IT
Austroflamm logo
Manuale d'uso ufficiale

Austroflamm Diva

16 pagine·983 KB·Riscaldatore·PDF·ENNLJA
Austroflamm Diva
Indice dei contenuti 3 sezioni Setting Up Your Stove · Floor Load Capacity · 3. CORRECT OPERATION OF YOUR STOVE MostraNascondi
Page 1 of the Austroflamm Diva user manual — Setting Up Your Stove
Pagina 1 · clicca per ingrandire
Pagina 1
Smallest heating capacity3 kW Room heating capacity (depending on building insulation)35 – 90 m³
Exhaust values for multiple use of the chimney in accordance with DIN 4705, Part 3 and for the calculation of the chimney measurements in accordance with DIN 4705, Part 2 Fluegas mass flow closed5,5 g/s Fluegas temperature closed310 °C Minimum feed pressure closed Nominal thermal output at 0.8 times n. ther. outp.0,10 mbar 0,08 mbar
TECHNICAL DATA Height1153 mm Width492 mm Depth416 mm Weight151 kg Weight with ceramic shell161 kg Flue pipe outlet diameter130 mm Nominal thermal output (DIN 18891)5 kW Maximum thermal capacity 7 kW
2. IMPORTANT INFORMATION The installation and operation information given here is of a general nature, exact regulations may vary from country to country. The rules in force in your country should always take precedence. General Safety Instructions for the Operation of Your Stove • Thoroughly read the entire manual before starting up your stove and ensure compliance with the warnings.

heating unit is strictly forbidden due the danger of explosion.

  • Do not wear loose or flammable clothing when adding fuel to the fire.
  • Placing non-heat-resistant objects on the heating unit or in the vicinity of the heating unit is forbidden.
  • Do not lay laundry onto the stove for drying.
  • Laundry hung up to dry must be kept at a safe distance from the stove because of the danger of fire.

Subject to technical and optical modifications. Formatting and printing errors excepted.

  • Your heating unit may not be moved without approved means of transport with sufficient loadbearing capacity.
  • When operating your heating unit it is forbidden to use flammable or explosive materials in the same or an adjacent room to the one in which your heating unit is located.
  • Your heating unit is not suitable to be used as a stand or as a ladder.
  • The burning of fuel releases thermal energy that leads to a substantial heating up of the surface of the heating unit, the doors, the parts mounted on the door, door glass, flue pipe and in some cases the front wall of the heating unit. Do not touch any of these surfaces without respective protective clothing or without the help of accessories such as heat-resistant gloves or a cold hand.

Setting Up Your Stove

Safety Clearances (Minimum Distances in Fig. 2) 1. To nonflammable objects: a > 400 mm b > 200 mm 2. To flammable objects and to supporting walls of reinforced-concrete construction with convection shell:

  • Make your children aware of this particular danger and keep them at a distance from the heating unit whenever it is in operation.

a > 600 mm b > 200 mm (a – toward the front in the radiated area) (b – to the side and to the back) Make sure that the room in which the stove is set up has at least one door or window to the outside or is directly adjacent to such a room.

  • Only burn approved fuels and materials listed in the section entitled Clean Burning.
  • The burning or introduction of flammable or explosive materials, such as empty spray cans and the like into the firebox as well as the storage of such materials in the immediate vicinity of your

Diva 4 english

Page 2 of the Austroflamm Diva user manual — 3. CORRECT OPERATION OF YOUR STOVE
Pagina 2 · clicca per ingrandire
Pagina 2

Floor Load Capacity

Stovepipe Connection For your own safety stringent laws apply to the connecting of the stovepipe to the chimney. Your professional dealer or distributor knows these laws. Please have your certified retailer carry out the connection of your stove.

Before the heating unit is installed, make sure that the load capacity of the supporting construction is sufficient to carry the weight of the entire unit.

3. CORRECT OPERATION OF YOUR STOVE

Initial startup of your stove Your stove was treated with a special environmentally friendly lacquer. The lacquer surface is still soft at the time the stove is shipped. The lacquer will harden when your stove is used for the first time. The lacquer surface may not be touched when it is heated for the first time. The stove must be initially heated to a high temperature for at least 1.5 hours. Visible vapors may appear during the hardening of the lacquer. For this reason it will be necessary to open windows during initial operation in order let the vapors escape into the outdoors. PLEASE TAKE NOTE: It takes several heating sessions before for your stove releases only the pleasant smell of burning wood. Approved Fuels Dry, well cured and natural wood, wood briquettes. Maximum Amount of Fuel Maximum amount of fuel to be added: 1,3 kg wood or 1,5 kg wood briquettes. Larger amounts of fuel can lead to overheating and thus damage the stove. Clean Burning The wood must be dry (relative wood moisture < 15%) and untreated and the right amount of wood must be burned in order to ensure a clean fire that releases only small amounts of emissions. Making a Fire Prepare everything you need for starting the fire— soft wood chips, igniter materials (such as Thermohit wood/coal igniter), uncoated paper, wood. Figure 1 provides a good overview of the materials you will need.

Austroflamm Diva — 3. CORRECT OPERATION OF YOUR STOVE diagram (page 2)
Fig. 1

Figure 3: Heating Material Open the primary and secondary air all the way. Move both sliders. See Figure 2. Open the stove door. Lay uncoated paper on the floor of the firebox. Lay soft wood chips onto the paper. Lay one or two logs of wood on the wood chips.

Austroflamm Diva — 3. CORRECT OPERATION OF YOUR STOVE diagram (page 2)
Fig. 2

Figure 4: Igniting the Fire Light the paper. Close the firebox. As soon as the chips are burning well, close the primary air supply.

english 5 Diva · symbol figures

Page 3 of the Austroflamm Diva user manual — Floor Load Capacity
Pagina 3 · clicca per ingrandire
Pagina 3
Austroflamm Diva — Floor Load Capacity diagram (page 3)
Fig. 3 · Floor Load Capacity

As soon as the wood logs are burning well, you can regulate the heating capacity with the secondary air slider. (Slider set to the maximum (“AUF”) setting produces maximum heat – see Figure 2.) When adding wood to the fire, follow the same procedure as when igniting the fire: Open primary air, open secondary air, carefully open firebox door, lay wood on the fire, close the firebox door. Wait until the added wood catches fire and is burning. Then close the primary air. Subsequently regulate the fire with the secondary air supply.

Figure 5Close the Primary Air
DescriptionNr. drawingPart number Flat gasket 8 x 2 x 610 mm Round gasket d= 12 mm36 33710096 710338
Description Nr. drawing Part number Diva Keramott rear6716356 Diva Keramott bottom right2716355 Diva Keramott bottom left1716354 Diva Keramott lateral left5716645 Diva Keramott lateral right9716646 Diva Keramott rear baffle plate7716358 Diva Keramott front baffle plate8716357 Diva Keramott wood retainer4712642 Diva/G4 grate3716408

Keramott numbering = installation instructions!

DescriptionNr. drawingPart number Diva door glass35712017 Stove lacquer--650002 Wood/coal igniter--640067 Glass cleaner ½ litre--640070

Diva 6 english

Fai una domanda su Austroflamm Diva

I possessori del prodotto e il nostro team di solito rispondono entro 24 ore, e la tua domanda sarà utile anche ad altri.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Nessuna domanda ancora per il dispositivo Austroflamm Diva

Invia la prima domanda: risponderanno altri possessori o il nostro team.

Documento originale

Austroflamm Diva manuale in PDF

16 pagine·983 KB·Riscaldatore·PDF
Clicca su qualsiasi pagina in alto per aprirla qui
Pagina 1 / …
100%
Caricamento pagine…