General safety

z Electronic devices are not toys!

Keep electrical appliances out of reach from children or infirm persons. Do not let them use the appliances without supervision.

z Persons (including children) whose physical, sensory or mental capabili-

ties or lack of experience and knowledge prevents them from using the appliance safely should not use this appliance without initial supervision or instruction by a responsible person.

z Use the device only as intended.

z Do not make any alterations or conversions to the device.

z Installation and repairing of the air conditioner may only be carried out by

qualified personnel who are familiar with the risks involved and the rele- vant regulations. Inadequate repairs can lead to considerable hazards. For repair service, please contact the service centre in your country (addresses on the back).

3 Target group for this manual

This operating manual is for air conditioner users.

4 Proper use

The Marine Climate System is an air conditioning system designed for use on boats or yachts. It can cool down or warm up the interior of the boat or yacht.

excess voltage · facturer

Page 6 of the Dometic MCS15 user manual — 6.1 Control Panel
Pagina 6 · clicca per ingrandire
Pagina 6
Dometic MCS15 — 5 Technical description diagram (page 6)
Fig. 6 · 5 Technical description

5 Technical description

The Marine Climate Systems MCS5 and MCS15 are marine air conditioners which can be used for variable air conditioning inside a boat or a yacht. They can cool and warm the room.

The Marine Climate System consists mainly of the air conditioning unit and a control panel. A refrigerant gas is circulating through the system which is sea- water cooled.

6 Operating elements

6.1 Control Panel

Key to fig. 1, page 2:

1 Power Button Press and release to toggle between the On and Off Modes.

2 Fan Button Press to advance through the available fan settings. “1“(lowest) through “6“ (highest) indi- cates Manual Fan Speeds. The letter ”a” indicates automatic fan operation selected.

3 Down Button Press and release to display the set point. Press and hold the Down Button to decrease the set point. Set point is decreased one degree each time the button is depressed.

4 Faceplate sensor The faceplate sensor will read the room temperature unless a remote air sensor is installed.

5 Up Button Press and release to display the set point. Press and hold the Up Button to increase the set point. Set point is increased one degree each time the button is depressed.

Item Name Description

Page 7 of the Dometic MCS15 user manual — 6.2 Dual Button Functions
Pagina 7 · clicca per ingrandire
Pagina 7
Dometic MCS15 — 6.2 Dual Button Functions diagram (page 7)
Fig. 7 · 6.2 Dual Button Functions

6 Display The inside air temperature is displayed when the control is on. The set point is displayed when either Up or Down Button is pressed. The display also indicates program information and fault codes. When the control resumes operation after a power interruption all the display LEDs will turn on for one second. This is normal operating condition and is referred to as Power On Reset.

7 LED “Heat Mode” This LED is lit when – the Heat Only Mode is selected – or the unit is in a heating cycle.

8 LED “Fan Indicator” This LED is lit when a Manual Fan Speed is selected.

9 LED “Cool Mode” This LED is lit when – the Cool Only Mode is selected – or when the unit is in a cooling cycle.

6.2 Dual Button Functions

Up and Down Buttons

z While in the On Mode: Simultaneously press the Up and Down Buttons

to display outside air temperature providing the optional outside air tem- perature sensor is installed.

z While in the Program Mode: Simultaneously press the Up and Down

Buttons to set new program defaults.

Power and Down Buttons

z While viewing the service fault history log: Simultaneously press the

Power and Down Buttons to clear the fault history log (see chapter “Service History Log” on page 14).

z While in the On Mode: Simultaneously press the Power and Down

Buttons to enter the Moisture Mode (see chapter “Moisture Mode” on page 11).

Page 8 of the Dometic MCS15 user manual — 7.2 Overview
Pagina 8 · clicca per ingrandire
Pagina 8
Dometic MCS15 — 7 Operating diagram (page 8)
Fig. 8 · 7 Operating

7 Operating

7.1 Initial startup a

➤Ensure seawater intake ball valve (seacock) is open.

➤Make sure the control is powered OFF.

➤Turn on air conditioner circuit breaker.

➤If the seawater pump has its own circuit breaker, turn that on too.

➤Press the Fan Button (fig. 1 2, page 2).

✓This energizes the fan.

➤Verify that the fan is running and that there is steady airflow out of the sup-

ply-air grille.

✓Select a temperature set point lower than the current cabin temperature.

✓This starts the compressor and seawater pump.

➤Check for a steady solid stream of seawater from the overboard

discharge.

➤If the unit does not appear to be operating properly, refer to trouble-

shooting guidelines (chapter “Troubleshooting” on page 24).

7.2 Overview

➤Press the Power button (fig. 1 1, page 2) once to engage the system.

✓The display indicates room temperature when the system is on and is

blank when the system is off.

Power On

Page 9 of the Dometic MCS15 user manual — 7.3 Modes of Operation
Pagina 9 · clicca per ingrandire
Pagina 9
Dometic MCS15 — 7.3 Modes of Operation diagram (page 9)
Fig. 9 · 7.3 Modes of Operation

➤Press the Up or Down button (fig. 1 3 and 4, page 2) to set the desired

room temperature. The set point can be viewed by momentarily pressing and releasing the Up or Down button.

Fan-speed operation is automatic, allowing fan speed to decrease as the set point temperature is approached in the Cool Mode. The fan operates at low speed when set point is satisfied.

➤Use the Fan button (fig. 1 2, page 2) to select manual fan speeds.

You can program the fan to run only when cooling or heating is required. Nor- mally the automatic fan-speed operation is reversed in the Heating Mode, however, the fan can be programmed to operate the same as in the Cooling Mode.

The control’s nonvolatile memory requires no batteries or backup power. When power is lost, the operating parameters are retained indefinitely. When power is restored, the control resumes operating as last programmed.

7.3 Modes of Operation

When the Marine Climate System is in the Off Mode, all control outputs are turned off. Program parameters and user settings are saved in nonvolatile memory.

When the Marine Climate System is in the On Mode, power is supplied to the appropriate outputs and the display indicates the current state of operation. The operating and program parameters resume based on those stored the last time the unit was operating.

When Cool Mode is selected, the Cool Mode LED is lit and the cooling systems are operated as required. When the temperature drops below the set point, the system will not automatically switch to the Heat Mode.

Show 6 more labels / short text on this page
Set Temperature · Fan Speed · Memory · Off Mode · On Mode · Cool Mode
Page 10 of the Dometic MCS15 user manual — 7.3 Modes of Operation
Pagina 10 · clicca per ingrandire
Pagina 10
Dometic MCS15 — 7.3 Modes of Operation diagram (page 10)
Fig. 10 · 7.3 Modes of Operation

When the Heat Mode LED is lit, only the heating systems are selected and operated as required. Should the temperature rise above the set point, the system will not automatically switch to the Cool Mode.

Automatic Mode provides both heating and cooling as required. The Heat or Cool LED will be lit according to the mode required.

Temperature in a given mode is maintained within 2 °F (1.1 °C) of set point, however a 4 °F (2.2 °C) difference is required to allow the Marine Climate System to change modes.

Once the mode changes temperature will be maintained within 2 °F (1.1 °C) of set point.

Manual Fan Mode allows to select the desired fan speed manually. When a manual fan speed has been selected, the Fan LED will be lit. Manual Fan Mode is sometimes preferred when room temperature is constantly changing due to varying heat loads.

The fastest fan speed is represented by “6”, the slowest represented by “1”.

➤Press and hold the Fan Button during normal operation to select one of

the six manual fan speeds available.

When the system is off at the control panel the fan can be used to only circulate the air.

➤Press and hold the Fan Button when the display is off until the desired

speed number appears in the window.

➤Release the Fan Button

✓The fan will run at the selected speed circulating the air without heating or

cooling.

➤Press the Power Button once to cancel the Circulation Mode and enter the

On Mode.

Show 4 more labels / short text on this page
Heat Mode · Automatic Mode · Manual Fan Mode · Circulation Mode
Page 11 of the Dometic MCS15 user manual — Program Mode I
Pagina 11 · clicca per ingrandire
Pagina 11
Dometic MCS15 — Program Mode I diagram (page 11)
Fig. 11 · Program Mode I

➤While in the On Mode simultaneously press the Power and Down Buttons.

✓The first cycle will start in one minute.

➤Press the Power Button to end the Moisture Mode.

✓The “HU1” mnemonic code is displayed while in the Moisture Mode.

Program Mode I

The Program Mode is used to adjust the systems operating parameters to suit the particular needs of individual users. The Program Mode is also used to tailor the air conditioning system for the most efficient operation within an installation.

Variables such as ducting, sensor location and system layout affect the system operation. The Marine Climate System is shipped with factory default settings which are stored in permanent memory and can be recalled at any time.

Moisture Mode

Page 12 of the Dometic MCS15 user manual — 7.4 Operating the Marine Climate System a
Pagina 12 · clicca per ingrandire
Pagina 12
Dometic MCS15 — 7.4 Operating the Marine Climate System a diagram (page 12)
Fig. 12 · 7.4 Operating the Marine Climate System a

7.4 Operating the Marine Climate System a

➤Press the Power Button (fig. 1 1, page 2) shortly to engage the system.

✓The display indicates room temperature when the system is on and is

blank when the system is off.

➤Press the Down Button (fig. 1 3, page 2) or Up Button (fig. 1 5, page 2)

to choose the desired set point.

✓The display indicates room temperature when the system is on and is

blank when the system is off.

✓The thermostat is now set to maintain a constant temperature.

➤Set the desired room temperature by pressing the Up or Down Button.

The set point can be viewed by momentarily pressing and releasing the Up or Down Button.

The Marine Climate System has nonvolatile memory requiring no batteries or backup power. When power is lost the operating parameters are retained in- definitely. When power is restored, the Marine Climate System resumes op- erating as last programmed.

Automatic fan speed operation allows fan speed to decrease as room tem- perature is approached in the Cool Mode. The fan will operate at low speed when set point is satisfied.

Manual fan speeds can be selected with the Fan Button.

The fan can be programmed to run only when cooling or heating is required. Normally the automatic fan speed operation is reversed in the Heating Mode, however, the fan can be programmed to operate the same as in the Cooling Mode.

Page 13 of the Dometic MCS15 user manual — 7.5 Automated Factory Self Test Program
Pagina 13 · clicca per ingrandire
Pagina 13
Dometic MCS15 — 7.5 Automated Factory Self Test Program diagram (page 13)
Fig. 13 · 7.5 Automated Factory Self Test Program

7.5 Automated Factory Self Test Program

The Marine Climate System software provides a self test program to facilitate factory testing of the entire air conditioning system. Once the self test pro- gram is activated, the test cycle will continue until the AC power is interrupted or the Power Button is pressed once which returns the system to the Off Mode.

➤Activate the self test program by pressing the Power Button while turning

on the AC power.

➤Release the Power Button while the display indicates “888” and all LEDs

are lit.

✓The Marine Climate System is now in the self test program.

✓“tSt” appears in the display while in the self test program.

Once activated the self test software will continuously execute the following procedure:

z Turn on in the Heat Mode and supply heating for 10 min.

z Stop heating and run the fan only for 5 min.

z Switch to Cool Mode and continue cooling for 10 min.

z Stop cooling and run the fan only for 5 min.

z Return to step one and continue until interrupted.

The self test program will continue until the power is interrupted or the test is halted by pressing the Power Button once.

Page 14 of the Dometic MCS15 user manual — 7.6 Service Tools
Pagina 14 · clicca per ingrandire
Pagina 14
Dometic MCS15 — 7.6 Service Tools diagram (page 14)
Fig. 14 · 7.6 Service Tools

7.6 Service Tools

Total compressor cycle time is saved in EEPROM every six minutes of con- tinuous compressor running time. Cycles less than six minutes are discarded to conserve memory and allow the most flexible hour-meter possible.

To view the hour meter proceed as follows:

➤Turn off the AC power.

➤Press the Down Button and hold it.

➤Restore AC power.

✓After Power-On Reset is complete, the following appears in the display:

– “Hr” is displayed for one second. – The display blanks out for one second then displays the thousands of hours for three seconds. – The display blanks out for one second then displays the hundreds units for three seconds.

✓The unit returns to the last operating state before power was removed.

Maximum recorded time is 65,536 hours, the meter stops and can only be reset by a service technician.

The Marine Climate System records and remembers the eight most recent faults. Each time a fault is detected, a one hour timer is started.

Three consecutive faults within that hour cause system shut down, lock out and display the fault code. During that hour, to conserve memory, the same recurring fault is not recorded in the service history log. Continuous operation for one hour without the same recurring fault clears that fault counter but the event remains in the service history log until overwritten. Should a different fault be detected during the hour, it will be entered into the service history log.

The following events are entered into the service history log:

z High Freon Pressure

z Low Freon Pressure

z Air Sensor Fault

Hour Meter · Service History Log

Page 15 of the Dometic MCS15 user manual — 8.2 Changing Program Parameters
Pagina 15 · clicca per ingrandire
Pagina 15
Dometic MCS15 — 8 Programming diagram (page 15)
Fig. 15 · 8 Programming

To view the service history log proceed as follows:

➤Turn off the AC power.

➤Press the Fan Button and hold it.

➤Turn on the AC power.

➤Once Power On Reset is completed (display indicates “888” and all LEDs

are lit) release the Fan Button.

✓The display will flash the most recent fault detected, followed by the event

chronology number.

➤To view other events detected press either the Up or Down Button.

➤To clear the service history log simultaneously press the Power and Down

Buttons.

➤To exit the service history log

– press either the Power, the Up or the Down Buttons or – wait thirty seconds without pressing any button.

8 Programming

8.1 Entering Program Mode

➤Press and hold the Power Button while in the Off Mode until the letter “P”

appears in the display.

✓The characters “P1” followed by the parameter setting, appear in the

display.

✓ The Marine Climate System is now in the Program Mode. I

8.2 Changing Program Parameters

➤Increment from one program parameter to the next by pressing the Fan

Button.

➤Press the Up and Down Buttons to select the data or set the desired limits

for the parameter being programmed.

Page 16 of the Dometic MCS15 user manual — 8.5 Software Identification
Pagina 16 · clicca per ingrandire
Pagina 16
Dometic MCS15 — 8.3 Saving New Program Parameters I diagram (page 16)
Fig. 16 · 8.3 Saving New Program Parameters I

8.3 Saving New Program Parameters I

➤Simultaneously press the Up and Down Buttons to save the new program

parameters.

✓This will set the new program defaults.

8.4 Exiting the Program Mode

There are two methods to exit the Program Mode.

➤Press the Power Button

✓The Marine Climate System will return to the Off Mode.

➤Do not press any buttons and do not attempt any program changes for

one minute.

✓The Marine Climate System will exit the Program Mode.

8.5 Software Identification

The software version of the Marine Climate System is identified for one sec- ond prior to the exit from the Program Mode. The software identification number, e.g. (“A12”) will appear in the display for one second, then the Ma- rine Climate System will return to the Off Mode. I

… or

Page 17 of the Dometic MCS15 user manual — 8.7 Programmable Parameters
Pagina 17 · clicca per ingrandire
Pagina 17
Dometic MCS15 — 8.6 Restore Memorized Default Settings diagram (page 17)
Fig. 17 · 8.6 Restore Memorized Default Settings

8.6 Restore Memorized Default Settings

The memorized default settings can be restored as follows.

➤Enter the Program Mode.

➤Set P-17 to “rSt”.

➤Exit the Program Mode.

✓The software version number (e.g. “A12”) appears in the display.

✓The memorized default settings are restored and the Marine Climate Sys-

tem returns to the Off Mode.

8.7 Programmable Parameters

Dometic MCS15 — 8.7 Programmable Parameters diagram (page 17)
Fig. 18 · 8.7 Programmable Parameters

1 = On with 5 °F faceplate sensor differential

2 = On with 7 °F faceplate sensor differential

Programmable Parameters Table

Page 18 of the Dometic MCS15 user manual — 8.6 Restore Memorized Default Settings
Pagina 18 · clicca per ingrandire
Pagina 18
Dometic MCS15 — 8.6 Restore Memorized Default Settings diagram (page 18)
Fig. 19 · 8.6 Restore Memorized Default Settings

P-11 Display ºF or ºC F F = Fahrenheit displayed

P-15 Reverse Cycle Heating or Electric Heat Only Option Installed (cool- ing only units)

P-16 Fan Motor type selec- tion Shaded Pole or Split Capacitor.

Page 19 of the Dometic MCS15 user manual — 8.6 Restore Memorized Default Settings
Pagina 19 · clicca per ingrandire
Pagina 19
Dometic MCS15 — 8.6 Restore Memorized Default Settings diagram (page 19)
Fig. 20 · 8.6 Restore Memorized Default Settings
P-1Operating Mode

The following operating modes can be selected:

z Automatic Mode by selecting “0”

z Cool Only Mode by selecting “1”

z Heat Only Mode by selecting “2”.

P-2High Fan Limit

The upper fan speed limit can be adjusted for various motors. The high fan limit is adjusted with the system installed and operating. The values range from 65 through 95, arbitrary units.

➤Use the Up and Down Buttons to select the desired speed.

– Increase the number for a higher fan speed. – Decrease the number to lower the fan speed.

P-3Low Fan Limit

The low fan limit determines the lowest output allowed for the low fan speed. The values range from 30 through 64, arbitrary units.

➤Use the Up and Down Buttons to select the low fan limit.

– Increase the number for a higher fan speed. – Decrease the number to lower the fan speed. a

P-4Compressor Staging Time Delay

The compressor staging delay is provided for installations where more than one system operates from the same power source. Setting different staging delays allows compressors to start at different times when power is inter- rupted.

Units should be staged 5 s apart. The minimum delay is 5 s and the maxi- mum is 135 s.

Page 20 of the Dometic MCS15 user manual — 8.6 Restore Memorized Default Settings
Pagina 20 · clicca per ingrandire
Pagina 20
Dometic MCS15 — 8.6 Restore Memorized Default Settings diagram (page 20)
Fig. 21 · 8.6 Restore Memorized Default Settings
P-5Temperature Calibration

Use this feature to calibrate the ambient sensor.

➤Select P-5.

✓The ambient temperature appears in the display.

➤Use the Up and Down Buttons to set the correct reading.

✓The temperature in the display will increase or decrease as required.

P-6Failsafe Level

There are four failsafe levels (see chapter “Failsafe and Fault Handling Codes” on page 27).

P-7Low AC Voltage Shutdown

Use this feature to shut down the unit if the voltage drops to a dangerously low level.

By default it is off, but it can be set from 175 – 205. This feature works imme- diately at start up, but while running will require a 5 min delay before display- ing a fault to prevent nuisances.

The fault code is “LAC”.

P-8De-Icing Cycle

The Marine Climate System is equipped with a de-icing cycle to prevent ice build up on the evaporator coil during extended periods of cooling operation. Installation variables such as grille sizes, length of ducting, insulation R fac- tors and ambient temperatures determine the cooling run time required to achieve set point. Customer usage may substantially increase run times by operating the system with the hatches and doors open.

Programming an unrealistic set point (e.g. 65 °F/18.3 °C) and leaving the salon door open will usually cause the evaporator to ice up on warm humid days.

De-icing is accomplished by using an algorithm that closely monitors the room air temperature in repeating 10 min intervals during a cooling cycle.

Page 21 of the Dometic MCS15 user manual — 8.6 Restore Memorized Default Settings
Pagina 21 · clicca per ingrandire
Pagina 21
Dometic MCS15 — 8.6 Restore Memorized Default Settings diagram (page 21)
Fig. 22 · 8.6 Restore Memorized Default Settings

The de-icing feature has two different, selectable behavior modes when it is used in conjunction with the control panel’s built-in room air temperature sen- sor. It attempts to compensate for any temperature discrepancy that the face- plate sensor may experience. Although this discrepancy is not typical, installation variables such as where the control panel is placed inside the room (e.g. near an open door or in direct sunlight) can affect how accurately it can read the actual room temperature.

By default with P-8 set to “1” (ON), the algorithm is applied assuming the faceplate sensor may be reading the room temperature as much as 5 °F (2.8 °C) greater than the actual evaporator temperature.

With programmable parameter P-8 set to “2”, the temperature differential that is applied to the faceplate sensor reading is increased to 7 °F (3.9 °C) for even more extreme installations. Setting P-8 to “2” should only be used if a setting of “1” does not prevent evaporator ice from forming.

Alternately, the installation of an optional alternate air temperature sensor (located in the return air path) will greatly increase the effectiveness of the de-icing feature, and this option should be considered whenever the face- plate sensor cannot read the room temperature accurately.

P-9High Water Temperature Limit

Use this feature to shut down the unit if the water in condenser coil rises to a dangerously high level.

By default it is off, but it can be set between 100 and 150 °F.

The fault code is “PLF”.

P-10Display Brightness Control

The display brightness can be adjusted from 4 (dimmest) to 13 (brightest).

P-11Fahrenheit or Celsius Selection

The default setting is “°F”. Select “°C” for Celsius. Celsius readings are dis- played in tenths, e.g. 22.2°.

P-12Cycle Pump With Compressor

The pump can also be programmed to operate continuously or cycle on de- mand.

➤To program continuous operation select “On”.

Page 22 of the Dometic MCS15 user manual — P-16: Fan Motor Selection a
Pagina 22 · clicca per ingrandire
Pagina 22
Dometic MCS15 — ➤ To cycle the fan with the compressor select “CYC”. a diagram (page 22)
Fig. 23 · ➤ To cycle the fan with the compressor select “CYC”.…
P-13Reverse Automatic Fan Speeds During Heating

The automatic fan speeds can be reversed during Heating Mode. The fan will speed up as the set point is approached. Lowering the fan speed when the cabin is cold increases head pressure and helps raise supply temperature. The fan switches to low speed when the set point is satisfied and the com- pressor cycles off.

Normal fan operation is represented by “nor”.

➤To reverse fan speeds in heating, select “rEF”.

P-14Cycle Fan with Compressor

The fan can be programmed to run continuously when the system is on or can be allowed to cycle with the compressor.

The default is “con”, continuous fan.

➤ To cycle the fan with the compressor select “CYC”. a

P-15Reverse Cycle or Electric Heat

➤Do not change the default parameter.

P-16: Fan Motor Selection a

➤Select “SC”.

➤Save this change as a new default by simultaneously pressing and releas-

ing the Up and Down Buttons prior to exiting the program mode.

➤Make note of new default in the Programmable Parameters table for

future reference and servicing.

Page 23 of the Dometic MCS15 user manual — ➤ To cycle the fan with the compressor select “CYC”. a
Pagina 23 · clicca per ingrandire
Pagina 23
Dometic MCS15 — ➤ To cycle the fan with the compressor select “CYC”. a diagram (page 23)
Fig. 24 · ➤ To cycle the fan with the compressor select “CYC”.…
P-17Reset Memorized Defaults

The default programming parameters can be reset as follows:

➤Select “rSt”.

✓This restores the programmable parameters to the default values.

The default parameters listed in the chapter “Programmable Parameters Table” on page 17 may be altered by the installing dealer or end user. Once new defaults are entered and memorized the factory defaults will be over- written. The original factory program parameters as listed in the table may be restored manually.

P-18, P-19Reserved for Future Option
P-20Filter Threshold

This feature is to remind you to change the air filter on a unit. The units are x10 hours.

By default it is off, which is designated with a “00”, but it can be set between 100 and 2500 hours. After the unit has reached its threshold time, it will dis- play a “FIL” remind 1 s every 10 s.

P-21Current Filter Time

This feature is used to display the amount of time the current filter has been on the unit. The units are x10 hours.

➤In order to reset this parameter, simply press the Up or Down Button.

P-22Voltage Calibration

This feature displays the voltage reading as seen by the display. Calibrating this parameter will provide a more accurate voltage when calculating low voltage for P-7. It will display a live reading of the voltage.

➤Manipulate the reading by pressing the Up or Down Button.

Page 24 of the Dometic MCS15 user manual — 9.1 General Troubleshooting
Pagina 24 · clicca per ingrandire
Pagina 24
Dometic MCS15 — 9 Troubleshooting diagram (page 24)
Fig. 25 · 9 Troubleshooting

9 Troubleshooting

9.1 General Troubleshooting

Problem Possible Reason Solution

System will not start. Air conditioning unit circuit breaker is off.

Turn circuit breaker on at ship’s panel.

Control is not turned on. Turn control on.

Wrong wiring at terminal strip. Check wiring diagram and correct if necessary.

Push-on butt connectors became disconnected during installation.

Disconnect power supply and open electric box.

Check wiring diagram, correct if necessary.

Input line voltage is insufficient. Check power source (shore/gen- erator) for proper voltage.

Check wiring and terminals for proper sizes and connections.

Verify with a volt-meter that the power at the unit is the same as the power source.

Fan is not running. – See corresponding section in chapter “Control Panel Trouble- shooting” on page 29.

No cooling or heating. Temperature set point is satisfied. Lower or raise set point.

Obstructed seawater flow. Clean seawater strainer.

Check for obstructions at speed scoop thru-hull inlet.

Check for a good steady flow from the overboard discharge.

Seawater pump may be air- locked.

Remove hose from pump dis- charge to purge air from line.

Loss refrigerant gas. Check air conditioning unit for refrigerant oil leakage.

Call service technician.

Page 25 of the Dometic MCS15 user manual — 9 Troubleshooting
Pagina 25 · clicca per ingrandire
Pagina 25
Dometic MCS15 — 9 Troubleshooting diagram (page 25)
Fig. 26 · 9 Troubleshooting

No cooling or heating (contn’d).

Seawater temperature too high for cooling or too low for heating.

Seawater temperature will directly affect air conditioning unit’s efficiency.

This air conditioning unit can effectively cool your boat in water temperature up to 90 °F (32.2 °C) and heat in water temperatures as low as 40 °F (4.4 °C).

Fan coil is iced (in cooling). See below.

Fan is not running. See corresponding section in chapter “Control Panel Trouble- shooting” on page 29.

Seawater plumbing is air-locked. Ensure that seawater plumbing is installed per the guidelines in the Installation Manual.

The Marine Climate System is programmed for Cool or Heat only, or mechanical control ther- mostat is rotated too far towards either Cooler or Warmer setting.

Set P1 to the desired value or rotate the mechanical control thermostat.

High pressure switch open (in cooling) due to improper sea- water flow.

Check seawater hose for kinks or collapses.

Verify pump operation.

Strainer or intake may be plugged, seacock may be closed.

Check pump circuit breaker if applicable.

High pressure switch open (in heating) due to improper airflow.

Remove any obstructions in return air stream.

Clean return air filter and grille.

Check for crushed or restricted ducting (ducting must be as straight, smooth and taut as possible).

High-pressure switch is open in heating mode.

System may cycle on high-pres- sure if seawater temperature is above 55 °F (12.8 °C).

Compressor’s thermal overload is open due to either of the above reasons.

Compressor needs to cool down.

Turn system off for a while (it may take up to three hours to reset thermal overload).

No cooling Control panel may not be in “cool” position.

Reset control panel.

Coil iced. See below.

Page 26 of the Dometic MCS15 user manual — 9 Troubleshooting
Pagina 26 · clicca per ingrandire
Pagina 26
Dometic MCS15 — 9 Troubleshooting diagram (page 26)
Fig. 27 · 9 Troubleshooting

No heating. Unit is “cool only”, or if reverse cycle, reversing valve may be stuck.

Tap reversing valve lightly with rubber mallet while unit is in heat mode.

Call for service if that does not correct the problem.

Low airflow. Airflow is blocked. Remove any obstructions in return air stream.

Clean return air filter and grille.

Check for crushed or restricted ducting, ducting must be as straight, smooth and taut as pos- sible.

Fan Coil is iced. See below.

Fan coil is iced. Thermostat set point is too low. Check setting on control panel.

If setting is extreme for condi- tions, raise set point until unit cycles off to give coil time to thaw.

Improper airflow. Remove any obstructions in return air stream.

Clean return air filter and grille.

Check for crushed or restricted ducting.

Ducting run must be as straight as possible; remove any excess ducting.

See the chapter “Control Panel Troubleshooting” on page 29 for reprogramming options.

Supply air is short-cycling. Redirect supply air so that is not blowing into the return air stream.

Seal any air leaks on duct.

Humidity level too high. Close hatches and doors.

When all else fails. Switch air conditioning unit to heat until ice melts or use hair dryer to melt.

Water coil is iced in the Heating Mode.

Seawater temperature is below 40 °F (4.4 °C). Shut down system to prevent damage to condenser.

Allow coil to defrost.

Page 27 of the Dometic MCS15 user manual — is enabled). I
Pagina 27 · clicca per ingrandire
Pagina 27
Dometic MCS15 — 9.2 Failsafe and Fault Handling Codes diagram (page 27)
Fig. 28 · 9.2 Failsafe and Fault Handling Codes

System runs continuously.

Set point temperature is improp- erly set: too low for cooling or too high for heating.

Raise or lower set point.

Porthole or hatches open. Close all port holes and hatches.

Seawater temperature too high for cooling or to low for heating.

Seawater temperature will directly affect the air conditioning unit’s efficiency.

This air conditioning unit can effectively cool your boat in water temperatures as low as 40 °F (4.4 °C) and heat (if reverse cycle option is installed) in water up to 90 °F (32.2 °C).

Improper air sensor location. See corresponding section in chapter “Control Panel Trouble- shooting” on page 29.

Cold supply air returning directly to return air grille.

Redirect supply air so that it is not directed into the return air stream.

9.2 Failsafe and Fault Handling Codes

When a fault is detected the Marine Climate System will display one of the following Mnemonic fault codes:

z “ASF”: Indicates Air Sensor Fault.

z “FIL”: Indicates filter needs replacing (if this option is enabled).

z “HPF”: Indicates High Freon Pressure.

z “LAC”: Indicates Low AC voltage (if this option is enabled).

z “LPF”: Indicates Low Freon Pressure (Not applicable to MCS models).

z “PLF”Indicates high water temperature in condensing coil (if this option

is enabled). I

Short cycling compressor

Page 28 of the Dometic MCS15 user manual — 9.2 Failsafe and Fault Handling Codes
Pagina 28 · clicca per ingrandire
Pagina 28
Dometic MCS15 — 9.2 Failsafe and Fault Handling Codes diagram (page 28)
Fig. 29 · 9.2 Failsafe and Fault Handling Codes

Only “ASF” detected and displayed.

The Marine Climate System will shut down and will not restart until the fault is repaired.

Once the fault is repaired the Marine Climate System will restart.

All actions in level 0 plus all other faults detected but not indicated.

The system shuts down for 2 min or until the fault is cleared, whatever is longer.

The system will restart if the fault is cleared.

All actions same as level 0 and 1. Faults are indicated.

The system shuts down for 2 min or until the fault is cleared, whatever is longer.

All actions the same as level 0, 1 and 2.

The system shuts down for 2 min or until the fault is cleared, whatever is longer.

The system will lockout after four consecutive “HPF” or “LPF” faults.

To clear the lockout:

➤Pressing the Power Button once to Off Mode.

➤Pressing the Power Button again to On Mode.

Show 4 more labels / short text on this page
Failsafe Level 0 · Failsafe Level 1 · Failsafe Level 2 · Failsafe Level 3
Page 29 of the Dometic MCS15 user manual — 9.3 Control Panel Troubleshooting
Pagina 29 · clicca per ingrandire
Pagina 29
Dometic MCS15 — 9.3 Control Panel Troubleshooting diagram (page 29)
Fig. 30 · 9.3 Control Panel Troubleshooting

9.3 Control Panel Troubleshooting

Problem Possible Reason Solution

Control panel is not lit. 8-pin display cable plugs are not

Power off at the circuit breaker.

making contact (unplugged, dirty, bent, or broken pins).

Remove connector and inspect.

If damaged, replace connector or entire display cable.

Fan is not running or runs continuously.

The Marine Climate System is programmed for either fan cycling with compressor or continuous fan operation.

Reprogram parameter P-14.

Fan is not running but the compressor is.

Failed triac on control panel circuit board.

Send for repair or call local service technician.

Fan runs continu- ously although it is set to cycle with compres- sor.

Failed triac on control panel circuit board.

Send for repair or call local service technician.

No cooling or heating. The Marine Climate System is programmed for heat or cool only.

Reprogram parameter P-1.

“HPF” or “LPF” is displayed. See below.

No heat. The Marine Climate System may be set to Electric Heat, not Reverse Cycle.

Reprogram parameter P-15.

Unit switches to heat while in Cool Mode.

De-icing feature enabled due to coil icing up.

Fan coil is iced. Improper airflow. See corresponding section in chapter “General Troubleshoot- ing” on page 24, before repro- gramming the Marine Climate System.

Reprogram parameter P-8 to enable de-icing.

If de-icing cycle does not melt ice, switch air conditioning unit to heat until ice melts or use hair dryer to melt ice.

If problem persists, reprogram Low Fan Speed Limit for maxi- mum value: Set P-3 to 64.

Reprogram parameter P-8

Page 30 of the Dometic MCS15 user manual — 9.3 Control Panel Troubleshooting
Pagina 30 · clicca per ingrandire
Pagina 30
Dometic MCS15 — 9.3 Control Panel Troubleshooting diagram (page 30)
Fig. 31 · 9.3 Control Panel Troubleshooting

System runs continuously.

Improper air sensor location. Verify display head location.

Install alternate air sensor if necessary.

Unrealistic set point. Adjust set point until unit cycles off.

“ASF” (Air Sensor Failure) is displayed.

Indicates failed face plate air sensor, alternate air sensor or display cable.

Unplug alternate air sensor if installed or plug in alternate air sensor if not installed.

Try another display cable.

Damaged jack/socket in display head or on circuit board.

Visually check to see that pins inside socket are not bent or corroded.

Repair or replace display or circuit board if needed.

“FIL” (Filter Replace- ment) is flashing.

Filter needs replacement. Replace filter.

Reset P-21 to “00”.

“HPF” (High Freon Pressure) is displayed.

High-pressure switch is open (in cooling) due to improper sea- water flow.

Check seawater hose for kinks or collapses.

Verify pump operation.

Strainer or intake may be plugged, seacock may be closed.

Check pump circuit breaker if applicable.

High-pressure switch open (in heating) due to improper airflow.

Remove obstructions in return air stream.

Clean air filter and grille.

Check for crushed or restricted ducting (ducting must be as straight, smooth and taut as possible).

– reprogram Low Fan Speed

Limit for maximum valueSet P-3 to “64”

– set the reverse fan speeds dur-

ing Heating Mode parameter P-13 to “rEF”, or manually set fan speed to high

“LAC” (Low AC Voltage) is displayed.

Supply voltage is too low. Verify power to unit with multi- meter.

Voltage is improperly calibrated. Verify that P-22 matches voltage reading to unit with a multimeter.

If problem persists,

Page 31 of the Dometic MCS15 user manual — 10.2 Seawater Strainer
Pagina 31 · clicca per ingrandire
Pagina 31
Dometic MCS15 — 10 Maintenance diagram (page 31)
Fig. 32 · 10 Maintenance

“LPF” (Low Freon Pressure) is displayed.

Low-pressure switch is open due to low seawater and/or low return air temperatures.

Try restarting the air conditioning unit, the optional low pressure switch has a ten minute shut- down time delay that may be in affect.

Low pressure switch is open due to loss of refrigerant.

Check air conditioning unit for refrigerant oil leakage.

Call service technician.

“PLF” (Low Pump Flow) is displayed.

Condenser coil is too hot. Verify that unit is getting water flow, and that condenser is not fouled.

Thermistor is damaged. Unplug water sensor if installed.

Try another if it is available.

Damaged jack/socket on circuit board.

Visually check to see that pins inside socket are not bent or cor- roded.

Repair or replace circuit board if needed.

10 Maintenance

10.1 Reversing Valve

The reversing valve must be energized periodically to keep the internal parts moving freely.

➤Switch the air conditioner unit into heat for a few seconds once a month.

10.2 Seawater Strainer

➤Ensure that your pump receives adequate seawater flow by regularly

cleaning the strainer basket.

➤Periodically check the overboard discharge for a steady stream of water.

➤Check seawater intake speed scoop for obstructions.

➤Make sure hoses are not looped, kinked or crushed.

Page 32 of the Dometic MCS15 user manual — 10.3 Condenser Coil Cleaning a
Pagina 32 · clicca per ingrandire
Pagina 32
Dometic MCS15 — 10.3 Condenser Coil Cleaning a diagram (page 32)
Fig. 33 · 10.3 Condenser Coil Cleaning a

10.3 Condenser Coil Cleaning a

Coils can become fouled over a period of time due to marine growth or scale build-up. This both obstructs water flow and prohibits proper heat transfer.

➤Turn off the system at the circuit breaker on the ship’s panel.

➤Disconnect the inlet and outlet connections of the condenser coil.

➤Place a strainer or piece of screen over the inlet of the pump.

➤Submerse the pump into a container filled with a 5 % solution of muriatic

or hydrochloric acid and fresh water or use a premixed over-the-counter solution. a

➤Use chemical resistant hoses (MAS white PVC 5/8"/16 mm I.D., etc.) to

connect the inlet of the condenser coil to the outlet of a chemical resistant, submersible pump (MAS P-500 pump, etc.) and let the hose connected to the coil outlet flow freely into the container. Use a large container as possible to hold the solution (19 – 95 l).

➤Power the pump and circulate the solution through the condenser coil for

15. 45 min, depending upon the size of the coils and the extent of the contamination. Visual inspection of the solution in the container should indicate when the contamination removal has stopped.

➤Circulate fresh water through the coil to flush any residual acid from the

system.

➤Restart the system.

➤Check operational parameters to ensure thorough cleaning has taken

place. Additional cleaning may be necessary with extreme contamination.

Page 33 of the Dometic MCS15 user manual — 10.5 Winterization I
Pagina 33 · clicca per ingrandire
Pagina 33
Dometic MCS15 — 10.4 Return Air Filters diagram (page 33)
Fig. 34 · 10.4 Return Air Filters

10.4 Return Air Filters

➤Check the return air filter about once a month and clean as necessary.

➤To clean the filter,

– remove it from the return-air grille, – rinse with water, – air dry and – reinstall.

➤If your kit is supplied with a filtered return-air grille, the filter attached to

the unit’s evaporator must be removed. Two filters are not better than one, as the reduced air flow will decrease performance and possibly freeze the evaporator coil.

10.5 Winterization I

Choose the method that works best for you. In the following four methods, the first two use a 50/50 nonpolluting biodegradable antifreeze/water solu- tion:

z Pumping of anti-freeze solution into the overboard thru-hull fitting, and

discharging through the intake thru-hull fitting until all water is flushed out and the solution no longer appears diluted.

z Use of the seawater pump to pump anti-freeze solution through the

system and discharging through the overboard thru-hull fitting until all wa- ter is flushed out and the solution no longer appears diluted: – Close seacock. – Remove hose from strainer discharge. – Raise hose above pump (so pump does not lose its prime). – Pour in antifreeze solution. – Pump solution through system. – Drain the strainer and hose to seacock of water.

Page 34 of the Dometic MCS15 user manual — wherever possible. M
Pagina 34 · clicca per ingrandire
Pagina 34
Dometic MCS15 — 11 Guarantee diagram (page 34)
Fig. 35 · 11 Guarantee

z Use of pressurized air injected at the overboard discharge fitting and the

water being discharged through the seawater intake fitting.

z Use of pressurized air to force water from the intake through the over-

board discharge.

Any method that causes the antifreeze solution to flow downward is the method of choice. By this means, the antifreeze solution will displace any water trapped and eliminate the possibility of freezing in hidden areas.

In addition, since the seawater pump utilizes a magnetically driven impeller:

z Remove the impeller from the wet end assembly.

z Wipe the impeller with an alcohol solution.

z Store the impeller in a warm, dry area until commissioning takes place.

11 Guarantee

The statutory warranty period applies. If the product is defective, please con- tact the service partner in your country (addresses on the back on the instruc- tion manual).

Our experts will be happy to help you and will discuss the warranty process with you in more detail.

12 Disposal

➤Place the packaging material in the appropriate recycling waste bins

wherever possible. M

If you wish to finally dispose of the device, ask your local recycling centre or specialist dealer for details about how to do this in accordance with the applicable disposal regulations.

Page 35 of the Dometic MCS15 user manual — 13.1 Unit Data
Pagina 35 · clicca per ingrandire
Pagina 35
Dometic MCS15 — 13 Technical data diagram (page 35)
Fig. 36 · 13 Technical data

13 Technical data

13.1 Unit Data

Dometic MCS15 — 13.1 Unit Data diagram (page 35)
Fig. 37 · 13.1 Unit Data
Cooling power5000 Btuh 1500 W 15000 Btuh 4400W
Unit226 x 279 x 452 mm 226 x 279 x 452 mm
Control panel81 x 63 x 23 mm 81 x 63 x 23 mm
Panel cutout64 x 48 mm 64 x 48 mm
Page 36 of the Dometic MCS15 user manual — 13.3 System Inputs
Pagina 36 · clicca per ingrandire
Pagina 36
Dometic MCS15 — 13.2 System Control Specifications diagram (page 36)
Fig. 38 · 13.2 System Control Specifications

13.2 System Control Specifications

Dometic MCS15 — 13.2 System Control Specifications diagram (page 36)
Fig. 39 · 13.2 System Control Specifications
Set Point Operating Range65 °F to 85 °F (18.3 °C to 29.4 °C)

5 °F to 150 °F (–15 °C to 65.6 °C)

Sensor Accuracy± 2 °F at 77 °F (±1.1 °C at 25 °C)

13.3 System Inputs

Dometic MCS15 — 13.3 System Inputs diagram (page 36)
Fig. 40 · 13.3 System Inputs

Versions, technical improvements and delivery options reserved.

Codici sul display

Codici di errore

Il significato dei codici di errore mostrati sul display e come cancellarli.

CodiceSignificatoRisolvi
P-5Temperature Calibration p.20
P-6Failsafe Level p.20
P-7Low AC Voltage Shutdown p.20
P-8De-Icing Cycle p.20
P-9High Water Temperature Limit p.21
P-10Display Brightness Control p.21
P-11Fahrenheit or Celsius Selection p.21
P-12Cycle Pump With Compressor p.21

Fai una domanda su Dometic MCS15

I possessori del prodotto e il nostro team di solito rispondono entro 24 ore, e la tua domanda sarà utile anche ad altri.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Nessuna domanda ancora per il dispositivo Dometic MCS15

Invia la prima domanda: risponderanno altri possessori o il nostro team.

Documento originale

Dometic MCS15 manuale in PDF

264 pagine·6.3 MB·Climatizzatore·PDF
Clicca su qualsiasi pagina in alto per aprirla qui
Pagina 1 / …
100%
Caricamento pagine…