1.2 Charger functionality

The LP 10.0 microprocessor controlled charger with smart 6-setting charging mode allows lead batteries / storage batteries to automatically be charged quickly and gently. Once the specific battery type has been determined the LED display will show the lead storage battery's current charging status. The additional activation program will reactivate deep discharged storage batteries. Gentle charging process may extend the battery's life.

Congratulations on your purchase of a new „LP 10.0 charger“. Thank you for your trust. To ensure optimal charger operation, performance and safety, please read the operator's manual prior to use. This will allow you to enjoy your equipment for a long time.

1.1 What do these symbols mean?

1.3 Intended use

Refer to operator's manual!

The LP10.0 charger is intended solely for charging and trickle charging 6, 12 and 24 V (Volt) lead acid storage batteries.

This device may be used to charge the following types of lead acid storage batteries:

Indicates dangerous electrical voltage! Danger!

  • Lead acid storage batteries (open systems, wet)
  • Maintenance free lead acid storage batteries
  • VRLA storage batteries (valve-regulated lead
AEG LP 10.0 - 97100 — 1.0 PREFACE diagram (page 2)
Fig. 1

Explosion hazard! Indicates explosive materials!

Fire hazard! Indicates flammable materials!

Dispose of equipment, batteries and packaging in an environmentally friendly manner!

Do not charge battery types not specified above! Any other use or modification of the LP 10.0 charger is not as intended and may result in life-threatening hazards! The charger is intended for private use only.

This equipment complies with EU directive 2004/108/EC

Devices with protective class II protective insulation

See page 32 for additional information about symbols, units and abbreviations.

Dear Customer, · (absorption glass mat)

Page 3 of the AEG LP 10.0 - 97100 user manual — 2.0 SAFETY NOTICES
Pagina 3 · clicca per ingrandire
Pagina 3

1.4 Connecting and disconnecting the LP 10.0 charger

2.0 SAFETY NOTICES

  • First connect the positive (+) red

2.1 General safety notices

clamp to the positive (+) battery terminal. ▪Now connect the negative (-) black

clamp to the negative (-) battery terminal. ▪Only now plug the power plug into a

suitable 230 V alternating current outlet.

  • First unplug the power cable from the mains.
  • Then disconnect the negative (-) black

clamp from the negative (-) battery terminal. ▪Then disconnect the positive (+) red clamp from

the positive (+) battery terminal.

2.1.1 Keep charger away from children! Children do not understand or recognize the potential risks associated with hand-ling electrical equipment. Never allow the charger to end in the hands of children and store out of the reach of children. Children may swallow or choke on small parts. Children may be injured when using the charger. Keep packaging away from children.

1.5 LP 10.0 charger features

  • Charger for all popular 6, 12 and 24 V
  • automotive batteries (AutoSelect function / automatic battery recognition)
  • Max. charging current 10 A
  • Microprocessor
  • Smart 6-setting charging mode

2.1.2 Keep these instructions throughout the product's life.

2.1.3 This device is not intended to be used by persons (including children) with limited physical, sensory or mental capacities or lacking experience and / or knowledge unless supervised by a person responsible for their safety or instructed by such on how to use the equipment.

(IOIUOUOIUOa curve) ▪No battery removal required (please refer to

Item 2.3 on page 22 and 23!) ▪Automatic charging level adjustment.

Fully automatic charging, diagnostic, rescue and maintenance function ▪With display (charging status, battery voltage

and error messages) ▪Battery charging status displayed as percentage

2.1.4 Do not use the charger to power electrical equipment, vehicles or other external devices.

and as a bar graph. Holder for clamps and practical cable storage compartment

Connecting the charger · Disconnecting the charger

Page 4 of the AEG LP 10.0 - 97100 user manual — 2.0 SAFETY NOTICES
Pagina 4 · clicca per ingrandire
Pagina 4

2.1.5 Always use protective eyewear, protective gloves and closed clothing to cover the entire body when handling lead storage batteries.

2.2.3 Position the supply cable and the terminal cable to avoid tripping or damage to the cable, e.g. due to objects with sharp edges!

2.1.6 Warning! Never charge damaged, non-rechargeable or frozen batteries / storage batteries or dry cell batteries!

2.2.4 Never operate the charger if damaged or malfunctioning!

2.2.5 Any repairs to the charger must be per- formed by a qualified electrician / qualified professional.

2.1.7 If you are unsure about the use or functionality of the charger, please consult a qualified professional.

2.2.6 Never disassemble, repair, or modify (alter) the equipment.

2.1.8 Never place the electrical charger in a wet location. Never expose the equipment to precipitation, dust, direct sunlight or splash water.

2.2.7 The work area must be well ventilated when starting the charger indoors. Never place the charger atop the battery / storage battery whilst charging!

2.1.9 The device will heat up during operation. Always place the charger in a safe, well ventilated location away from flammable objects.

2.2.8 Always ensure a safe footing when putting down the charger. Position the supply cable to prevent any interference. Never lay the cable across hot surfaces during charging!

2.1.10 Never wear metallic body jewellery when using the charger and battery. Doing so could result in burns!

2.1.11 Routinely monitor the charger throughout the charging process!

2.2.9 Attention - danger! Avoid any type of open fire and sparks during charging! Charging releases explosive gasses in the vicinity of the battery / storage battery which could explode.

2.2.10 Never operate the charger if it has been dropped or otherwise damaged. Have it examined or repaired by a qualified electrician!

2.2 LP 10.0 charger safety notices

2.2.11 Never use other cables or accessories. Never extend the battery charging cables with the clamps!

2.2.12 Be sure the charger and clamps contain no moisture. Never connect the battery clamps to the battery with wet hands and / or both hands simultaneously!

2.2.1 Attention - risk of injury! Always ensure the equipment is stored in a safe location. Never expose the equipment to oil, grease, moisture, rain or other wet ambient conditions. Avoid water or other liquids from spilling or dripping onto the equipment. Incoming water will cause an electrical short circuit and may damage the equipment.

2.2.13 Always ensure ample clearance around the charger during operation to ensure proper ventilation. Never cover the charger with any objects during charging!

2.2.14 Avoid the skin coming in contact with battery terminals, battery clamps or ring connectors whilst the equipment is connected to alternating current!

2.2.2 Never expose the charger to direct sunlight - doing so may result in overheating!

Page 5 of the AEG LP 10.0 - 97100 user manual — 2.0 SAFETY NOTICES
Pagina 5 · clicca per ingrandire
Pagina 5

2.2.15 Always disconnect battery clamps and charger from the vehicle before starting the vehicle! After using the charger always disconnect from alternating current!

2.3 Safety notices for charging vehicles and boats

2.2.16 Never use the cable to carry the charger or pull on it. Always disconnect the equipment from the power supply by the plug, never the cable!

2.3.1 Before charging secure the vehicle to prevent it from rolling away. Attention - Risk of injury and property damage! Always engage the handbrake and put into gear! For automatic trans- missions put the vehicle into “Park” and engage the handbrake!

2.2.17 The charger requires an input voltage of 230 V / AC for operation.

2.2.18 Never allow liquids to enter the equip- ment! Never immerse the equipment in fluids! Only operate the charger when dry.

2.2.19 Never charge defective batteries! The following indicate a defective battery: ▪Thermal or mechanical distortion

2.3.2 Never operate or start vehicles in the same space whilst charging!

2.3.3 When charging marine batteries always remove the battery!

  • of the battery housing or attachments
  • Insufficient fluid levels inside the cells
  • Fluids leaking from the battery
  • Smell of gas, particularly near the battery

2.3.4 Always follow safety instructions when the vehicle is jacked up, hoisted or similar!

2.3.5 Never permanently mount the charger in vehicles!

2.2.20 Attention! Explosion hazard when gas odours are present! Immediately ensure effective ventilation! Do not switch off the equipment and do not disconnect the terminals from the battery!

2.3.6 Caution! Risk of electrical current near the vehicle's ignition coils, distributor cap, ignition cables, spark plugs and electrical components!

2.2.21 Never turn and hold lead acid batteries above your head! Risk of chemical burns!

2.3.7 Always follow the vehicle manufacturer's safety instructions and operator's manual.

2.2.22 Only charge lead acid batteries! Never use the LP 10.0 charger for non- rechargeable or other battery types.

2.3.8 Only operate the charger in a safe environ- ment! Keep clothing, hair, limbs and the charger away from moving and hot engine and vehicle parts!

2.2.23 Emergency mode! The charger operating mode can be manually interrupted using the button .

2.3.9 Avoid vibration, pressure loads and other mechanical stressors which may impact the charger!

AEG LP 10.0 - 97100 — 2.0 SAFETY NOTICES diagram (page 5)
Fig. 2

2.3.10 Short circuit hazard! Never join the two battery clamps of the charger!

2.3.11 If the battery must be removed from the vehicle for charging, be sure to following the notices in the vehicle manufacturer's operator's manual!

Page 6 of the AEG LP 10.0 - 97100 user manual — 3.0 PRODUCT DESCRIPTION
Pagina 6 · clicca per ingrandire
Pagina 6

2.3.12 In the event of malfunction and damage to the charger or battery during operation, immediately disconnect the equipment from the 230 V alternating current mains source!

2.4.5 Before charging inspect the battery for damage! Never charge defective batteries! On lead acid batteries with vent caps always first check the level of battery fluids. If the fluid level is low, add distilled water to the battery cells up to the level recommended by the battery manufacturer. Attention - always wear protective clothing!

2.3.13 When not in use always unplug the device from the 230 V alternating current mains source!

2.3.14 Never add fluids to the battery during charging!

2.4.6 Clean battery terminals before charging! Caution - risk of electrical shock!

2.4.7 The charging time for the respective battery / storage battery depends on the capacity.

2.4 Storage battery / battery safety notices

3.0 PRODUCT DESCRIPTION

2.4.1 Always wear protective eyewear, protective gloves and closed clothing to cover the entire body when handling lead storage batteries!

2.4.2 Avoid any contact with caustic battery acid! If your body comes into direct contact with battery acid, immediately thoroughly flush the affected area with water and seek medical advice! In the event battery acid comes into contact with the eyes, immediately flush with running clear water for several minutes. In this case also seek immediate medical attention or a hospital emergency room!

3.1 Contents

1 Charger LP 10.0 1 Operator's Manual

After unpacking immediately check all parts are included and inspect all parts for damage!

2.4.3 If the battery must be removed from the vehicle for charging, be sure the ignition and any loads in the vehicle are powered off! First remove the negative terminal (black cable) from the battery. Follow the operator's manual and the vehicle manufacturer's safety instructions!

Do not use the charger if damaged or if the operator's manual is missing!

Illustration may slightly differ from product. Subject to change for the purpose of technical advances. Decorations not included.

2.4.4 Follow the battery manufacturer's operating and safety instructions!

Page 7 of the AEG LP 10.0 - 97100 user manual — B
Pagina 7 · clicca per ingrandire
Pagina 7

3.2 Product overview

Battery charge indicator Error message, incorrect battery clamp polarity Unit % (percent) indicating battery charge level achieved Left segment display Right segment display Unit V (Volt)

AEG LP 10.0 - 97100 — 3.0 PRODUCT DESCRIPTION diagram (page 7)
Fig. 3

3.4 What are the various LED display symbols?

AEG LP 10.0 - 97100 — 3.0 PRODUCT DESCRIPTION diagram (page 7)
Fig. 4

Left compartment with battery clamp fixture Handle Storage shelf at the back of the equipment for power cable and terminal cable. Right compartment with battery clamp fixture Power cable with power plug “Emergency Mode” button to manually start and interrupt the charging process LED Display

A. Positive / negative symbol will flash.

Incorrect battery clamp polarity.

AEG LP 10.0 - 97100 — 3.0 PRODUCT DESCRIPTION diagram (page 7)
Fig. 5

B

B. Charger is ready for use. The two bars in the display will flash.

3.3 LED display and symbols

AEG LP 10.0 - 97100 — B diagram (page 7)
Fig. 6
AEG LP 10.0 - 97100 — B diagram (page 7)
Fig. 7

C. The segments are turning. Automatic battery detection may take up to 5 minutes.

11 12 13

Page 8 of the AEG LP 10.0 - 97100 user manual — P
Pagina 8 · clicca per ingrandire
Pagina 8
AEG LP 10.0 - 97100 — 3.0 PRODUCT DESCRIPTION diagram (page 8)
Fig. 8
AEG LP 10.0 - 97100 — 3.0 PRODUCT DESCRIPTION diagram (page 8)
Fig. 9
AEG LP 10.0 - 97100 — 3.0 PRODUCT DESCRIPTION diagram (page 8)
Fig. 10

D

E

F

D. The equipment automati- cally detected a voltage of 6 V.

E. The equipment automati- cally detected a voltage of 12 V.

F. The equipment automati- cally detected a voltage of 24 V.

AEG LP 10.0 - 97100 — D diagram (page 8)
Fig. 11

G

AEG LP 10.0 - 97100 — G diagram (page 8)
Fig. 12

H

AEG LP 10.0 - 97100 — H diagram (page 8)
Fig. 13

G. The charger is initiating charging mode. “CH” will be displayed for some time.

H. After displaying “CH” the charging status will be indicated in percentages.

I. The charge percentage will be displayed up to 90 %.

AEG LP 10.0 - 97100 — H diagram (page 8)
Fig. 14

J

AEG LP 10.0 - 97100 — J diagram (page 8)
Fig. 15

K

AEG LP 10.0 - 97100 — K diagram (page 8)
Fig. 16

L. The battery charge is at 100 %. K. The charger switches to trickle charging mode. J. The charger switches to slow charging.

AEG LP 10.0 - 97100 — K diagram (page 8)
Fig. 17
AEG LP 10.0 - 97100 — K diagram (page 8)
Fig. 18
AEG LP 10.0 - 97100 — K diagram (page 8)
Fig. 19

N

O

M. The minimum battery voltage required to start charging has not been reached.

N. The battery is fully charged. Unable to recharge the battery.

O. The electric circuit is not closed. Cables are discon- nected.

AEG LP 10.0 - 97100 — N diagram (page 8)
Fig. 20
AEG LP 10.0 - 97100 — N diagram (page 8)
Fig. 21
AEG LP 10.0 - 97100 — N diagram (page 8)
Fig. 22

P

Q

R

P. Faulty battery with high resistance. Unable to charge battery.

R. Short circuit. Q. Battery voltage higher than 29.4 V or battery clamps were disconnected during charging.

Page 9 of the AEG LP 10.0 - 97100 user manual — 7,1 V 6,7 V 6,7 V
Pagina 9 · clicca per ingrandire
Pagina 9
AEG LP 10.0 - 97100 — 6 V charging mode diagram (page 9)
Fig. 23 · 6 V charging mode
AEG LP 10.0 - 97100 — 6 V charging mode diagram (page 9)
Fig. 24 · 6 V charging mode

S

T

S. Charger is overheated. The equipment will switch off above 85 C. °

T. The battery voltage is less than 3.5 V in 12 and 24 V batteries. Battery defective.

3.5 6-setting charging mode diagram for 6, 12 and 24 V batteries

Phase 1Battery detection
Phase 2Gentle charging
Phase 3Rapid charging up to 90 %
Phase 6Battery charge is at 100 %
Phase 5Trickle charging
Phase 4Slow charging

6 V charging mode

7,1 V 6,7 V 6,7 V

6 V 6,5 V

Page 10 of the AEG LP 10.0 - 97100 user manual — 6 V charging mode
Pagina 10 · clicca per ingrandire
Pagina 10
AEG LP 10.0 - 97100 — 6 V charging mode diagram (page 10)
Fig. 25 · 6 V charging mode
AEG LP 10.0 - 97100 — 6 V charging mode diagram (page 10)
Fig. 26 · 6 V charging mode
Page 11 of the AEG LP 10.0 - 97100 user manual — B
Pagina 11 · clicca per ingrandire
Pagina 11
AEG LP 10.0 - 97100 — 4.1 Start charging 4.0 OPERATION diagram (page 11)
Fig. 27 · 4.1 Start charging 4.0 OPERATION

4.1 Start charging 4.0 OPERATION

B

1. Preparation Do not yet connect the charger to a 230 V alternating current outlet! Ensure the room and battery surroundings are well ventilated!
6. Battery detection mode and possible error messages C. During this charging phase the battery voltage is being detected. This detection mode may take a few minutes. The display will read and one individual segment of the digits 00 will also be turning.
2. Connect red clamp First connect the positive (+) red clamp to the positive (+) battery terminal. A plus sign (+) must be visible near the battery terminal.
3. Connect black clamp Now connect the negative (-) black charging clamp to the negative (-) battery terminal. A minus sign (-) must be visible near the battery terminal.

Attention! If the battery is intact charging will start once the battery voltage has been detected. (go to step 7, page 30!). Figures C - L on pages 24 and 25 indicate the normal charging process! If the battery is defective or deep discharged or other errors occur the display will show the following depending on the battery state: Display M, N, O, P, Q, R, S, T - see pages 28 - 30!

4. Correct polarity Verify the two charging clamps are well connected with the correct battery terminals. Clean off any residue on battery terminals. Caution - risk of electrical shock!

A. If the polarity of the charging clamps is reversed the supply current to the battery will be inter-rupted. The display will read . The symbol will flash.

M. If the charger is connected to the battery but unable to detect a voltage the display will be blank. You may then try manually starting the charging process by pressing the emergency mode button . If the battery voltage then rises to above 3.5 V within a few minutes, charging will continue normally. If the voltage remains below this level charging will be suspended and the display will read . You may now discon- nect the charger from the battery and reconnect it to rule out the error being caused by the equipment being incorrectly connected to the battery (also refer to Item 1.4 “Quick guide for connecting and disconnecting the charger“ on page 20!)

AEG LP 10.0 - 97100 — B diagram (page 11)
Fig. 28
5. Stand by B. Now plug the mains plug into a suitable 230 V alternating current outlet. The display will read . The charger is ready for use.

B

Page 12 of the AEG LP 10.0 - 97100 user manual — N
Pagina 12 · clicca per ingrandire
Pagina 12

If the display is again blank, you may again try to manually start the charging process with the emergency mode button . If the display again reads the charger has determined the battery to be defective. The defective battery can no longer be charged!

O. If the battery was disconnected from the charger during the charging process or a circuit is open (e.g. if a battery clamp has slipped off) the equipment will switch off and the display will read . Check the clamps are correctly seated with proper contact!

O

AEG LP 10.0 - 97100 — O diagram (page 12)
Fig. 29
AEG LP 10.0 - 97100 — O diagram (page 12)
Fig. 30

O

P. If the equipment detects a battery with high resistance, charging will not be started. This problem often occurs with old batteries. The display reads .

Features of the Emergency Mode button: 1. During normal operation the emergency mode button may be pressed to suspend charging, immediately ending energy from being supplied to the battery. 2. If the charger is connected to the battery but the display is blank the charging process may be started manually by pressing the emergency mode button (also see Item , page 28).

P

AEG LP 10.0 - 97100 — P diagram (page 12)
Fig. 31

P

Q. If the equipment determines the battery voltage to be higher than 29.4 V or the connection between charger and battery is interrupted during charging the display will read . Charging will not be started.

If the charger has determined a battery to be defective or the battery is already fully charged the charging process is already completed in both cases and pressing the emergency mode button will have no effect!

Q

AEG LP 10.0 - 97100 — Q diagram (page 12)
Fig. 32

Q

R. If the battery causes a short circuit or it is caused by improper use, the charging process will be interrupted and the display will read .

R

R

N. If a battery was just recently fully charged recharging the battery is not recommended. When connecting a fully charged battery to the charger, charging will not be started. The display will read .

N

S. The charger's overheat protection will switch off the device at temperatures above 85 C. Allow the equipment to cool down and repeat the charging process. Be sure the equipment is well ventilated, never cover. Avoid direct sunlight and heat sources which may impact the charger.

N

Page 13 of the AEG LP 10.0 - 97100 user manual — G H
Pagina 13 · clicca per ingrandire
Pagina 13
AEG LP 10.0 - 97100 — 8 J diagram (page 13)
Fig. 33

S

G

T. If the battery voltage is between 1.5 V and 3.5 V the charger will attempt to increase the voltage within a few minutes so that regular charging can automatically be continued. If this fails the display will read and charging will be suspended. However, since the equipment detected a proper connection with the battery no further steps may be taken. The battery is defective and can no longer be charged!

H

9. Slow charging J. Once the battery charge reaches 90 % the equipment automatically switches to slow charge. The remaining capacity will now be gently charged at a lower voltage. This mode will be indicated by and the battery charging bar .

T

8 J

AEG LP 10.0 - 97100 — T diagram (page 13)
Fig. 34

T

J 8

10. Trickle charging mode K. Once the battery is almost fully charged the charger will activate “ Trickle Charging “ mode. The voltage and amperage will now be adjusted for the charging process. The display will read .
7. Battery voltage recognised D, E, F. If the equipment automatically detects an operating voltage of 6, 12 or 24 V, this information will be shown in the display. For a 12 V battery, for example, the display will briefly read . The battery condition will also be shown. Charging will start after this battery review.

K

AEG LP 10.0 - 97100 — K diagram (page 13)
Fig. 35

E 8

K

AEG LP 10.0 - 97100 — E 8 diagram (page 13)
Fig. 36

E 8

11. Charging complete L. Once the battery charge is at 100 % the display will read . Charging will now be stopped and the battery can be disconnected from the charger. Always first disconnect the power cable from the mains current. Then disconnect the negative (-) black clamp from the negative (-) battery terminal. Finally, disconnect the positive (+) red clamp from the positive (+) battery terminal.
8. Charging G, H, I. The respective battery voltage of 6, 12 or 24 V will briefly be displayed. The charger will start charging and the display will read for some time. After charging to 10 % will be displayed, charging will now continue in rapid mode until the display reads to confirm the charge has reached a level of 90 %.

G H

AEG LP 10.0 - 97100 — G H diagram (page 13)
Fig. 37
Page 14 of the AEG LP 10.0 - 97100 user manual — T
Pagina 14 · clicca per ingrandire
Pagina 14

4.2 Troubleshooting

Solutions, corrective action Possible causes Error / Failure

Not connected to 230 V alternating current. The charger is connected to power. The display is blank, not charging.

Check the fuses of the mains connection and ensure the charger is connected to a 230 V alternating current power supply.

Please consult a qualified professional. Charger defective.

The battery is deep discharged. The battery is connected to the charger and the charger is switched on. Not charging.

Press the "Emergency mode” button to start charging manually. The charger is unable to detect the battery voltage.

This could be a software error. The LED shows symbols not listed in the operator's manual.

Disconnect the charger from the mains and repeat the charging process.

Charger defective.

Please consult a qualified professional.

The charger is unable to detect the battery voltage. Display read-out

Press the "Emergency Mode“ button to start charging manually.

Check for proper contact and correctly seated clamps. The battery was disconnected from the charger during charging: open circuit

O

P

Unable to charge battery. The charger has detected a defective battery with high resistance.

Unable to charge battery. The charger has detected a battery voltage above 29.4 V. Display read-out

Q

Short circuit. Display read-out

R

Check the battery. Please note the instructions for use inside the operator's manual.

S

Allow the charger to cool off and repeat the process. Overheat protection has switched off the charger at 85 C or higher.

Unable to charge battery. Battery defective! The voltage of a 12 or 24 V battery is below 3.5 V. Display read-out

T

Show 4 more labels / short text on this page
Display read-out · Display read-out · Display read-out · °
Page 15 of the AEG LP 10.0 - 97100 user manual — 5.0 MAINTENANCE AND CARE
Pagina 15 · clicca per ingrandire
Pagina 15

5.0 MAINTENANCE AND CARE

6.0 TECHNICAL SPECIFICATIONS

5.1 Cleaning, maintenance and storage

Device description: Charger LP 10.0 Item number: 97100 Dimensions: approx. 270 x 150 x 190 mm (l x w x h mm) Weight: approx. 2.3 kg Display: LED display Input voltage: 230 V 50 Hz / 2 A (V = Volt, Hz = Hertz,

5.1.1 Caution! Power off charger (button ) and disconnect from 230 V alternating current before cleaning the equipment!

cycles per second) Output voltage / 6 V / 10 A, 12 V / 10 A, Output current: 24 V / 6 A DC (A = ampere, DC = direct current) Efficiency: > 80 % Battery types: 6 V / 12 V / 24 V Lead acid batteries: ▪Lead acid storage

5.1.2 Clean the charger with a dry cloth. Do not use liquids or harsh cleaning agents as this may result in discoloration or damage to the equipment surface, potentially damaging the charger! Prevent any fluids from entering the equipment! Never immerse the equipment in fluids! Only operate charger when dry.

5.1.3 Always store charger in a dry location! Moisture could damage the charger's electronic circuit!

  • batteries
  • Lead gel storage batteries
  • Mat / AGM storage

5.1.4 Never expose charger to extreme temperature fluctuations! Condensation can damage the electronic circuit!

  • batteries
  • VRLA storage batteries
  • Maintenance free lead

5.1.5 When storing the charger only loosely fold cables and store in the charger's storage shelf to avoid damage to the cable. Secure battery clamps to the designated brackets inside the left and right charger compart- ment (see page 24, figure 1).

acid storage batteries Battery capacity: 1.2 - 225 Ah (ampere-hours) Operating 0 C - 50 C (Celsius) temperature: Charging curve: IOIUOUOIUOa IP Class IP65, waterproof (safety class):

4 1 ° °

Devices with Protective Class II protective insulation This equipment complies with EU directives ▪Low Voltage

Directive (2006/95/EC) ▪Electromagnetic

~ · compatibility directive (2004/108/EC)

Page 16 of the AEG LP 10.0 - 97100 user manual — 7.0 DISPOSAL
Pagina 16 · clicca per ingrandire
Pagina 16

7.0 DISPOSAL

8.0 WARRANTY AND SERVICE

7.1.1 Always dispose and recycle according to the law. Please consult your municipality or a waste manage- ment company. Dispose of this equipment according to the EU Waste electrical and electronic equipment directive 2002/96/EC- WEEE.

In the event of damage, repairs or other problems with this product please consult the retailer where the purchase was made or a professional.

The general warranty terms pertain to manufacturing and material defects. Please return defective products to the retailer where the purchase was made.

7.1.2 When disposing of lead acid batteries please follow manufacturer specifications and legal regulations! Please consult your municipality or a waste management company.

  • To ensure quick processing of your claim you will also need:
  • A copy of the receipt with date of purchase.
  • Reason for the claim (description of defect).

7.1.3 Please follow the applicable waste management laws when disposing of packaging.

Pb

Fai una domanda su AEG LP 10.0 - 97100

I possessori del prodotto e il nostro team di solito rispondono entro 24 ore, e la tua domanda sarà utile anche ad altri.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Nessuna domanda ancora per il dispositivo AEG LP 10.0 - 97100

Invia la prima domanda: risponderanno altri possessori o il nostro team.

Documento originale

AEG LP 10.0 - 97100 manuale in PDF

98 pagine·4.3 MB·Caricabatterie·PDF
Clicca su qualsiasi pagina in alto per aprirla qui
Pagina 1 / …
100%
Caricamento pagine…