IT
Zanussi logo
Manuale d'uso ufficiale

Zanussi BC180A

5 pagine·186 KB·Frigorifero·PDF·EN
Zanussi BC180A
Indice dei contenuti 4 sezioni RANGE COMPOSITION · FUNCTIONAL AND CONSTRUCTION FEATURES · ‹ Holding at +3°C (automatically · ‹ Door equipped with removable magnetic gasket with hygienic MostraNascondi
Page 1 of the Zanussi BC180A user manual — ‹ Holding at +3°C (automatically
Pagina 1 · clicca per ingrandire
Pagina 1
Zanussi BC180A — RANGE COMPOSITION diagram (page 1)
Fig. 1

RANGE COMPOSITION

Chilling means bringing the temperature of cooked food from +90ºC to +3°C in a short time lap to minimize bacteria proliferation and avoid loss of food consistency and texture. The ZANUSSI easyChill Blast Chillers reduce temperature to +3°C at food core in less than 90 minutes. After the Blast Chilling a holding cycle starts automatically to maintain food at +3°C. Blast chilled food has a solid 5 days shelf life without loss of flavour, nutritional values and weight. The opportunity to prepare in a single shot the food to be used in different times during the week enables a better work scheduling and therefore a sensible reduction in labour costs.

ZANUSSI P R O F E S S I O N A L ACTIVE BLAST CHILLERS

FUNCTIONAL AND CONSTRUCTION FEATURES

‹ All the probe-driven cycles feature ARTE (Algorithm for Remaining Time Estimation): the machine displays the actual time needed to end the cycle and to make planning the activities easier.

activated at the end of each cycle).

‹ Turbo cooling: the chiller works continuously at the desired temperature. Ideal for continuous production and for pastry application.

‹ Soft Chilling (Air temperature –2°C).

‹ Hard Chilling (Air temperature –12°C).

‹ Holding at +3°C (automatically

TECHNICAL DATA CHARACTERISTICSMODELS BC120A 110089BC120RA 110090BC180A 110005BC180RA 110007BC180RPA 110009BC180RDA 110008BC180DA 110006 Productivity per cycle - kg. NF Regulations - chilling / freezing144144144144144 UK Guide lines - chilling / freezing120120180180180180180 Cooling unitBuilt-InRemoteBuilt-InRemoteRemoteRemoteBuilt-In External dimensions - mm width1400140014001400140014001400 depth/with open doors1285, 20991285, 2099 height2470247024712230223022302471 Internal dimensions - mm width772772752752752752752 depth920920946946946946946 height1850185018501850185018501850 N° and type of door111;1;2;1;1; Door hingesRight SideRight Side Trays type600x400; GN 2/1600x400; GN 2/1600x400; GN 2/1600x400; GN 2/1600x400; GN 2/1600x400; GN 2/1600x400; GN 2/1 Max load capacity - trays h 65 mm - n°20202020 Compressor power - HP47.5minimum 7,5;7,5; N° defrost in 24 hrs.4/20'4/20'4/20'4/20'4/20'4/20'4/20' Refrigerant typeR404aR404aR404a;R404a;R404a;R404a;R404a; Refrigeration power - W111002020020200202002020020200 Refrigerant power at evaporation temperature - °C-10-10-10-10-10-10 Power - kW installed-electric6.5151.838.331.7351.7351.7358.335 Net weight - kg.300180605438438180605 Power supply - V, phases, Hz400 V, 3N, 50400 V, 3N, 50400 V, 3N, 50400 V, 3N, 50400 V, 3N, 50400 V, 3N, 50400 V, 3N, 50 Disassembledll INCLUDED ACCESSORIES 1 SINGLE SENSOR PROBE CHILLER+C/FREEZER1111111
Page 2 of the Zanussi BC180A user manual — ‹ Door equipped with removable magnetic gasket with hygienic
Pagina 2 · clicca per ingrandire
Pagina 2

‹ Single sensor core probe as standard.

programs (P1-P2) can be converted into ice-cream specialist cycles (shape maintenance and holding).

design.

‹ Evaporator with antirust protection.

‹ Automatic recognition of the insertion of the food probe (cycles piloted either by food probe temperature or by time)

‹ All information related to the different operating models are recorded: date, time, cycle, core temperature, holding temperature, HACCP accordance.

‹ Ventilator swinging panel foreasy access to the evaporator.

‹ Automatic heated door frame.

‹ The control unit provides several operating settings: time/core temperature according to NF and UK regulations, time/air temperature/probe personalised according to national regulations, sterilizing cycle: UV lamps built-in (on request), 3 single sensor or 3-sensor temperature probes (as accessory), ideal for meats, automatic defrosting and manual defrosting. All parameters are programmable.

‹ Thermostatic expansion valve to optimize the cooling unit efficiency.

‹ An audible alarm starts when the cycle ends or terminates abnormally.

‹ Adjustable feet 150 mm high.

‹ Stand alone printer as accessory.

‹ Chilling times can vary according to food quantity, density, moisture contents and type of containers.

‹ PC connection as accessory, gate RS 485.

‹ No water connections required: Waste water can be plumbed into drain, but can also be collected in an optional waste container.

‹ Internal and external finishing in 304 AISI stainless steel and backpanel in galvanized steel.

‹ HCFC, CFC and HFC free insulation (Cyclopentane), HCFC and CFC free refrigerant gas (R404a).

*NF HYGIENE ALIMENTAIRE certifying authority: AFAQ AFNOR CERTIFICATION. Adress:11, Avenue Francis de Pressense - 93571 Saint-Denis La Plaine Cedex - France. Conformity with regulation NF031. Certified guarantees: fitness for cleaning, thermal performance.

‹ The control unit provides two large displays to read out: time, core temperature, residual time, alarms, service information.

‹ Developed and produced in ISO 9001 and ISO 14001 certified factory.

‹ Two customizable cycles for each operating modes, allowing setting time and air temperature. These two

‹ Inner cell with rounded corners.

‹ Door equipped with removable magnetic gasket with hygienic

OPTIONAL ACCESSORIES ACCESSORIESMODELS BC120A 110089BC120RA 110090BC180A 110005BC180RA 110007BC180RPA 110009BC180RDA 110008BC180DA 110006 1 SINGLE SENSOR PROBE CHILLER+C/FREEZER880089880089880089880089880089880089880089 2 SINGLE SENSOR PROBES CHILLER+C/FREEZER880096880096880096880096880096880096880096 3-SENSOR PROBE FOR CHILLER+C/FREEZER880088880088880088880088880088880088880088 60 MM PITCH ROLL-IN RACK FOR 20X2/1922204922204922204922204922204922204 80MM PITCH ROLL-IN RACK 14X2/1GN922206922206922206922206922206922206 AIR REMOTE UNIT CHILLER+C/FREEZER180KG880051880051880051880051 BANQ.TROLLEY-92PLATES 85MM PITCH-20GN2/1922055922055922055922055922055922055922055 BASE FOR 20X2/1 ROLL-IN RACK922142922142922142922142922142922142922142 BASE FOR ROLL-IN-RACK880018880018880018880018880018880018 KIT 3 SINGLE SENSOR PROBES FOR BC/BCF880269880269880269880269880269880269880269 KIT HACCP ADVANCED CONNECT. BC/BCF LW+CW880183880183880183880183880183880183880183 KIT HACCP EKIS922166922166922166922166922166922166922166 PASTRY TROLLEY 16(400X600)80MM-20 2/1 LW922069922069922069922069922069922069922069 PRINTER FOR HACCP BASIC VERSION881532881532881532881532881532881532881532 ROLL-IN RACK FOR 2/1 GASTRONORM GRIDS881449881449881449881449881449881449881449 THERMAL COVER FOR 20 GN 2/1-LW922049922049922049922049922049922049922049 TROLLEY FOR 2/1-GN ROLL-IN RACK880017880017880017880017880017880017880017 TROLLEY FOR 20X2/1 ROLL-IN RACK922134922134922134922134922134922134922134 TROLLEY TRAY RACK F. 20X2/1GN,63MM PITCH922044922044922044922044922044922044922044 TROLLEY TRAY RACK F. 20X2/1GN,80MM PITCH922046922046922046922046922046922046922046 WATER REMOTE UNIT CHILLER+C/FREEZER180KG880052880052880052880052

DCA05 2009-07-03 The Company reserves the right to alter technical specifications without prior notice.

Page 3 of the Zanussi BC180A user manual — ‹ Door equipped with removable magnetic gasket with hygienic
Pagina 3 · clicca per ingrandire
Pagina 3
Zanussi BC180A — ‹ Door equipped with removable magnetic gasket with hygienic diagram (page 3)
Fig. 2 · ‹ Door equipped with removable magnetic gasket with…
LEGEND BC120A 110089BC180A 110005BC180DA 110006 CWI - Cold water inlet1"1" D - Water drain3/4"3/4" EI - Electrical connection400 V, 3N, 50400 V, 3N, 50400 V, 3N, 50 Q - Appliance lifting connectionll WOC - Cooling water outletlll

ZANUSSI P R O F E S S I O N A L

DCA05 2009-07-03 The Company reserves the right to alter technical specifications without prior notice.

Page 4 of the Zanussi BC180A user manual — ‹ Door equipped with removable magnetic gasket with hygienic
Pagina 4 · clicca per ingrandire
Pagina 4
Zanussi BC180A — ‹ Door equipped with removable magnetic gasket with hygienic diagram (page 4)
Fig. 3 · ‹ Door equipped with removable magnetic gasket with…
LEGEND BC120RA 110090BC180RA 110007BC180RDA 110008 D - Water drain3/4"3/4" ED - Remote electrical connectionlll EI - Electrical connection400 V, 3N, 50400 V, 3N, 50400 V, 3N, 50 Q - Appliance lifting connectionll RI - Remote refrigeration connectionlll

ZANUSSI P R O F E S S I O N A L

DCA05 2009-07-03 The Company reserves the right to alter technical specifications without prior notice.

Page 5 of the Zanussi BC180A user manual — ‹ Door equipped with removable magnetic gasket with hygienic
Pagina 5 · clicca per ingrandire
Pagina 5
Zanussi BC180A — ‹ Door equipped with removable magnetic gasket with hygienic diagram (page 5)
Fig. 4 · ‹ Door equipped with removable magnetic gasket with…
LEGEND BC180RPA 110009 D - Water drain3/4" ED - Remote electrical connectionl EI - Electrical connection400 V, 3N, 50 RI - Remote refrigeration connectionl

ZANUSSI P R O F E S S I O N A L

DCA05 2009-07-03 The Company reserves the right to alter technical specifications without prior notice.

Fai una domanda su Zanussi BC180A

I possessori del prodotto e il nostro team di solito rispondono entro 24 ore, e la tua domanda sarà utile anche ad altri.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Nessuna domanda ancora per il dispositivo Zanussi BC180A

Invia la prima domanda: risponderanno altri possessori o il nostro team.

Documento originale

Zanussi BC180A manuale in PDF

5 pagine·186 KB·Frigorifero·PDF
Clicca su qualsiasi pagina in alto per aprirla qui
Pagina 1 / …
100%
Caricamento pagine…