Manuale d’uso / di manutenzione del prodotto M7VIG400 del fabbricante Biostar
Vai alla pagina of 28
M M M 7 7 7 V V V I I I G G G 4 4 4 0 0 0 0 0 0 FCC Information and Copyright This equ ipment has been tested an d found to comply w ith the limits of a Class B dig ital de vice, pursuant t o Part 15 of the FCC Rules. The se li mits are designed to pr ovide reasonable pro tection against harmfu l interfer ence in a residen tial in stalla tion.
C C C o o o n n n t t t e e e n n n t t t s s s LA YOUT OF M7VI G 4 00 ......................................................................... 1 COMPONENT INDEX ............................................................................. 2 M7VIG 400 SYSTEM STRUCTURE .
M M M 7 7 7 V V V I I I G G G 4 4 4 0 0 0 0 0 0 Layout of M7VI G 400 NOTE: ● represents the fir st pin. 1.
M M M 7 7 7 V V V I I I G G G 4 4 4 0 0 0 0 0 0 Components Index A . Back Panel Connectors K. Fl oppy Disk Connector (FDD1) B. CPU Fan Connector (JCFAN1) L. Case Open Connector (JCI1)* C. A TX Power Connector ( JAT XPWER1) M. Front Panel C onnector (JPA N EL1) D.
M M M 7 7 7 V V V I I I G G G 4 4 4 0 0 0 0 0 0 M7VIG 400 System Structure 3.
M M M 7 7 7 V V V I I I G G G 4 4 4 0 0 0 0 0 0 English M7VIG 400 Fea tures A. Hardw are CPU Provides Soc ket A. Supports single AM D ® Athlon X P/ Duron Family processor. Front Side Bus at 20 0/266/33 3 M Hz. Chipset North Bridge: VIA KM 266 Pro. South Bridge: VIA VT8235.
M M M 7 7 7 V V V I I I G G G 4 4 4 0 0 0 0 0 0 On Board Peripherals a. Rear si de 1 serial port. 1 VGA port. 1 parallel por t. (SPP/EPP/ECP mode) Audio ports in vertical pos ition. 1 RJ-45 LAN jack . PS/2 mouse and PS/2 keyboa rd. 4 USB2.0 ports. b. Front Side 1 floppy port sup ports 2 FDD s w ith 360K, 720K, 1.
M M M 7 7 7 V V V I I I G G G 4 4 4 0 0 0 0 0 0 How to set up Jumper The illust ration show s how to set up a ju mper. When the Jum per cap is plac ed on pins, t he jumper is “ close”. If no j umper cap is pl aced on t he pins, the ju mper is ”open”.
M M M 7 7 7 V V V I I I G G G 4 4 4 0 0 0 0 0 0 CPU Fan Header: JC FAN1 Pin Assignment 1 Ground 2 +12V 1 JCFAN 1 3 FAN RPM rate Sense System Fan Header: JSFAN1 Pin Assignment 1 Ground 2 +12V 1 JSFAN1 .
M M M 7 7 7 V V V I I I G G G 4 4 4 0 0 0 0 0 0 Installing DDR Module 1. U nlock a DIM M slot by pres sing the re taining clips outward. Alig n a DIMM to the slot in the w ay that the notch of the DIM M matc hes t he break of the slot.
M M M 7 7 7 V V V I I I G G G 4 4 4 0 0 0 0 0 0 JCI1 2 Ground Front Panel Connector: JPANEL1 SP K PW R _ LE D HL E D SL P RS T 2 24 IR 1 23 IR ON/ O F F (+ ) (- ) (+ ) (- ) (+ ) Pin Assignment Functio.
M M M 7 7 7 V V V I I I G G G 4 4 4 0 0 0 0 0 0 JATXPWER1 10 +12V 20 +5V Clear CMOS Ju mper: JCMOS 1 JCMOS1 A ssignment 1 Pin 1-2 Close Normal Operati on (defa ult) 1 Pin 2-3 Close Clear CMOS Data ※ Clear CMOS Procedures: 1. Remove AC power lin e. 2.
M M M 7 7 7 V V V I I I G G G 4 4 4 0 0 0 0 0 0 7-8 Open Open Open Front Panel Audio Header: J F_AUDIO1 1 2 13 14 JF _AUDIO 1 Pin A ssignment Pin Assignment 1 Mic In/ Center 2 Ground 3 Mic P ower / Ba.
M M M 7 7 7 V V V I I I G G G 4 4 4 0 0 0 0 0 0 6 C h a n n e l S p e a k e r s Speaker Out/ Fron t Speaker (Rig ht & Lef t) Line In/ Rear Speaker (L eft & Right ) Mic In / Ce nt er & Bas .
M M M 7 7 7 V V V I I I G G G 4 4 4 0 0 0 0 0 0 Français Caractéristiques de M7VIG 400 A. Matériel Processeur Avec so cket A. Prise en charge du processeu r AMD ® Athlon X P/Duron F amily. Bus frontal à 200/2 66/333 M Hz. Jeu de puces North Bridge : VIA KM 266 Pro.
M M M 7 7 7 V V V I I I G G G 4 4 4 0 0 0 0 0 0 Puce: CMI 9761A Conforme aux spécificat ions AC ’97. Interface AC’97 2 .3. Prise en charge de 6 canaux. Prise en charge de la microphone stere o. Périphériques int égrés a. Côté arrièr e 1 port sér ie.
M M M 7 7 7 V V V I I I G G G 4 4 4 0 0 0 0 0 0 WarpSpeed er™ Introduction [ WarpSpeeder™ ], a new po werful contr ol utility , features three user-frien dly functi ons , AGP and PCI uter a nd then r estart to a speed th at is either e origin al syste m speed or a suitable one.
M M M 7 7 7 V V V I I I G G G 4 4 4 0 0 0 0 0 0 Installation 1. Execute the setup execution file, and then the fol lowing d ialog w ill pop u p. Please clic k “Next” butto n and follow the default proc edure to inst all. 2. W hen you see the fol lowing dialog in s etup pro cedure, it means setup is completed.
M M M 7 7 7 V V V I I I G G G 4 4 4 0 0 0 0 0 0 Usage The foll owing figures are just only for refere nce, the s creen pr int ed in t his us er m anual w ill change accord ing to y our m otherboar d on hand . [ W arpSpeeder™ ] include s 1 tray icon and 5 p anels: 1.
M M M 7 7 7 V V V I I I G G G 4 4 4 0 0 0 0 0 0 This utility is res ponsible for convenie ntly invok ing [ W arpS peeder™] Ut ility. Y ou can use the mouse by clicking t he left button in order to i.
M M M 7 7 7 V V V I I I G G G 4 4 4 0 0 0 0 0 0 3. Volta ge Panel Click the Vo ltage button in M ain Pan el, the button w ill be high lighted a nd the Voltage Panel will slide out t o up as the follow ing figure. In this panel, y ou can dec ide to increa se CPU core v oltage and Memory voltage or not.
M M M 7 7 7 V V V I I I G G G 4 4 4 0 0 0 0 0 0 4. Overc lock Panel Click the Overclo ck button in M ain Panel, the bu tton will be highligh ted and t he Overcloc k Panel will slide out t o left a s the follow ing figure.
M M M 7 7 7 V V V I I I G G G 4 4 4 0 0 0 0 0 0 Overclock Panel contains the these features: a. “–3M Hz button”, “-1M Hz button”, “+1M Hz button”, and “ +3M Hz button”: provi de user the ability to do rea l-time over clock adjus tment.
M M M 7 7 7 V V V I I I G G G 4 4 4 0 0 0 0 0 0 d. “Auto-overcloc k button”: User can cli ck th is button a nd [ WarpSpeeder™ ] w ill set the best and st able perf ormance and freq uency auto matically. [ WarpSpeeder™ ] utility w ill ex ecute a serie s of testing un til syste m fail.
M M M 7 7 7 V V V I I I G G G 4 4 4 0 0 0 0 0 0 5. Hardw are Monitor Panel Click t he Hardw are Monitor button in M ain Panel, th e button w ill be highli ghted and the Hardware M onitor panel w ill sli de out to left as the f ollow ing figure. In this panel, y ou can get the r eal-time statu s informatio n of your sy stem.
M M M 7 7 7 V V V I I I G G G 4 4 4 0 0 0 0 0 0 Note: Beca use the overc lock, overvoltag e, and har dware m onitor f eatures are control led by s everal separ ate chips et, [ W arpSpeeder™ ] divide thes e features to separ ate pa nels.
M M M 7 7 7 V V V I I I G G G 4 4 4 0 0 0 0 0 0 Trouble Shooting PROBA BLE SOLU TION No po wer to t he s ystem at all P owe r light don’t illuminate, fan inside power s uppl y does not t urn on.
M M M 7 7 7 V V V I I I G G G 4 4 4 0 0 0 0 0 0 26 3/26/200 4.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Biostar M7VIG400 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Biostar M7VIG400 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Biostar M7VIG400 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Biostar M7VIG400 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Biostar M7VIG400, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Biostar M7VIG400.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Biostar M7VIG400. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Biostar M7VIG400 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.