15 SEER USER’ s MANU AL & INST ALLA TION INSTR UCTIONS Single P acka g e Heat Pump - 2 Stage, R-410A Please read this inf or mation thoroughly and become familiar with the capabilities and use of y our appliance bef ore attempting to operate or maintain this unit.
2 Safety Inf ormation ........................................ 4 General Information ..................................... 4 Bef ore Y ou Install this Unit .......................... 4 Locating the Heat pump ............................ 4 Air Duct System .
3 Figure 1. Digital Thermostat Fa n Mode T emperature Selector System Mode ABOUT THE HEA T PUMP Y our heat pump is a unique, all w eather comf or t- control appliance that will heat and cool your home year round and pro vide energy saving comf or t.
4 GENERAL INFORMA TION Single packaged heat pumps are ready f or easy and immediate installation and can be readily connected into the high static duct system of a home. This unit is completely assembled, wired, and run tested at the factory . This heat pump is designed for outdoor installation onl y .
5 HEA T PUMP INST ALLA TION Unpacking the Unit It is recommended that the unit be unpack ed at the installation site to minimize damage due to handling. CA UTION: Do not tip the unit on its side. Oil may enter the compressor c ylinders and cause starting trouble.
6 2. Overlap the collar ends k eeping the small screw holes underneath. 3. Align the holes in the crimped area and install one screw . NOTE: It may be necessary to loosen the f our screws that hold the transition duct in order to install the supply fi tting.
7 Figure 7. Supply Damper A UTOMA TIC DAMPER IS CLOSED WHEN HEA T PUMP IS OFF Figure 6. Return Air Box NO TE: The return air box with g r ille and fi lter (Figure 6) should not be located in heavy tr affi c areas like hallw ays or center of rooms . A good spot is in a cor ner or under a tab le, if a minim um two inch clearance is a vailab le.
8 Figure 8. P ower Entry Low V oltage High V oltage ELECTRICAL CONNECTIONS W ARNING: To av oid electric shock, personal injury , or death, turn off the electric power at the disconnect or the main service panel before making an y electrical connections.
9 Blower Speed F or optimum system performance and comfort, it ma y be necessar y to change the factory speed setting. See T able 4 (page 20) f or factory settings.
10 Thermostat Connections • The Q5RF heat pump is a two stage cooling and heating appliance that requires a 2-stage Cooling/Heating ther mostat. The heat-cool ther mostat pre vents simultaneous oper.
11 Figure 10. T ypical Heat Pump Thermostat Connections T ypical Wiring (Field Supplied) for 2-Stage Cool, 2-Stage Electric Heat T ypical Wiring (Field Supplied) for 2-Stage Cool, 1 Stage Electric Hea.
12 ST ARTUP & ADJUSTMENTS Pre-Start Checklist The f ollowing check list should be observed prior to star ting the unit. Is the unit lev el? Unit should be lev el or slightly slanted tow ard the drain for proper condensate drainage .
13 Cooling Mode When the TEST pins are shor ted together for more than 1 second, the Anti Shor t Cycle Timer will be bypassed. Adjustment of Refrigerant Charge CA UTION: This heat pump contains liquid and gaseous refrigerant under pressure .
14 Refrigerant Charging Charts for Cooling Mode of Operation Figure 11. Charging Chart for 2 ton Units 200 225 250 275 300 325 350 375 400 425 450 475 500 525 550 575 600 70 75 80 85 90 95 100 105 110.
15 Refrigerant Charging Charts for Cooling Mode of Operation - Continued Figure 14. Charging Chart for 5 ton Units 200 225 250 275 300 325 350 375 400 425 450 475 500 525 550 575 600 70 75 80 85 90 95.
16 Q5RF-X24K OUTDOOR TEMPERA TURE (DEG. F) 0 1 02 03 04 05 06 0 Suc. Liquid Disch. Suc. Liquid Disch. Suc. Liquid Disch. Suc. Liquid Disch. Suc. Liquid Disch. Suc. Liquid Disch. Suc. Liquid Disch. Press Press. T emp . Press. Press. T emp. Press. Press.
17 T able 3. Refrig erant Charging T ables f or Heating Mode of Operation - 4 & 5 T on Units Q5RF-X48K OUTDOOR TEMPERA TURE (DEG. F) 0 1 02 03 04 05 06 0 Suc. Liquid Disch. Suc. Liquid Disch. Suc. Liquid Disch. Suc. Liquid Disch. Suc. Liquid Disch.
18 3. Not sutiable on systems that exceed 150V to gr ound. 4. For replacement wires use conductors suitable f or 105°C. 208/230V Q5RF/PPH2RF SERIES SMALL P A CKA GE H/P W/DEMAND DEFROST 2 T ON AND 3 T ON 60HZ/SINGLE PHASE 1. Disconnect all power bef ore servicing.
19 NO TES: FIELD WIRING LEGEND: LOW V OL T AGE HIGH V OL T AGE 208/230V Q5RF/PPH2RF SERIES SMALL P A CKA GE H/P W/DEMAND DEFROST 4 T ON AND 5 T ON 60HZ/SINGLE PHASE 1. Disconnect all power bef ore servicing. 2. For supply connections use copper conductors onl y .
INST ALLER: PLEASE LEA VE THESE INST ALLA TION INSTRUCTIONS WITH THE HOMEO WNER. 7091580 Specifi cations and illustrations subject to change without notice or incurring obligations.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Acnodes Q5RF SERIES è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Acnodes Q5RF SERIES - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Acnodes Q5RF SERIES imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Acnodes Q5RF SERIES ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Acnodes Q5RF SERIES, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Acnodes Q5RF SERIES.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Acnodes Q5RF SERIES. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Acnodes Q5RF SERIES insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.