Instruction Manual Thank you for choosing our product. We hope you enjoy using the appli- ance.
and, if possible, the box with the internal packing. If you give this device to other people, please also pass on the operating instructions.
Symbols in these Instructions for Use Important information for your safety is specially marked. It is essential to comply with these instructions in order to avoid accidents and prevent damage to the machine:
General Notes Read the operating instructions carefully before putting the appliance into operation and keep the instructions including the warranty, the receipt

Overview of the Components 1 Air inlet on the side of the appliance (Filter) 2 Control panel 3 Mains cable 4 Air outlet (fi ns) 5 Exhaust pipe connector 6 Rear side air inlet (Filter) 7 Exhaust pipe adapter 8 Flexible exhaust pipe 9 Water outlet 10 POWER button 11 TEMP + button 12 TEMP − button 13 IR receiver for remote control 14 Display 15 MODE button 16 SPEED button 17 TIMER button 18 LED WATER FULL
Assembly of exhaust pipe
1. Turn the adapter (7) to one end of the exhaust pipe. 2. Connect the exhaust pipe to the unit using the exhaust pipe connector. Set the adapter fi rst on the left side. Press the adapter on the right side down into the linkage. 3. Extend the pipe to the desired length. 4. Stick the open end of the pipe into a window. 5. Close the window as far as possible. Also lower any external roller blinds, if present, to the end of the pipe.
Remote control 1. Open the battery compartment cover on the back of the remote control. 2. Insert 2 batteries of type R03 “AAA” 1.5 V, observing the correct polari- ty (see markings on the bottom of the compartment)! 3. Close the battery compartment cover.
Supplied parts 1 Air conditioning unit 1 Remote control 2 Batteries 1 Flexible exhaust pipe 1 Exhaust pipe adapter (Connection on the appliance) 1 Window kit, 3-piece 1 Water hose, Ø 10 mm 2 Rubber caps (spares) 2 Plugs (spares)
Mains connection 1. Make sure the mains voltage you want to use corresponds to the volt- age of the unit. Please check the rating label for detailed specifi cations. 2. Connect the unit to a properly installed grounded socket. A signal will sound indicating that the unit is ready for use. The display will show the current room temperature with low illumination.
Unpacking the appliance 1. Remove the appliance from its packaging. 2. Remove all the packaging material such as plastic bags, fi ller material, cable ties and cardboard packaging. 3. Check that all parts are supplied in the package.
Handling batteries

Timer (Automatic timer) Use the timer function to set the power-on and power-off times of the device. Select a time between 1 and 24 hours.
Using the timer function for automatic power-on 1. Press the POWER button to turn on the unit. 2. Select the operating mode, temperature and fan speed for the unit to operate in or at when powered on at the pre-set time. 3. Press the POWER button to turn off the unit. 4. Press the TIMER button. The display shows the previously set opera- tion mode and the symbol
Indications on the Display
. The number of hours fl ashes. 5. You can set the desired number of hours with the buttons TEMP + and TEMP −. The setting changes rapidly when you hold down the respective button. Confi rm your setting with the TIMER button while the display is fl ashing. Otherwise you will exit the setting mode. In this case, the setting will not be applied.
Indication of the desired room temperature or the hours in case of TIMER operation
Using the timer function for automatic power-off 1. Press the POWER button to turn on the unit. 2. Press the TIMER button during operation. The display also shows the symbol
Indication with TIMER operation
The unlit segments do not function on this appliance.
Operating modes Use the MODE button to select one of the following operating modes:
Emptying the water tank The unit integrates a water tank for collecting condensation. When the water tank is full, the pilot lamp “WATER FULL” lights up. The display shows “E2”. The compressor switches off in each operation mode. The fan keeps running independent of this.
Operating mode “AUTO” (Automatic) The appliance decides the must suitable operation mode as shown in the following table:
For continued operation with the compressor, you must empty the water tank. For this, you need a fl oor cloth, a fl at bowl with a capacity for approx. 1,5 litres of water and the water hose supplied with the appliance.
Room temperature Operating mode Temperature setting
< 23 °C Fan – – –
≥ 23 °C – < 26 °C Dehumidifying 23 °C
1. Disconnect the mains plug from the wall socket. 2. Place the fl oor towel and the fl at bowl underneath the water outlet. If possible, set the bowl on a lower level than the appliance. 3. Remove the rubber cap and the plug. Keep the parts for later use. 4. Connect the water hose to the water outlet of the appliance. Place the end of the hose in the bowl. 5. After the water has been discharged, remove the water hose. Close the water outlet on the appliance again with the plug and the rubber cap to ensure the condensation water cooling circulation.
≥ 26 °C Cooling 25 °C
You can set the speed of the fan. The temperature setting cannot be changed.
Operating mode “Cooling” In this operation mode, you can adjust the fan speed and the temperature as desired. If you want to use the appliance with the fan only but without compressor, set a temperature higher than the actual room temperature.
Terminating operation 1. Press the POWER button to turn off the unit. 2. Disconnect the mains plug from the wall socket.
Setting the temperature Use the TEMP + or TEMP − buttons in “Cooling”
mode to set the temperature. Select a temperature between 16 °C and 31 °C.
Setting the fan In “Cooling”
and AUTO modes you can set the fan speed with 3 differ- ent settings. Press the SPEED button accordingly.
Fan speed · Cooling mode · Dehumidifying mode

Problem Possible cause Solution
Unit too noisy during operation.
The unit is not in an upright position.
Place the unit on a fl at surface. Avoid vibra- tions.
Display indication: E2 The red LED “WATER FULL” is lit.
The water tank is full. Turn the appliance off. Pull the power plug. Empty the water tank. You may then restart the unit again.
Filter When using the unit daily, clean the fi lter every 2 weeks. If dust in the fi lters blocks the air circulation, effi cient operation of the unit can no longer be guaranteed. 1. Remove the exhaust air hose with the adapter. 2. Pull out the two fi lters on the side of the appliance. 3. Remove the two fi lters on the rear of the appliance. Use a tool (for example, a screwdriver). Attach the tool to the locking tabs and lever the cover off. 4. Vacuum the fi lters for cleaning. 5. Clean the fi lters under running water. If necessary, use a mild deter- gent. 6. Let the fi lters air-dry in a shady place. 7. Reinstall the fi lters when completely dry.
Defective electronics. Contact our customer service or your dealer.
Technical Data Model: CL 3637 Net weight: approx. 25 kg Power supply: 220 - 240 V~, 50 Hz Power consumption: 780 W Protection class: I Energy effi ciency class: A Cooling capacity: 7000 BTU (2.05 kW) Refrigerant: R 410 A
The right to make technical and design modifi cations in the course of continuous product development remains reserved.
This device has been tested according to all relevant current CE guide- lines, such as electromagnetic compatibility and low voltage directives, and has been constructed in accordance with the latest safety regulations.
Seasonal cleaning and storage When not using the unit for a long period of time, proceed as follows:
with a temper- ature above room temperature, so that the appliance runs without the compressor and only the fan is used. This dries the appliance from the inside. 3. Press the POWER button to turn off the unit. Disconnect the mains plug from the wall socket. 4. Disconnect the fl exible exhaust pipe from the unit. 5. an the fi lters and the unit as described above. 6. Cover the unit with foil. 7. Always store the appliance out of the reach of children in a dry, well ventilated place.
As a consumer you are obliged by law to return old batteries/
accumulators.
Remove the batteries from the remote control before disposing of the device.
Return the batteries to a collection facility for the collection of old batteries or hazardous waste. Contact your local authority for more information.
Meaning of the “Dustbin” Symbol
Protect our environment: do not dispose of electrical equip- ment in the domestic waste.
Please return any electrical equipment that you will no longer use to the collection points provided for their disposal.
Problem Possible cause Solution
Unit does not function.
No power supply. Check the power con- nection.
This helps avoid the potential effects of incorrect disposal on the environ- ment and human health.
The display shows the symbol
Press the POWER but- ton to turn on the unit.
This will contribute to the recycling and other forms of utilisation of electri- cal and electronic equipment.
. Timer function is activated.
Information concerning where the equipment can be disposed of can be obtained from your local authority.
Unit does not cool suffi ciently.
The unit is exposed to direct sunshine.
Choose another location or shade the windows.
Windows or doors are open.
Close any windows or doors.
There are too many people or other heating sources in the room.
Remove portable heat- ers or switch them off.
The fi lters are dirty. Clean the fi lters.
The air inlet or air outlet is blocked.
Remove the blockage. Keep the ventilation openings free from obstructions.
Problemi comuni, cause probabili e soluzioni.
| Problema | Possibile causa | Soluzione | |
|---|---|---|---|
| Unit too noisy during operation. | The unit is not in an upright position. | Place the unit on a fl at surface. Avoid vibra- tions. | p.4 |
| Display indication: E2 The red LED “WATER FULL” is lit. | The water tank is full. | Turn the appliance off. Pull the power plug. Empty the water tank. You may then restart the unit again. | p.4 |
| Display indication: E0 | Defective electronics. | Contact our customer service or your dealer. | p.4 |
| Unit does not function. | No power supply. | Check the power con- nection. | p.4 |
| Unit does not function. | The display shows the symbol . Timer function is activated. | Press the POWER but- ton to turn on the unit. | p.4 |
| Unit does not cool suffi ciently. | The unit is exposed to direct sunshine. | Choose another location or shade the windows. | p.4 |
| Unit does not cool suffi ciently. | Windows or doors are open. | Close any windows or doors. | p.4 |
| Unit does not cool suffi ciently. | There are too many people or other heating sources in the room. | Remove portable heat- ers or switch them off. | p.4 |
| Unit does not cool suffi ciently. | The fi lters are dirty. | Clean the fi lters. | p.4 |
| Unit does not cool suffi ciently. | The air inlet or air outlet is blocked. | Remove the blockage. Keep the ventilation openings free from obstructions. | p.4 |
I possessori del prodotto e il nostro team di solito rispondono entro 24 ore, e la tua domanda sarà utile anche ad altri.
Invia la prima domanda: risponderanno altri possessori o il nostro team.