Manuale d’uso / di manutenzione del prodotto R2W-6500P del fabbricante Zippy
Vai alla pagina of 15
PRODUCTS MANUAL R2W SERIES High Density Redundant Power Supply For 2U Chassis Rev .:A1 P/N:702-10041.
I N D E X 1.1 Introduction page 2 1.2 Packing page 3 1.3 Model Designation page 3 1.4 Features page 4 1.5 Pre-Installation page 4 1.6 Drawing page 5 ~ 6 1.7 Specification page 7 ~ 9 1.8 Installation & T esting page 10 ~ 1 1 1.9 Hot-Swap Procedures page 1 1 ~ 12 1.
1.1 INTRODUCTION First of all, thank you for purchasing R2W Series – High-Density Redundant power supply for 2U chassis. The R2W is a 1+1, Hot-swappable/Hot-pluggable, High-Density Redundant power s.
1.2 P ACKING Y our R2W box package should consist of the following: (A) R2W *1 (B) Accessory pack (included 1 holding bracket for shipment)*1 (C) Products’ manual *1 1.3 MODEL DESIGNA TION Model number identification: R2W – 6ZZZP R --- Redundant (AC Input) 2W --- suit for 2U chassis (1U = 44.
1.4 FEA TURES R2W Series --- High-Density Redundant power supply with Active Power Factor c o r r e c t i o n 1+1, Hot swappable, Hot pluggabl e, AC Input for 2U chassis Easy fit into 2U , 400/460W +4.
.
.
INPUT CHARACTERISTICS: R2W-6400P VOLTAGE: 90 ~ 264 VAC FULL RANGE FREQUENCY : 47 ~ 63 Hz INPUT CURRENT: 8.0 / 4.0 A FOR 115 / 230 VAC INRUSH CURRENT: 60A / 80A MAX. FOR 115 / 230 VAC PER POWER MODULE OUTPUT CHARACTERISTICS: OUTPUT CURRENT REGULATION OUTPUT MIN.
INPUT CHARACTERISTICS: R2W-6460P VOLTAGE: 90 ~ 264 VAC FULL RANGE FREQUENCY : 47 ~ 63 Hz INPUT CURRENT: 8.0 / 4.0 A FOR 115 / 230 VAC INRUSH CURRENT: 60A / 80A MAX. FOR 115 / 230 VAC PER POWER MODULE OUTPUT CHARACTERISTICS: OUTPUT CURRENT REGULATION OUTPUT MIN.
INPUT CHARACTERISTICS: R2W-6500P VOLTAGE: 105 ~ 264 VAC FULL RANGE FREQUENCY : 47 ~ 63 Hz INPUT CURRENT: 8.0 / 4.0 A FOR 115 / 230 VAC INRUSH CURRENT: 60A / 80A MAX. FOR 115 / 230 VAC PER POWER MODULE OUTPUT CHARACTERISTICS: OUTPUT CURRENT REGULATION OUTPUT MIN.
1.8 INST ALLA TION & TESTING T urn of f (Remote off) the on/of f switch. Mount the power supply in the system chassis using the proper mounting tool, the mounting holes in the power supply should match those in the case.
If everything works out fine, then turn off (rem ote off) the power system. Now put back the cover of the case and tighten with the screws that you have retained earlier . Now you have completed the in stallation of the R2W redundant power supply system.
D) Replace a new Good power module, insert the power module into the power system to the end. E) Check the LED of the power module light Green. F) Check the LED indicating the total power system status. It should be from twinkle to Green. G) T ighten the screws of the power module to fix it.
TTL signal : S i n k c u r r e n t m a x . 5 m A S o u r c e c u r r e n t m a x . 5 0 u A Low Active --- Defective High --- Normal 1.11 TROUBLE SHOOTING If you have followed these directions correctly , there should be no problem occurred. Some comm on symptoms are: the system doesn’ t work, buzzer sounds, work for a very short period, etc.
The “RELIABILITY “ solution to E-application 新巨企業股份有限公司 ZIPPY TECHNOLOGY CORP . POWER DIVISION HEADQUAR TERS 10F , NO. 50, MIN CHYUAN RD., SHIN-TIEN CITY , T AIPEI HSIEN, T AIW AN, R.O.C. TEL: 886-2-29188512 F AX: 886-2-29134969 WEB SITE: http://www .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Zippy R2W-6500P è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Zippy R2W-6500P - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Zippy R2W-6500P imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Zippy R2W-6500P ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Zippy R2W-6500P, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Zippy R2W-6500P.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Zippy R2W-6500P. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Zippy R2W-6500P insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.