Manuale d’uso / di manutenzione del prodotto AK6000 del fabbricante Zephyr
Vai alla pagina of 21
2EADALL)NSTRUCTIONSBEFORE)NSTALLINGANDOPERATINGTHISAPPLIANCE -/$%, AK2000,AK6000,AK9800 )MPORTANT3AFETY.OTICE 5SE#AREAND)NSTALLATION'UIDE : $51,1* 725('8&(7+(5,6.
)MPORTANT3AFETY.OTICE 2EADANDSAVETHESEINSTRUCTIONS G 8VHDQH[WLQJXLVKHU21/ <LI < RXNQRZRXKDYHD&ODVV$%.
PRODUCT OVERVIEW WHIRLWIND SERIES HURRICANE SERIES CYCLONE SERIES 1 Model number: AK2000, 2036 QuattroVent Air Curtain Dual “Thrust-Fore" Self Clean Blowers Digital Touch Pad Controls Clock, Timer, 3 stage Delay Shutoff. Model number: AK9 8 00 Dual Self Clean Blowers Independent Rocker Controls w/ High, Low speed Slim Line Design Overview 1.
CONTROLS HURRICANE SERIES 2 Controls Overview 1. Set Time 2. Digital Display 3. Set Hours 4. Set Minutes 5. Set Timed Delay Shut Off 6. Light On-Off 7. Left Blower: On-High-Low-Off 8. Right Blower: On-High-Low-Off 9. Operations: On-Off 10. Right Blower Low Speed Indicator 11.
Blower Controls You can simultaneously turn On the light and both blowers on Hi speed by simply pressing "On/Off" once. During this time, you can select blowers and speed as indicated by pressing the "Fan-L" and "Fan-R" button.
CONTROLS 4 Setting Timer (Alarm) Press " hr " and " min " button to set desired timer countdown. Once timer is set, countdown will start in 7 seconds as delay indicator light flashes. When countdown reaches 0, 10 short beeps will sound.
MAINTENANCE 5 Self Clean Feature All Zephyr Range Hoods are filter-less and are designed with a self clean feature. The centrifugal blower system automatically liquefies grease accumulated in its internal housing. All systems are equipped with dishwasher safe grease containers for its self clean function.
Hurricane Series: Remove light shield by turning counter- clockwise. Clean in dishwasher under normal wash cycle. Whirlwind Series: Remove light shield by unscrewing Philips screw. Clean in dishwasher under normal wash cycle. Cleaning Tip: Fill residue containers ¼ full with water before cleaning or during regular use.
MAINTENANCE 7 QuattroVent Channels The QuattroVent Air-Curtain channels are adjoined to its two main blowers and share the same internal housing. No further cleaning is required after the self clean is completed. Clean residue around the channels surface with ‘409’ and a cotton cloth regularly.
INST ALLA TION 8 REQUIREMENTS ACCESSORIES WARNING Installation of this product is intended for qualified installers, service technicians, or persons with similar qualified background.
INST ALLA TION 9 MIN. 18” MAX 30” net width DUCT OPENING CLEARANCES Front Rear Front Rear Wall Minimum clearance above range should be no less than 18“ from the range surface to the range hood’s base. Maximum height are recommended not to exceed 30” for maximum efficiency.
INST ALLA TION 10 STEP 1 STEP 3 STEP 5 STEP 2 STEP 4 STEP 6 (also refer notes on pg. 16) 1. Remove all contents from box 2. Unscrew and remove bottom grease splash shield 1. Locate electrical connection box knock out from left rear of hood and pry open with screwdriver 1.
INST ALLA TION 11 STEP 7 STEP 9 (also refer notes on pg. 16) STEP 11 STEP 8 STEP 10 STEP 12 (also refer notes pg. 16) 1. Lift hood to bottom of cabinet 1. Support hood to place, fasten both rear with screws and washers provided. 1. Fasten front of hood.
INST ALLA TION 12 STEP 13 STEP 15 STEP 17 STEP 14 STEP 16 STEP 18 1. On Cyclone & Whirlwind models, be sure to pull both grease tubes over its opening. 1. Turn on electrical supply or plug into receptacles. 1. Reinstall electrical box cover. 1. Next, fasten the 3 front screws and begin tightening all screws from rear to front.
INST ALLA TION 13 CONVERTIBLE OPTIONS 3-1/4 x 10“ Vertical Discharge 1. Remove pre-mounted 6“ transition adaptor on duct opening. Leave attached gasket in its original place. 3. Mount the 3-1/4 x 10“ starting collar on top of transition piece with remaining screws.
INST ALLA TION 14 3-1/4 x 10“ Rear Discharge 4. At rear of range hood, remove all screws on pre- mounted rear rectangular cap and remove cap with gasket. 6. Remove 2 arch blocks through top opening. Option 1: (for recessed cabinet base) Re-install originally pre-mounted round transition piece at opening with gasket.
INST ALLA TION 15 3-1/4 x 10“ Rear Discharge Option 2: (for flush cabinet base) Mount rectangular transition piece at opening with gasket as shown. Mount rectangular cap (previously removed) on top of transition adaptor.
INST ALLA TION 16 INSTALLA TION NOTES Step 6: A damper (not included) should be installed to prevent back-draft where needed. A damper might also be required local codes in order to qualify for building inspections. You can purchase dampers from most hardware stores, or call our service line to order.
TROUBLE SHOOTING 17 1. Upon completion of installation, nothing works. 2. Light is on but blowers are not turning at all or seems to be scraping on something. 3. When blowers are on, something seems to be loose and spinning around inside. 4. Vibration when blowers are on 5.
TROUBLE SHOOTING 18 11. Cooking fumes and smoke dissipates before it reaches the blower. Use a damper type sidewall cap. Reduce the number of elbows and length of duct work. Check if all joints are properly connected, sealed and taped. Check if unit is installed at the recommended height (page 9).
www.zephyronline.com Warranty One Y ear Service Repair W arranty: F or one year from date of original purchase, we will provide free of c harge, service lab or to repair any failed parts or components due to manufacturing defects.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Zephyr AK6000 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Zephyr AK6000 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Zephyr AK6000 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Zephyr AK6000 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Zephyr AK6000, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Zephyr AK6000.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Zephyr AK6000. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Zephyr AK6000 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.