Page 1 of the Austroflamm Jini user manual — Setting up your stove
Pagina 1 · clicca per ingrandire
Pagina 1

english 5 Jini/Jini Xtra

1. TECHNICAL DATA As a stove of construction type 1, it is possible to connect it to the chimney together with an existing other stove or another hearth for solid fuels, as long as the chimney calculation complies with DIN 4705, Part 3.
Austroflamm Jini — Setting up your stove diagram (page 1)
Fig. 1 · Setting up your stove
TECHNICAL DATA Height1000 mm Width486 mm Depth406 mm Weight Jini/Jini Xtra125/226 kg Flue pipe outlet diameter130 mm Nominal thermal output (EN 13240)4 kW Maximum thermal capacity6 kW Smallest heating capacity2,5 kW Room heating capacity (depending on building insulation)34 – 88 m³
Exhaust values for multiple use of the chimney in accordance with DIN 4705, Part 3 and for the calculation of the chimney measurements in accordance with DIN 4705, Part 2 Fluegas mass flowclosed3,9 g/s Fluegas temperatureclosed343 °C Minimum feed pressure Nominal thermal outputclosed12 Pa at 0.8 times n. ther. outp.10 Pa
2. IMPORTANT INFORMATION The installation and operation information given here is of general nature. National and European standards, local and building regulations as well as fire prevention laws must be observed during the operation of the stove. General safety instructions for the operation of your stove Thoroughly read the entire manual before starting up your stove and observe the caution notices.

Do not lay laundry onto the stove for drying. Laundry hung up to dry must be kept at a safe distance from the stove because of the danger of fire.

The woodstove Jini / Jini Xtra is not suitable for long term heating.

Subject to technical and optical modifications. Formatting and printing errors excepted.

During the operation of your heating unit it is forbidden to use flammable or explosive materials in the same or an adjacent room to the one in which your heating unit is located.

The appliance must be operated with the stove door closed.

Your heating unit must not be moved without approved means of transport with sufficient load-bearing capacity.

The stove door and all fittings for adjusting the stove must be closed, if the appliance is out of use.

Your heating unit is not suitable to be used as a stand or as a ladder.

Setting up your stove

Please keep in mind that your stove’s surface heats up considerably during operation. We therefore recommend wearing a safety mitten when operating your stove.

Austroflamm Jini — Setting up your stove diagram (page 1)
Fig. 2 · Setting up your stove

Required safety distances (Minimum distances – see name plate - in Fig. 2) Jini/Jini Xtra a > 1000 mm b > 270 mm c > 160 mm (a – toward the front in the radiated area) (b – to the side)

Make your children aware of this particular danger and keep them at a distance from the heating unit whenever it is in operation.

(c – to the back) Make sure that the room in which the stove is set up has at least one door or window into the outside or is directly adjacent to such a room. Other fireplaces and extractor hoods must not be operated in the same room as the stove. Floor load capacity Make sure that the load capacity of the supporting construction is sufficient to carry the weight of the entire unit, before the heating unit is installed.

Only burn approved fuels and materials listed in the chapter “Clean Burning”.

The burning or placing of flammable or explosive materials, such as empty spray cans, etc. into the firebox as well as the storage of such materials in the immediate vicinity of your heating unit is strictly forbidden due the danger of explosion.

Do not wear loose or flammable clothing when adding fuel to the fire.

Placing non-heat-resistant objects on the heating unit or in the vicinity of the heating unit is forbidden.

Page 2 of the Austroflamm Jini user manual — 3. CORRECT OPERATION OF YOUR STOVE
Pagina 2 · clicca per ingrandire
Pagina 2

Jini/Jini Xtra 6 english

Combustion air Being the user of the stove you must take care of a sufficient combustion air supply. Sealed-up windows and doors may not allow a sufficient combustion air supply or disturb the draught behaviour of your stove. Please ensure the additional supply of fresh combustion air if necessary. For details please consult your specialist retailer. Make sure that the combustion air intakes are not blocked!

Stove pipe connection For your own safety stringent laws apply for connecting the stove pipes to the chimney. Your professional dealer or distributor knows these laws. Please have your certified retailer carry out the connection of your stove.

3. CORRECT OPERATION OF YOUR STOVE

Approved fuels Dry, well cured and natural wood (hardwood preferred), wood briquettes. Maximum amount of fuel Maximum amount of fuel to be added: 1,3 kg wood or briquettes. Larger amounts of fuel can lead to overheating and thus damage the stove. Clean burning The wood must be dry (relative wood moisture < 15%) and untreated and the right amount of wood must be burned in order to ensure a clean fire that releases only small amounts of emissions. Startup procedures During the first 3-4 operations - at nominal heat output - there may be some odour development and the varnish has not yet hardened. Making a fire For the correct and safe operation of your stove please pay attention of the chimney developing the necessary feed pressure. This must especially be considered before the initial operation (or e.g. after the summer heating break) and during the mid-season heating periods (e.g. at strong wind, etc.). If there is not enough feed pressure, please light only some paper or small kindling first, in order to “warm up” the stove and the chimney. The air inlet must not be covered or closed. Clean grate, empty ash drawer if necessary (watch out for ambers!). Position the lever for the combustion air to the open (“AUF”) position (see fig. 3). Place 2-3 logs (approx. 0,9 kg in total) crossways in the combustion chamber (1) with sufficient distance from each other (min. 2 cm), on top of that place some softwood chippings (0,4) (2) and some ignition aid and light. ‘(3) (see fig. 3)

Close the door! We recommend to let the first load burn down without changing the air lever position. As soon as no visible flames are left (only embers in the combustion chamber), you can put another load of logs (approx. 1,3 kg) in the combustion chamber if desired. When reloading the stove please repeat the procedure as mentioned under “first lighting”: air lever position on “AUF” (= open), open door carefully, place logs, close door.

Austroflamm Jini — 3. CORRECT OPERATION OF YOUR STOVE diagram (page 2)
Fig. 3

Fig. 4: adjust air lever After a few minutes, when the logs burn well on all sides (bright, high flames – see fig. 5), you can adjust the heat output with the air lever (lever on max. position “AUF” = maximum heat output), the flames should be yellow and never look blueish or have black tips (otherwise add more air) – see fig. 4. Never close air supply completely during operation. (danger of flash-fire!) The stove door may be opened only for refuelling or disposing of ashes and is to be closed again afterwards.

Austroflamm Jini — 3. CORRECT OPERATION OF YOUR STOVE diagram (page 2)
Fig. 4
Austroflamm Jini — 3. CORRECT OPERATION OF YOUR STOVE diagram (page 2)
Fig. 5

Figure 3:ignite the fire

symbol figures · symbol figures · symbol figures

Page 3 of the Austroflamm Jini user manual — 3. CORRECT OPERATION OF YOUR STOVE
Pagina 3 · clicca per ingrandire
Pagina 3

english 7 Jini/Jini Xtra

Heating in-between seasons If you heat the stove in between seasons, when the outside temperatures are higher, the flue gases may not be able to escape completely and this may lead to disturbances in the chimney draught, especially if the temperatures are rising suddenly. The stove has to be charged with less wood then and the primary air has to be increased so that the wood can burn down faster (with visible flames) and thus the chimney draught can stabilize.

Chimney fire A chimney fire may occur, due to sooting and deposits in the chimney, if wrong or humid fuel is used. In case of a chimney fire close all air inlets on the fireplace/chimney immediately and call the fire brigade. Please have an expert inspect your chimney for cracks and air-tightness after the burning out of the chimney.

Austroflamm Jini — 3. CORRECT OPERATION OF YOUR STOVE diagram (page 3)
Fig. 6
DescriptionNr.drawingPart number Gasket round 15x8 mm, L=1900 mm12718571 Gasket round Ø 6, L=1420 mm13710696
Austroflamm Jini — 3. CORRECT OPERATION OF YOUR STOVE diagram (page 3)
Fig. 7
DescriptionNr.drawingPart number Bottom left, Keramott1714930 Bottom right, Keramott2714931 Rear, Keramott3714933 Side left, Keramott4714934 Side right, Keramott5714935 Wood retainer, Keramott6720027 Grate7716408 Baffle plate, Keramott8714936

Keramott numbering = installation instructions

Austroflamm Jini — 3. CORRECT OPERATION OF YOUR STOVE diagram (page 3)
Fig. 8
DescriptionNr.drawingPart number Door complete9720087 Door handle10720094 Door glass11720026 Glass cleaner ½ litre--640070 Stove lacquer--650002
Page 4 of the Austroflamm Jini user manual — problem possible reason solution
Pagina 4 · clicca per ingrandire
Pagina 4

Jini/Jini Xtra 8 english

5. SPECIAL FEATURES JINI/JINI XTRA

Xtra heat storing technology

The model Jini Xtra has been equipped with the unique Xtra heat storing technology. This technology is based on the patented Heat Memory System, but also on the special flue gas guidance and the convection air which can be regulated or shut off completely. Consequently a fast heating system is being combined with an extraordinarily efficient heat storing. The convection air can be regulated according to demand with the attached lever (see picture). The more the convection air outlets of the top plate are open, the faster heat but less heat storing can be reached. A closed top plate will however lead to slow heat and longer heat storing.

Austroflamm Jini — 5. SPECIAL FEATURES JINI/JINI XTRA diagram (page 4)
Fig. 9

Our hint: while the fire still burns let the convection air outlets open; close them after the fire has burnt down in order to reach a steady heat emission. Operation with external air supply

The German institute for constructional engineering (DIBT) has given the Jini/JiniXtra the general technical approval for operation with exteranl air supply. If the combustion air is being supplied directly to the furnace by an air-tight pipe including closing mechanism from the outside, then the stove may be used in residential property with mechanical ventilation. If the stove in being used like that, a multiple stove installation on the same chimney is forbidden. This stove has been approved by the German DIBT

problem possible reason solution

generally: door glasses must be cleaned with Austroflamm glass cleaner from time to time (depending on the frequency of use)

contact your chimney sweep (elongate chimney/draught metering)

please operate air lever according to user's instructions (if secondary air is closed, the door glass soots rather fast)

door glass gets sooty too fast

incorrect use of the combustion air supply lever

wood logs are too large keep to the max. fuel quantity according to user's instruction operating temperature was not reached

more fuel, use dry wood (< 15 % residual moisture), attend air regulation

chimney draught not sufficient contact your chimney sweep (elongate chimney/draught metering)

stove does not get enough combustion air

stove is sooted inside more fuel, use dry wood (< 15 % residual moisture), attend air regulation

baking phase of the varnish there may be some odour development during the first operations

stove smells strongly and there is smoke on the outside surface

stove is dusty/dirty cleaning before the heating season starts!

inspect joints and seal up again if necessary

chimney draught no sufficient, flue pipe connection leaky

check chimney draught, examine operating - for info video follow: http://www.austroflamm.com/de/Video/index.html

exhaust gas emission while putting more wood on the fire and during operation

put more fuel wood into the combustion chamber only if there are only embers left (no more visible flame)

the stove door was opened before the wood has burnt down to embers

bad chimney draught

Fai una domanda su Austroflamm Jini

I possessori del prodotto e il nostro team di solito rispondono entro 24 ore, e la tua domanda sarà utile anche ad altri.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Nessuna domanda ancora per il dispositivo Austroflamm Jini

Invia la prima domanda: risponderanno altri possessori o il nostro team.

Documento originale

Austroflamm Jini manuale in PDF

20 pagine·1.1 MB·Riscaldatore·PDF
Clicca su qualsiasi pagina in alto per aprirla qui
Pagina 1 / …
100%
Caricamento pagine…