IT
Dometic logo
Manuale d'uso ufficiale

Dometic MCA2440

432 pagine·2.5 MB·Caricabatterie·PDF·EN
Dometic MCA2440
Indice dei contenuti 74 sezioni Table of contents · 1 Explanation of symbols · 2 General safety instructions · 2.1 General safety D · … MostraNascondi
Table of contentsp.11 Explanation of symbolsp.12 General safety instructionsp.22.1 General safety Dp.3DANGER!p.3electrical devices. !p.3WARNING!p.3the device. Ap.3NOTICE!p.32.2 Safety when installing the device Dp.4or dust explosion. !p.4CAUTION!p.42.3 Safety when connecting the device electronically Dp.4somebody close at hand who can help you in emergencies. !p.4the bonnet. Crushed cables can lead to serious injury. !p.42.4 Operating the device safely Dp.5socket must be close to the device and be easily accessible. !p.52.5 Safety precautions when handling batteries !p.6If you sustain any injuries from acids, contact a doctor immediately. !p.6of the engine or battery. Ap.63 Intended usep.74 Scope of deliveryp.85 Accessoriesp.86 Technical descriptionp.96.1 Device versionsp.96.2 Connections and controlsp.106.3 Battery charging functionp.11U/Vp.11I/Ap.11U0 Up.117 Installing the devicep.128 Connecting the devicep.148.1 Connecting to battery and power supplyp.14Observe the following instructions when connecting the battery: !p.148.2 Charge versionsp.15MCA-RC1p.15Charging using the remote control MCA-RC1 (accessory) Ip.168.3 Wiring diagramsp.168.4 Pin assignmentp.171 R_VCCp.172 GNDp.173 TEMPp.174 BAT –p.175 LIN BUS DATA I/Op.176 BAT +p.172 BAT –p.173 NCp.175 GNDp.18+ VCCp.18– GNDp.188.5 Setting the DIP switchesp.19ON OFF 14.4 V / 28.8 Vp.20OFF OFF 14.7 V / 29.4 Vp.20ON OFF 13.5 V / 27.0 Vp.20OFF OFF 13.8 V / 27.6 Vp.20OFF OFF ONp.20ON OFF ONp.20ON ON ONp.20ONp.209 Using the devicep.2110 Maintaining and cleaning the device Ap.2311 Troubleshootingp.2312 Warrantyp.2413 Disposalp.24wherever possible. Mp.2414 Technical datap.25ENV 50204p.25MCA1215 MCA1225 MCA1235 MCA1250 MCA1280p.26MCA2415 MCA2425 MCA2440p.26MCA1215 MCA1225 MCA1235p.27MCA1250 MCA1280p.27MCA1215 – MCA2440p.29Table des matièresp.29FRp.29
Page 1 of the Dometic MCA2440 user manual — Indice dei contenuti
Pagina 1 · Indice
Indice

Indice

Table of contentsp.11 Explanation of symbolsp.12 General safety instructionsp.22.1 General safety Dp.3DANGER!p.3electrical devices. !p.3WARNING!p.3the device. Ap.3NOTICE!p.32.2 Safety when installing the device Dp.4or dust explosion. !p.4CAUTION!p.42.3 Safety when connecting the device electronically Dp.4somebody close at hand who can help you in emergencies. !p.4the bonnet. Crushed cables can lead to serious injury. !p.42.4 Operating the device safely Dp.5socket must be close to the device and be easily accessible. !p.52.5 Safety precautions when handling batteries !p.6If you sustain any injuries from acids, contact a doctor immediately. !p.6of the engine or battery. Ap.63 Intended usep.74 Scope of deliveryp.85 Accessoriesp.86 Technical descriptionp.96.1 Device versionsp.96.2 Connections and controlsp.106.3 Battery charging functionp.11U/Vp.11I/Ap.11U0 Up.117 Installing the devicep.128 Connecting the devicep.148.1 Connecting to battery and power supplyp.14Observe the following instructions when connecting the battery: !p.148.2 Charge versionsp.15MCA-RC1p.15Charging using the remote control MCA-RC1 (accessory) Ip.168.3 Wiring diagramsp.168.4 Pin assignmentp.171 R_VCCp.172 GNDp.173 TEMPp.174 BAT –p.175 LIN BUS DATA I/Op.176 BAT +p.172 BAT –p.173 NCp.175 GNDp.18+ VCCp.18– GNDp.188.5 Setting the DIP switchesp.19ON OFF 14.4 V / 28.8 Vp.20OFF OFF 14.7 V / 29.4 Vp.20ON OFF 13.5 V / 27.0 Vp.20OFF OFF 13.8 V / 27.6 Vp.20OFF OFF ONp.20ON OFF ONp.20ON ON ONp.20ONp.209 Using the devicep.2110 Maintaining and cleaning the device Ap.2311 Troubleshootingp.2312 Warrantyp.2413 Disposalp.24wherever possible. Mp.2414 Technical datap.25ENV 50204p.25MCA1215 MCA1225 MCA1235 MCA1250 MCA1280p.26MCA2415 MCA2425 MCA2440p.26MCA1215 MCA1225 MCA1235p.27MCA1250 MCA1280p.27MCA1215 – MCA2440p.29Table des matièresp.29FRp.29
Page 2 of the Dometic MCA2440 user manual — !
Pagina 2 · clicca per ingrandire
Pagina 2

MCA1215 – MCA2440 General safety instructions

!

➤ ActionThis symbol indicates that action is required on your part. The

required action is described step-by-step.

✓This symbol describes the result of an action.

fig. 1 5, page 3: This refers to an element in an illustration. In this case, item 5 in figure 1 on page 3.

2 General safety instructions

The manufacturer accepts no liability for damage in the following cases:

Faulty assembly or connection

Damage to the product resulting from mechanical influences and excess

Alterations to the product without express permission from the manu-

Use for purposes other than those described in the operating manual

!

voltage · facturer · Injury

Page 3 of the Dometic MCA2440 user manual — NOTICE!
Pagina 3 · clicca per ingrandire
Pagina 3

General safety instructions MCA1215 – MCA2440

2.1 General safety D

DANGER!

In the event of fire, use a fire extinguisher which is suitable for

electrical devices. !

WARNING!

Only use the device as intended.

Disconnect the device from the mains:

– Before cleaning and maintenance – After use – Before changing a fuse

If you disassemble the device:

– Detach all connections – Make sure that no voltage is present at any of the inputs and outputs

The device may not be used if the device itself or the connection

cable are visibly damaged.

If this power cable for this device is damaged, it must be

replaced by the manufacturer, customer service or a similarly qualified person in order to prevent safety hazards.

This device may only be repaired by qualified personnel.

Inadequate repairs may cause serious hazards.

People (including children) whose physical, sensory or mental

capacities prevent them from using this device safely may not be allowed to operate it without the supervision of a responsible adult.

Electrical devices are not toys.

Always keep and use the appliance out of the reach of children.

Children must be supervised to ensure that they do not play with

the device. A

NOTICE!

Before start-up, check that the voltage specification on the type

plate is the same as that of the power supply.

Ensure that other objects cannot cause a short circuit at the

contacts of the device.

Never pull the plug out of the socket by the connection cable.

Store the device in a dry and cool place.

Page 4 of the Dometic MCA2440 user manual — CAUTION!
Pagina 4 · clicca per ingrandire
Pagina 4

MCA1215 – MCA2440 General safety instructions

2.2 Safety when installing the device D

DANGER!

Never mount the device anywhere where there is a risk of gas

or dust explosion. !

CAUTION!

Ensure that the device is standing firmly.

The device must be set up and fastened in such a way that it cannot tip over or fall down. A

NOTICE!

Do not expose the device to a heat source (such as direct sun-

light or heating). Avoid additional heating of the device in this way.

Set up the device in a dry location where it is protected against

splashing water.

2.3 Safety when connecting the device electronically D

For installation on boats:

If electrical devices are incorrectly installed on boats, corrosion damage might occur. Have the device installed by a specialist (marine) electrician.

If you are working on electrical systems, ensure that there is

somebody close at hand who can help you in emergencies. !

WARNING!

Always use sockets which are grounded and secured by

residual current circuit breakers.

Make sure that the lead has a sufficient cross-section.

Lay the cables so that they cannot be damaged by the doors or

the bonnet. Crushed cables can lead to serious injury. !

CAUTION!

Lay the cables so that they cannot be tripped over or damaged.

Page 5 of the Dometic MCA2440 user manual — CAUTION!
Pagina 5 · clicca per ingrandire
Pagina 5

General safety instructions MCA1215 – MCA2440

A

NOTICE!

Use ductwork or cable ducts if it is necessary to lay cables

through metal panels or other panels with sharp edges.

Do not lay the 230 V mains cable and the 12 V DC cable in the

same duct.

Do not lay the cable so that it is loose or heavily kinked.

Fasten the cables securely.

Do not pull on the cables.

2.4 Operating the device safely D

Do not touch exposed cables with your bare hands. This applies

especially when operating the device from the AC mains.

To be able to disconnect the device quickly from the mains, the

socket must be close to the device and be easily accessible. !

WARNING!

Only use the device in closed, well-ventilated rooms.

Do not operate the device in systems with lead acid batteries.

These batteries give off explosive hydrogen gas that can be ignited by sparks on electrical connections. !

CAUTION!

Do not operate the device

– In salty, wet or damp environments – In the vicinity of corrosive fumes – In the vicinity of combustible materials – In areas where there is a danger of explosions.

Before starting the device, ensure that the power supply line

and the plug are dry.

Always disconnect the power supply when working on the

device.

Please observe that parts of the device may still conduct voltage

even if the fuse has blown.

Do not disconnect any cables when the device is still in use.

Page 6 of the Dometic MCA2440 user manual — NOTICE!
Pagina 6 · clicca per ingrandire
Pagina 6

MCA1215 – MCA2440 General safety instructions

A

NOTICE!

Make sure the air inlets and outlets of the device are not

covered.

Ensure good ventilation.

2.5 Safety precautions when handling batteries !

WARNING!

Batteries contain aggressive and caustic acids. Avoid battery

fluid coming into contact with your body. If your skin does come into contact with battery fluid, wash the part of your body in question thoroughly with water.

If you sustain any injuries from acids, contact a doctor immediately. !

CAUTION!

When working on the batteries, do not wear any metal objects

such as watches or rings.

Lead acid batteries can cause short circuits which can cause serious injuries.

Never attempt to charge a frozen or defective battery.

Place the battery in a frost-free area and wait until the battery has acclimatised to the ambient temperature. Then start the charging process.

Wear goggles and protective clothing when you work on

batteries. Do not touch your eyes when you are working on the battery.

Do not smoke and ensure that no sparks can arise in the vicinity

of the engine or battery. A

NOTICE!

Only use rechargeable batteries.

Prevent any metal parts from falling on the battery. This can

cause sparks or short-circuit the battery and other electrical parts.

Make sure the polarity is correct when connecting the battery.

Page 7 of the Dometic MCA2440 user manual — 3 Intended use
Pagina 7 · clicca per ingrandire
Pagina 7

Intended use MCA1215 – MCA2440

Follow the instructions of the battery manufacturer and those of

the manufacturer of the system or vehicle in which the battery is used.

If you need to remove the battery, first disconnect the earth

connection. Disconnect all connections and all consumers from the battery before removing it.

3 Intended use

The WAECO PerfectCharge MCA360 battery charger can charge or supply a retention voltage to batteries which are used to generate power in vehicles or on boats.

The MCA charger can be used to continuously charge supply or starter bat- teries. This allows the batteries to be charged and to maintain a high charge level:

12 V batteriesMCA1215, MCA1225, MCA1235, MCA1250, MCA1280
24 V batteriesMCA2415, MCA2425, MCA2440

The MCA battery charger are designed to charge the following battery types:

Absorbed glass mat (AGM) batteries

Never use the devices to charge other battery types (such as NiCd or NiMH). !

Do not charge batteries with a cell short circuit. The oxyhydro-

gen they produce can cause explosions.

Do not charge lead batteries in unventilated rooms. The oxy-

hydrogen they produce can cause explosions.

Do not charge nickel cadmium and non-rechargeable batteries

with the charger. The cases of these batteries can burst explo- sively.

Lead starter batteries · Lead gel batteries

Page 8 of the Dometic MCA2440 user manual — 5 Accessories
Pagina 8 · clicca per ingrandire
Pagina 8

MCA1215 – MCA2440 Scope of delivery

4 Scope of delivery

2 230 V power cable

3 Installation and operating manual

Check before starting up the device that all parts are available belonging to the scope of delivery.

5 Accessories

Available as accessory (not included in scope of delivery):

Description Item no.

Remote Control MCA-RC1 9102500037

Temperature sensor MCA-TS1 9102500036

Battery sensor MCA-HS1 (IBS) 9102500038

Perfect Control Display MPC01 910250041

Quantity Description · 1 Battery charger

Page 9 of the Dometic MCA2440 user manual — 6.1 Device versions
Pagina 9 · clicca per ingrandire
Pagina 9

Technical description MCA1215 – MCA2440

6 Technical description

The low weight and compact construction of the battery charger allow for easy installation in mobile homes, commercial vehicles or motor and sailing yachts. It charges batteries that are used on board vehicles or boats to generate power or supplies them with a retention voltage so that they do not discharge.

A control lamp on the device enables constant monitoring in the battery charger.

The device has the following protective systems:

with sensor (accessory)Battery overheating

The device can also be integrated into a LIN bus using two connections.

The cooling system uses fans whose speed depends on the charging power and can be switched off using an external switch.

6.1 Device versions

The PerfectCharge MCA battery chargers are available in different versions.

Your MAC battery charger can be used to charge batteries up to a specified battery capacity (see “Technical data” on page 60):

MCA1215suitable for charging one supply battery and one starter
MCA1225, MCA1235suitable for charging up to two supply batteries and
MCA1250, MCA1280suitable for charging up to three supply batteries
MCA2415suitable for charging up to two supply batteries
MCA2425, MCA2440suitable for charging up to three supply batteries

For the identification of your device, see the item number on the type plate.

Show 4 more labels / short text on this page
Short circuit · Overheating protection · battery · one starter battery
Page 10 of the Dometic MCA2440 user manual — 6.2 Connections and controls
Pagina 10 · clicca per ingrandire
Pagina 10

MCA1215 – MCA2440 Technical description

6.2 Connections and controls

No. in fig. 1, page 3 Explanation/function

2 LIN2 bus connection

3 TENMP/LIN1 bus connection

4 CN2 socket for Alarm and Fan

7 Battery terminals (+)

8 Battery terminals (–)

9 Starter battery connection (MCA 1215, MCA 1225, MCA 1235 only)

No. in fig. 2, page 4 Explanation/function

Show 5 more labels / short text on this page
1 Mains connection · 5 Status LED · 6 DIP switch · 1 Fan · 2 On/Off switch
Page 11 of the Dometic MCA2440 user manual — U
Pagina 11 · clicca per ingrandire
Pagina 11

Technical description MCA1215 – MCA2440

6.3 Battery charging function

The charging characteristics are referred to as modified IU0U characteristics.

U/V

I/A

2 3 4 6 5

U

U0 U

1. I phase (bulk)

At the beginning of the charging process, the flat battery is charged with a constant current (100% charge current) until the battery voltage reaches the charging voltage. The charging current decreases when the battery has reached this charging level.

2, 3, 4U0 phase (absorption)

Now the three-stage absorption charging process (U0 phase) begins, where the duration depends on the battery. The voltage remains constant (U0). In the first 2 minutes, the charging of the battery is determined. Then the main charging phase begins when the battery is fully charged.

Once the battery is completely charged, or the charging current is below 6 % of the rated charging current for 15 minutes, the U0 phase has finished.

100 % · 6 % · t

Page 12 of the Dometic MCA2440 user manual — 7 Installing the device
Pagina 12 · clicca per ingrandire
Pagina 12

MCA1215 – MCA2440 Installing the device

5. U phase (float)

After the U0 phase, the battery charger switches to conservation charging function (U phase).

If DC loads are connected, they are powered by the device. Only if the power required exceeds the capacity of the device is this surplus power provided by the battery. The battery is then discharged until the device re-enters the I phase and charges the battery.

6. 12-day conditioning

Every 12 days, the battery charger switches back to phase 1 for 85 min in order to revive the battery. This prevents any fatigue symptoms such as sulphation.

7 Installing the device

When selecting the installation location, observe the following instructions:

The device can be installed horizontally or vertically.

Do not install the device

– In wet or damp environments – In dusty environments – In the vicinity of combustible materials – In areas where there is a danger of explosions.

The place of installation must be well ventilated. A ventilation system must

be available for installations in small, enclosed spaces. The clearance around the device must be at least 25 cm.

The air inlet on the underside and the air outlet on the back of the device

must remain clear.

For ambient temperatures higher than 40 °C (such as in engine or heating

compartments, or direct sunlight), the heat from the device under load can lead to reduced output.

The device must be installed on a level and sufficiently sturdy surface.

Do not install the device in the same area as the batteries.

Do not install the device above batteries, because they can emit corrosive

sulphur fumes that will damage the device.

Page 13 of the Dometic MCA2440 user manual — A
Pagina 13 · clicca per ingrandire
Pagina 13

Installing the device MCA1215 – MCA2440

A

For installation and mounting you will need the following tools:

To secure the device in place you will need:

Machine bolts (M4) with washers and self-locking nuts or

self-tapping screws or wood screws.

Fasten the device as follows:

➤Hold the device against the installation location.

➤Mark the fastening points.

➤Fasten the device with one screw through each hole in the holders.

Show 4 more labels / short text on this page
Pen for marking · Drill bit set · Drill · Screwdriver
Page 14 of the Dometic MCA2440 user manual — 8.1 Connecting to battery and power supply
Pagina 14 · clicca per ingrandire
Pagina 14

MCA1215 – MCA2440 Connecting the device

8 Connecting the device

8.1 Connecting to battery and power supply

Observe the following instructions when connecting the battery: !

CAUTION!

Avoid coming into contact with the battery fluid.

Batteries with a cell short circuit may not be charged, as explo-

sive gases may form due to overheating of the battery.

Make sure the battery terminals are clean when connecting them.

Make sure the plug connector is fitted securely.

Select a connection cable with a sufficient cross-section (see “Technical

data” on page 60).

Lay the cables in accordance with VDE°100 (Germany).

Connect the negative cable directly to the negative terminal of the battery,

and not to the chassis of a vehicle or boat.

Use the following cable colours:

– Redpositive connection – Black: negative connection

Do not reverse the polarity. Reversing the polarity can damage to the de-

vice.

➤Lay the positive cable from the battery charger to the positive terminal of

the battery and connect it.

➤Lay the negative cable from the battery charger to the negative terminal

of the battery and connect it.

Connecting the 230 V power supply

➤Plug the 230 V connection cable included in the delivery into the MCA

battery charger‘s “AC INPUT” socket.

➤Connect the device with the he 230 V connection cable to a 230 V socket

which is protected by a residual current circuit breaker.

Connecting the battery

Page 15 of the Dometic MCA2440 user manual — MCA-RC1
Pagina 15 · clicca per ingrandire
Pagina 15

Connecting the device MCA1215 – MCA2440

8.2 Charge versions

fig. 3, page 5 fig. 4, page 5

Battery sensor MCA-HS1 (IBS)

MCA-RC1

MCA-TS1 or Battery sensor MCA-HS1 (IBS)

–

✓ – ✓ –

✓ ✓ – ✓

– without; ✓ with

➤Connect the battery to the “DC OUTPUT” socket of the MCA battery

charger.

Make sure the polarity of the connections is correct.

Charging the starter battery (MCA1215, 1225, 1235 only)

➤Connect the starter battery to the “ESB” socket of the MCA battery

charger.

Make sure the polarity of the connections is correct.

Charging using the temperature sensor MCA-TS1 (accessory)

➤Connect the temperature sensor to the TEMP/LIN connection.

✓The charging voltage is adjusted according to the temperature measured.

Charging using the IBS battery sensor MCA-HS1 (accessory)

➤Connect the battery sensor to the TEMP/LIN connection.

✓The battery sensor transmits the battery temperature and the battery

voltage to the charger via the LIN communication port. The charging voltage is regulated according to the temperature. Any potential loss of voltage in the connecting cables is also compensated.

Charging using the Perfect Control display MPC01 (accessory)

You can find detailed information in the operating manual for MPC01.

Show 6 more labels / short text on this page
Perfect Control dis- · Remote control · Temperature sensor · play MPC01 · ✓ ✓ · Charging the battery
Page 16 of the Dometic MCA2440 user manual — 8.3 Wiring diagrams
Pagina 16 · clicca per ingrandire
Pagina 16

MCA1215 – MCA2440 Connecting the device

Charging using the remote control MCA-RC1 (accessory) I

➤Insert one end of the RJ-11 cable into the socket (fig. 0 3, page 7) of the

MCA-RC1.

➤Insert the other end of the RJ-11 cable into the TEMP/LIN1 socket on the

MCA battery charger.

➤Fit a suitable fuse to the control cable (12 V/0.5 A).

➤Set the DIP switches 1 to 3 on the MCA battery charger to “ON” (“Setting

the DIP switches” on page 54).

8.3 Wiring diagrams

Example of a wiring diagram, 12 V: see fig. 5, page 6.

No. in fig. 5, page 6 Explanation/function

3 Perfect Control display MPC01

4 12 V battery sensor IBS

5 12 V battery

Show 4 more labels / short text on this page
1 MCA charger · 2 Consumer · 6 Fuse · 7 Starter battery
Page 17 of the Dometic MCA2440 user manual — 1 R_VCC
Pagina 17 · clicca per ingrandire
Pagina 17

Connecting the device MCA1215 – MCA2440

Example of a wiring diagram, 24 V: see fig. 6, page 6.

No. in fig. 6, page 6 Explanation/function

3 Perfect Control display MPC01

4 24 V battery sensor IBS

5 12 V battery

8.4 Pin assignment

The pins for the TEMP/LIN1 bus socket are assigned as follows:

Pin in fig. 7, page 6 Allocation

1 R_VCC

2 GND

3 TEMP

4 BAT –

5 LIN BUS DATA I/O

6 BAT +

The pins for the LIN2 bus socket are assigned as follows:

Pin in fig. 7, page 6 Allocation

1 R_VCC

2 BAT –

3 NC

4 BAT –

5 LIN BUS DATA I/O

6 BAT +

1 MCA charger · 2 Consumer · 6 Fuse

Page 18 of the Dometic MCA2440 user manual — + VCC
Pagina 18 · clicca per ingrandire
Pagina 18

MCA1215 – MCA2440 Connecting the device

The pins for the CN2 socket (alarm signal and fan control) are assigned as follows:

Pin in fig. 8, page 6 Allocation

1 NC (Normally Closed)normally closed contact
2 NO (Normally Open)normally open contact
3 COM (Common)common contact

4 Sleep mode control

5 GND

4. 5 bridged Sleep mode on
4. 5 open Sleep mode off

The pins for the ESB socket (starter battery connection) are assigned as follows:

Pin in fig. 9, page 6 Allocation

+ VCC

– GND

Page 19 of the Dometic MCA2440 user manual — 8.5 Setting the DIP switches
Pagina 19 · clicca per ingrandire
Pagina 19

Connecting the device MCA1215 – MCA2440

8.5 Setting the DIP switches

You can adjust the device using the DIP switch.

S1 is used to set the voltage at which the device switches over from the I phase (bulk) to the U0 phase (absorption) (also see “Battery charging func- tion” on page 46). S3 must be set to “OFF”.

S2 is used to set the retention voltage. S3 must be set to “OFF”.

When a battery sensor is connected, the output voltages is adapted to the temperature for these two functions:

MCA 12xx–20 mV/°C
MCA 24xx–40 mV/°C

S3 activates the power mode when either S1 or S2, or both, are set to “Off”. In power mode, the short circuit, overvoltage and overheating protection are controlled by the internal sensor.

When S1, S2 and S3 are set to “Off”, then the remote control is activated. The type of battery and the charging voltage are set using the remote control in this mode.

S4 regulates the fan function. When S4 is set to “On”, then the fan is switched to sleep mode (noise-reduced mode). When S4 is set to “Off”, then the fan is not regulated.

Page 20 of the Dometic MCA2440 user manual — ON
Pagina 20 · clicca per ingrandire
Pagina 20

MCA1215 – MCA2440 Connecting the device

➤Use the DIP switches (fig. a page 7) to set the required functions and

values– To set the switchover voltage:

Switch 1 Switch 3 Switchover voltage

ON OFF 14.4 V / 28.8 V

OFF OFF 14.7 V / 29.4 V

– To set the retention voltage:

Switch 2 Switch 3 Retention voltage

ON OFF 13.5 V / 27.0 V

OFF OFF 13.8 V / 27.6 V

– To set the power mode:

Switch 1 Switch 2 Switch 3 Switchover volt-

OFF OFF ON

13.2 V / 26.4 V 13.2 V / 26.4 V OFF ON ON

ON OFF ON

– To activate the remote control:

Switch 1 Switch 2 Switch 3

ON ON ON

– To activate sleep mode:

ON

age Retention voltage · Switch 4

Page 21 of the Dometic MCA2440 user manual — 9 Using the device
Pagina 21 · clicca per ingrandire
Pagina 21

Using the device MCA1215 – MCA2440

9 Using the device

➤Set the On/off switch to “On”.

To switch off the device set the On/off switch to “On”.

✓Depending on the charging condition of the battery, the battery charger

starts charging or supplies a retention voltage.

✓The “Status” LED (fig. 1 5, page 3) displays the operating status (see

following table and “Battery charging function” on page 46).

Orange, quickly flashing Phase 1

Orange, slowly flashing Phase 2

Orange, constantly lit Phase 3

Green, constantly lit Phase 4

Green, slowly flashing Phase 5

Red, constantly lit Short circuit or defective fuse

Red, quickly flashing Battery or battery charger is overheat- ing

Red, slowly flashing Battery undervoltage or overload

Red, double flash Fan fault

Red, slow double flash Fault at the starter battery connection

Display Meaning

Page 22 of the Dometic MCA2440 user manual — 9 Using the device
Pagina 22 · clicca per ingrandire
Pagina 22

MCA1215 – MCA2440 Using the device

When you have connected the remote control MCA-RC1 (accessory)

➤Activate or deactivate sleep mode (noise reduced mode) using the “Sleep

Mode” button (fig. 0 2, page 7).

The fan is not regulated in sleep mode.

✓The LED (fig. 0 1, page 7) on the MCA-RC1 indicates the operating status

(see following table).

Phase 1 to 5

Phase 1 to 4

Green, constantly lit Phase 5

Fault Red, constantly lit Short circuit or defective fuse

Battery or battery charger is over- heating

Red, slowly flashing Battery undervoltage or overload

Red, double flash Fan fault

Red, slow double flash

Fault at the starter battery connec- tion

Show 6 more labels / short text on this page
Mode Display Meaning · Sleep mode activated · Orange, constantly lit · Sleep mode deactivated · Green, slowly flash- ing · Red, quickly flash- ing
Page 23 of the Dometic MCA2440 user manual — 11 Troubleshooting
Pagina 23 · clicca per ingrandire
Pagina 23

Maintaining and cleaning the device MCA1215 – MCA2440

10 Maintaining and cleaning the device A

➤Disconnect the device from the 230 V power supply.

➤Disconnect the device from the battery.

➤Prevent the device from being switched on.

➤Occasionally clean the device with a damp cloth.

➤Regularly clean the vents.

➤Check the electrical wiring at least once a year.

Repair any defects such as loose connections or burnt cables.

11 Troubleshooting

The “Status” LED (fig. 1 5, page 3) displays the fault:

LED display Cause Remedy

Red, slowly flashing Battery undervoltage or bat- tery overload

Check the battery.

Switch the battery charger off and on again.

Defective battery Replace the battery.

Red, slowly flashing Overheating Improve the ventilation of the battery charger or battery.

Make sure that no ventilation open- ings are covered.

If necessary, reduce the ambient temperature.

Red, permanently lit Short circuit or reversed polarity

Connect the battery charger with the correct polarity.

Rectify the short circuit.

Check if the fuse has triggered and replace it if necessary.

Red, double flash Fan fault Check the fan for dirt or damage.

Red, slow double flash

Fault at the starter battery connection

Check the starter battery connection for a short circuit.

Page 24 of the Dometic MCA2440 user manual — wherever possible. M
Pagina 24 · clicca per ingrandire
Pagina 24

MCA1215 – MCA2440 Warranty

12 Warranty

The statutory warranty period applies. If the product is defective, please contact the manufacturer's branch in your country (see the back of the instruction manual for the addresses) or your retailer.

For repair and guarantee processing, please include the following docu- ments when you send in the device:

A copy of the receipt with purchasing date

A reason for the claim or description of the fault

13 Disposal

➤Place the packaging material in the appropriate recycling waste bins

wherever possible. M

If you wish to finally dispose of the product, ask your local recycling centre or specialist dealer for details about how to do this in accordance with the applicable disposal regulations.

Page 25 of the Dometic MCA2440 user manual — ENV 50204
Pagina 25 · clicca per ingrandire
Pagina 25

Technical data MCA1215 – MCA2440

14 Technical data

Battery types Lead-acid, gel, AGM, Li-Ion

Maximum ambient temperature –20 °C – +50 °C

Storage temperature -40 °C – +85 °C

Air humidity 20 – 90 %

Temperature coefficient ± 0.03 %/°C (0 – 50 °C)

Temperature compensation (MCA 12xx) Temperature compensation (MCA 24xx)

–20 mV/°C (battery sensor)

-40 mV/°C (battery sensor)

Vibration 10 – 500 Hz

2 g for 10 min/cycle within 60 minutes for X, Y and Z axis

Voltage insulation I/P – O/P4 kV w
I/P – FG1.7 kV w
O/P – FG0.7 kV w
Insulation resistance I/P – O/P100 M Ω /500 V g

Alarm signal via relay contact

Sleep mode (noise-reduced mode) via remote control (accessory) or DIP switch

Remote control (accessory) On/off switch, three-colour LED, sleep mode

In compliance with the EMC directive 2004/108/EC including 2009/19/EC and the Low-voltage Directive 2006/95/EC

ENV 50204

Show 7 more labels / short text on this page
General technical data · MCA12xx, MCA24xx · Heat dissipation Fan · Charge mode 5-level · Communication via LIN-BUS · option · Testing/certification
Page 26 of the Dometic MCA2440 user manual — MCA2415 MCA2425 MCA2440
Pagina 26 · clicca per ingrandire
Pagina 26

MCA1215 – MCA2440 Technical data

Output side short circuit Current is reduced to 25% of the maximum

Battery charger over temperature 100 °C ± 5 °C (measured internally)

Battery over temperature 52 °C ± 5°C (with battery sensor)

MCA1215 MCA1225 MCA1235 MCA1250 MCA1280

Rated input voltage 90 – 260 Vw

Output factor correction > 97% (full load)

Input frequency 50 Hz – 60 Hz

Efficiency at 230 Vw 87%

Leakage current < 1 mA at 240 Vw

Input current at 100 Vw 2.5 A 4.1 A 6.2 A 8.24 A 13.3 A

Input current at 240 Vw 1.07 A 1.8 A 2.8 A 3.6 A 5.4 A

MCA2415 MCA2425 MCA2440

Rated input voltage 90 – 260 Vw

Output factor correction > 97% (full load)

Input frequency 50 Hz – 60 Hz

Efficiency at 230 Vw 90 %

Leakage current < 1 mA at 240 Vw

Input current at 100 Vw 4.2 A 8.3 A 13.3 A

Input current at 240 Vw 1.7 A 3.6 A 5.4 A

Show 5 more labels / short text on this page
Protective devices · MCA12xx, MCA24xx · current · Overvoltage 16 V · Input data
Page 27 of the Dometic MCA2440 user manual — MCA2415 MCA2425 MCA2440
Pagina 27 · clicca per ingrandire
Pagina 27

Technical data MCA1215 – MCA2440

MCA1215 MCA1225 MCA1235 MCA1250 MCA1280

Charging voltage 14.4 V / 14.7 V

Retention voltage 13.8 V

Rated charging current 15 A 25 A 35 A 50 A 80 A

Charging current 0 – 15 A 0 – 25 A 0 – 35 A 0 – 50 A 0 – 80 A

Outputs 1 2 2 3 3

ESB outputs (Starter battery)

1 1 1 – –

ESB charging voltage 13.8 V 13.8 V 13.8 V – –

ESB charging current 2 A 2 A 2 A – –

MCA2415 MCA2425 MCA2440

Charging voltage 28.8 V / 29.4 V

Retention voltage 27.6 V

Rated charging current 12.5 A 25 A 40 A

Charging current 0 – 12.5 A 0 – 25 A 0 – 40 A

Outputs 2 3 3

Item number, dimensions and weight:

MCA1215 MCA1225 MCA1235

Item no. 9102500027 9102500028 9102500029

Dimensions L x W x H (mm) 238x179x63 238x179x63 274x179x63

Weight 1.6 kg 1.7 kg 1.9 kg

MCA1250 MCA1280

Item no. 9102500030 9102500031

Dimensions L x W x H (mm) 283x208.5x75 303x208.5x75

Weight 3.1 kg 3.9 kg

MCA2415 MCA2425 MCA2440

Item no. 9102500032 9102500033 9102500034

Dimensions L x W x H (mm) 238x179x63 283x208.5x75 303x208.5x75

Weight 1.6 kg 2.9 kg 3.9 kg

Output data

Page 28 of the Dometic MCA2440 user manual — MCA-RC1
Pagina 28 · clicca per ingrandire
Pagina 28

MCA1215 – MCA2440 Technical data

Technical data MCA-RC1 (accessory)

MCA-RC1

Item no. 9102500037

Rated input voltage 10.5 – 15 Vg

Standby current consumption < 40 mA

Maximum ambient temperature -10 °C – +45 °C

Storage temperature -30 °C – +70 °C

Fai una domanda su Dometic MCA2440

I possessori del prodotto e il nostro team di solito rispondono entro 24 ore, e la tua domanda sarà utile anche ad altri.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Nessuna domanda ancora per il dispositivo Dometic MCA2440

Invia la prima domanda: risponderanno altri possessori o il nostro team.

Documento originale

Dometic MCA2440 manuale in PDF

432 pagine·2.5 MB·Caricabatterie·PDF
Clicca su qualsiasi pagina in alto per aprirla qui
Pagina 1 / …
100%
Caricamento pagine…