IT
Blomberg logo
Manuale d'uso ufficiale

Blomberg DKP 2021

84 pagine·2.7 MB·Cappa aspirante da cucina·PDF·EN
Blomberg DKP 2021
Indice dei contenuti 17 sezioni · · RECOMMENDATIONS AND SUGGESTIONS · INSTALLATION · … MostraNascondi
Page 1 of the Blomberg DKP 2021 user manual —
Pagina 1 · clicca per ingrandire
Pagina 1
Page 1 of the Blomberg DKP 2021 user manual —
Page 2 of the Blomberg DKP 2021 user manual —
Pagina 2 · clicca per ingrandire
Pagina 2
Page 2 of the Blomberg DKP 2021 user manual —
Page 3 of the Blomberg DKP 2021 user manual —
Pagina 3 · clicca per ingrandire
Pagina 3
Page 3 of the Blomberg DKP 2021 user manual —
Page 4 of the Blomberg DKP 2021 user manual — INSTALLATION
Pagina 4 · clicca per ingrandire
Pagina 4

RECOMMENDATIONS AND SUGGESTIONS

The Instructions for Use apply to several versions of this appliance. Ac-

cordingly, you may find descriptions of individual features that do not ap- ply to your specific appliance.

INSTALLATION

  • The manufacturer will not be held liable for any damages resulting from incorrect or improper installation.
  • The minimum safety distance between the cooker top and the extractor hood is 650 mm.
  • Check that the mains voltage corresponds to that indicated on the rating plate fixed to the inside of the hood.
  • For Class I appliances, check that the domestic power supply guarantees adequate earthing. Connect the extractor to the exhaust flue through a pipe of minimum di-
  • ameter 120 mm. The route of the flue must be as short as possible.
  • Do not connect the extractor hood to exhaust ducts carrying combustion fumes (boilers, fireplaces, etc.).
  • If the extractor is used in conjunction with non-electrical appliances (e.g. gas burning appliances), a sufficient degree of aeration must be guaranteed in the room in order to prevent the backflow of exhaust gas. The kitchen must have an opening communicating directly with the open air in order to guarantee the entry of clean air. USE
  • The extractor hood has been designed exclusively for domestic use to eliminate kitchen smells.
  • Never use the hood for purposes other than for which it has ben designed.
  • Never leave high naked flames under the hood when it is in operation.
  • Adjust the flame intensity to direct it onto the bottom of the pan only, making sure that it does not engulf the sides.
  • Deep fat fryers must be continuously monitored during use: overheated oil can burst into flames.
  • Do not flambè under the range hood; risk of fire
  • This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
  • Children should be supervised to ensure that they do not play with the appliance MAINTENANCE
  • Switch off or unplug the appliance from the mains supply before carrying out any maintenance work.
  • Clean and/or replace the Filters after the specified time period.
  • Clean the hood using a damp cloth and a neutral liquid detergent.

Page 5 of the Blomberg DKP 2021 user manual — Dimensions
Pagina 5 · clicca per ingrandire
Pagina 5

CHARACTERISTICS

Dimensions

Blomberg DKP 2021 — Dimensions diagram (page 5)
Fig. 1 · Dimensions

Components Ref. Q.ty Product Components 1 1 Hood Body, complete with: Controls, Light, Blower, Filters 2 1 Telescopic Chimney comprising: 2.1 1 Upper Section 2.2 1 Lower Section 9 1 Reducer Flange ø 150-120 mm 14.1 2 Air Outlet Connection Extension 15 1 Air Outlet Connection Ref. Q.ty Installation Components 7.2.1 2 Upper Chimney Section Fixing Brackets 11 6 Wall Plugs 12a 6 Screws 4,2 x 44,4 12c 6 Screws 2,9 x 9,5 Q.ty Documentation 1 Instruction Manual

Page 6 of the Blomberg DKP 2021 user manual — Wall drilling and bracket fixing
Pagina 6 · clicca per ingrandire
Pagina 6

INSTALLATION

Wall drilling and bracket fixing

Blomberg DKP 2021 — Wall drilling and bracket fixing diagram (page 6)
Fig. 2 · Wall drilling and bracket fixing
  • Wall marking:
  • Draw a vertical line on the supporting wall up to the ceiling, or as high as practical, at the centre of the area in which the hood will be installed.
  • Draw a horizontal line at 650 mm above the hob. Place bracket 7.2.1 on the wall as shown about 1-2 mm from the ceiling or upper limit aligning the centre (notch) with the vertical reference line.
  • Mark the wall at the centres of the holes in the bracket.
  • Place bracket 7.2.1 on the wall as shown at X mm below the first bracket (X = height of the upper chimney section supplied), aligning the centre (notch) with the vertical line.
  • Mark the wall at the centres of the holes in the bracket.
  • Mark a reference point as indicated at 116 mm from the vertical reference line and 320 mm above the horizontal reference line.
  • Repeat this operation on the other side.
  • Drill ø 8 mm holes at all the centre points marked.
  • Insert the wall plugs 11 in the holes.
  • Fix the brackets using the 12a (4,2 x 44,4) screws supplied.
  • Insert the two screws 12a (4,2 x 44,4) supplied in the hood body fixing holes, leaving a gap of 5-6 mm between the wall and the head of the screw.
Page 7 of the Blomberg DKP 2021 user manual — Mounting the hood body
Pagina 7 · clicca per ingrandire
Pagina 7

Mounting the hood body

  • Before attaching the hood body, tighten the two screws Vr located on the hood body mounting points.
  • Hook the hood body onto the screws 12a .
  • Fully tighten the support screws 12a .
  • Adjust the screws Vr to level the hood body.
Blomberg DKP 2021 — Mounting the hood body diagram (page 7)
Fig. 3 · Mounting the hood body
  • Connections DUCTED VERSION AIR EXHAUST SYSTEM When installing the ducted version, connect the hood to the chimney using either a flexible or rigid pipe ø 150 or 120 mm, the choice of which is left to the installer.
  • To install a ø 120 mm air exhaust connection, insert the reducer flange 9 on the hood body outlet.
  • Fix the pipe in position using sufficient pipe clamps (not supplied).
  • Remove possible charcoal filters.
Blomberg DKP 2021 — Mounting the hood body diagram (page 7)
Fig. 4 · Mounting the hood body
  • RECIRCULATION VERSION AIR OUTLET
  • Push fit connection 15 onto the hood body outlet .
  • Insert the connection extension pieces laterally 14.1 in connection 15.
  • Make sure that the outlet of the extension pieces 14.1 is horizontally and vertically aligned with the chimney outlets. If this is not the case, adjust the position by either reversing the connection extension pieces 14.1 and then reassemble as described previously.
  • Ensure that the activated charcoal filters have been inserted.
Blomberg DKP 2021 — Mounting the hood body diagram (page 7)
Fig. 5 · Mounting the hood body

Page 8 of the Blomberg DKP 2021 user manual — Mounting the hood body
Pagina 8 · clicca per ingrandire
Pagina 8
  • ELECTRICAL CONNECTION
  • Connect the hood to the mains through a two-pole switch having a contact gap of at least 3 mm.
  • Remove the grease filters (see paragraph Maintenance) being sure that the connector of the feeding cable is correctly inserted in the socket placed on the side of the fan.
Blomberg DKP 2021 — Mounting the hood body diagram (page 8)
Fig. 6 · Mounting the hood body
Blomberg DKP 2021 — Mounting the hood body diagram (page 8)
Fig. 7 · Mounting the hood body
  • Upper exhaust Chimney
  • Slightly widen the two sides of the upper chimney and hook them behind the brackets 7.2.1 , making sure that they are well seated.
  • Secure the sides to the brackets using the 4 screws 12c (2,9 x 9,5) supplied.
  • Lower exhaust Chimney
  • Slightly widen the two sides of the chimney and hook them between the upper chimney and the wall, making sure that they are well seated.
  • Fix the lower part laterally to the hood body using the 2 screws 12c (2,9 x 9,5) supplied.

!

Page 9 of the Blomberg DKP 2021 user manual — Control panel
Pagina 9 · clicca per ingrandire
Pagina 9

USE

"(

Control panel

KEY LED FUNCTIONS L 0/1 Light Turns lighting on and off. T1 0/1 Motor on First speed. When pressed for about 1 seconds the motor is switched off.

T2 Speed on Second speed. T3 Speed on Third speed.

T4 Speed Fixed Max. speed Flashing Intensive speed. Suitable for the strongest cooking vapours and odours. The func- tion becomes active when the button is pushed for about 2 sec- onds. After 10 minutes of functioning it turns off automatically. This function can be interrupted by means of pressing any of the buttons.

Page 10 of the Blomberg DKP 2021 user manual —
Pagina 10 · clicca per ingrandire
Pagina 10
Blomberg DKP 2021 —     diagram (page 10)
Fig. 8

L Light Switches the lighting system on and off.

S Led Motor running led.

V1 Motor Switches the extractor motor on and off at low speed. Used to provide a contin- uos and silent air change in the presence of light cooking vapours.

V2 Speed Medium speed, suitable for most operating conditions given the optimum treated air flox/noise level ratio. V3 Intensive Maximum speed, used for eliminating the highest cooking vapour emission,

including long periods.

Page 11 of the Blomberg DKP 2021 user manual — Activated charcoal filter (Recirculation version)
Pagina 11 · clicca per ingrandire
Pagina 11

MAINTENANCE

Grease filters

CLEANING METAL SELFSUPPORTING GREASE FILTERS

  • The filters must be cleaned every 2 months of operation, or more frequently for particularly heavy usage, and can be washed in a dishwasher.
  • Remove the filters one at a time by pushing them towards the back of the group and pulling down at the same time.
  • Wash the filters, taking care not to bend them. Allow them to dry before refitting.
  • When refitting the filters, make sure that the handle is visible on the outside.

Activated charcoal filter (Recirculation version)

REPLACING THE ACTIVATED CHARCOAL FILTER

  • The filter is not washable and cannot be regenerated, and must be replaced approximately every 4 months of operation, or more frequently for particularly heavy usage.
  • Remove the metal grease filters.
  • Remove the saturated activated carbon filter by releasing the fixing hooks.
  • Fit the new filter by hooking it into its seating.
  • Refit the metal grease filters.
  • Lighting LIGHT REPLACEMENT 40 W incandescent light.
  • Remove the metal grease filters.
  • Unscrew the bulbs and replace them with new ones having the same characteristics.
  • Replace the metal grease filters.

Fai una domanda su Blomberg DKP 2021

I possessori del prodotto e il nostro team di solito rispondono entro 24 ore, e la tua domanda sarà utile anche ad altri.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Nessuna domanda ancora per il dispositivo Blomberg DKP 2021

Invia la prima domanda: risponderanno altri possessori o il nostro team.

Documento originale

Blomberg DKP 2021 manuale in PDF

84 pagine·2.7 MB·Cappa aspirante da cucina·PDF
Clicca su qualsiasi pagina in alto per aprirla qui
Pagina 1 / …
100%
Caricamento pagine…