Manuale d’uso / di manutenzione del prodotto DEVON 50 del fabbricante Yeoman
Vai alla pagina of 39
PM302 Issue 4 (October 2010) High Output Boiler Stoves M ODELS : YEOMAN DEVON 50/COUNTY 60/COUNTY 80 Instructions for Use, Installation and Servicing For use in GB & IE (Great Britain and Republic of Ireland).
COVERING THE FOLLOWING MODELS: YEOMAN DEVON/COUNTY 60/COUNTY 80 2 APPLIANCE COMMISSIONING CHECKLIST 3 USER INSTRUCTIONS 4 General Points 4 Heating Controls 5 Using the Appliance for the first time 6 C.
3 APPLIANCE COMMISSIONING CHECKLIST To assist us in any guarantee claim please complete the following information. In the unlikely event of a problem, contact your installer or retailer for assistance: Retailer appliance was purchased from Name: .....
4 USER INSTRUCTIONS 1. GENERAL POINTS 1.1 Before use of this appliance please read these instructions fully. The appliance must be fitted by a registered installer * or approved by your local building control officer.
5 USER INSTRUCTIONS AIRWASH & PRIMARY AIR CONTROLS 1.14 Use a gloved hand to operate air controls. Primary Air Control PR7519 Airwash Control Airwash Control Open Close Primary Control Open Close Open DOOR HANDLE 1.15 Use a protected gloved hand to operate.
6 USER INSTRUCTIONS WARNING Properly installed, operated and maintained this appliance will not emit fumes into the room. Occasional fumes from de-ashing and refuelling may occur. Persistent fume emission is potentially dangerous and must not be tolerated.
7 USER INSTRUCTIONS 4 — Leave the door slightly open as the fire establishes and the glass warms to avoid the build-up of condensation. — Add larger pieces of solid fuel once the fire is established Do not add too much fuel initially as this may smother the fire.
8 USER INSTRUCTIONS 6 PR8855 7 PR7519 Primary Air: Fully Open Airwash: Fully Open — Wood burns best on a bed of ash (approx. 25mm (1") deep). — Rake the embers evenly over the firebed and open the Airwash control fully for a few minutes before re-fuelling.
9 THERMOSTAT OPERATION 5.17 This appliance can be fitted with a thermostat kit to control the temperature of the boiler. See the instructions included in the kit for operation details. 6. BURNING TIPS 6.1 Fuel Quality (Wood) Use wood with a moisture content of less than 20%.
9 PR8881 PR8880 Front plate Ashpan — Using gloves, carefully remove ashpan (see Diagram 9). — Place the ash into a Stovax Ash Caddy (Stovax Part No. 4227) or other suitable container. — Check and remove ash as often as required when burning solid fuel.
9. EXTENDED BURNING 9.1 It is possible to get the appliance to burn for extended periods. In order to do this: — De-ash prior to final refuelling. — Set air controls to low combustion settings. This will blacken the glass over night but it will clear when operated at high output for a short period.
13. CLEANING GLASS 13.1 Kee p th e gl as s cle an wit h co rr ec t use of th e Ai rw ash sys te m and goo d qu al it y fue l. Som et im es ad di ti on al clea ni ng may be req ui re d. This can be done as follows: — Allow appliance to cool fully. Do not clean hot glass.
16. SEASONAL USE 16.1 Clean and service the appliance if it is not used during the warmer periods of the year as detailed in the Maintenance and Servicing section. 16.2 Set the air controls 50% open to keep the appliance ventilated and stop the build-up of any moisture inside.
TECHNICAL SPECIFICATION YEOMAN 14 Model Yeoman Devon 50 Yeoman County 60 Yeoman County 80 Yeoman Devon 50 Yeoman County 60 Yeoman County 80 Nominal Heat Output to Room Solid Fuel kW 5.0 7.0 9.0 Nominal Heat Output to Water kW 8.0 11.0 14.0 Flue Draught at Nominal Heat Output All Fuels mm Wg 1.
2. PACKING LIST • User Instructions • Installer Instructions • Guarantee card • Pair leather gloves • Door handle tool • Fire bricks • Ashpan (MF Only) • Riddling tool (MF Only) TECHNICAL SPECIFICATION 1.
TECHNICAL SPECIFICATION YEOMAN DIMENSIONS Description Model A B C D E F G H I J K (dia) Devon 50 590 659 389 118 469 430 120 400 241 315 153 County 60 632 772 446 125 507 508 126 530 246 343 153 Count.
1. FLUE OR CHIMNEY 1.1 The flue or chimney system must be in good condition. It must be inspected by a competent person and passed for use with the appliance before installation. Products of combustion entering the room can cause serious health risks.
2.1 The appliance must stand on a constructional hearth which is at least 125mm thick with the minimum dimensions as shown in the diagram opposite. 2.2 The building must have a suitable load-bearing capacity for the hearth and appliance. — Consult a structural engineer for advice before proceeding.
SITE REQUIREMENTS WALLS NEXT TO A HEARTH Solid, non-combustible material e.g. masonry or concrete Thickness W C 150mm minimum 150mm minimum C H PR7204 Position of Appliance & Hearth in relation to.
PRE-INSTALLATION CHECKS 1. FLUES 20 Model Yeoman Devon 50 Yeoman County 60 Yeoman County 80 Yeoman Devon 50 Yeoman County 60 Yeoman County 80 Flue / Chimney Size Without Liner System (round) Diameter .
2.6 Extractor fans or cooker hoods must not be placed in the same room or space as this can cause the appliance to emit fumes into the room. 2.7 Increase air supply provisions where a room contains multiple appliances. 2.8 The need for additional ventilation may also be identified during the commissioning procedure and should be provided if needed.
LEGAL REQUIREMENTS Before installation and/or use of this appliance please read these instructions carefully to ensure that all requirements are fully understood. The appliance must be fitted by a registered installer * , or approved by your local building control officer.
INSTALLATION INSTRUCTIONS — Connect tee to the chimney using flue pipe. — Secure with self tapping screw. — Seal the connecting joints. Do not use a 90˚ elbow to make this connection. The Flue must be installed in accordance with manufacturers instructions.
24 INSTALLATION INSTRUCTIONS 2. REMOVAL OF THE LOG GUARD 2.1 To remove the Log guard: — Lift Log Guard clear of the supporting brackets. — Rotate to clear the sides of the door opening. Do not use appliance without the log guard in position. 3. FITTING AND REMOVAL OF THE BAFFLE No tools are required.
INSTALLATION INSTRUCTIONS 9 PR8896 5mm Hex Key Riddling Boss Fixing Bolt Spring Washer — Unscrew the boss. — Remove Riddling Cam Bar (see Diagram 10). 10 PR8889 To remove Multi-fuel frames: — Lift frames from the front. — Remove right hand side first through the front of the stove.
3. Hot Water Cylinder 3.1 The domestic hot water cylinder must be an indirect vented double feed type to meet national standards** and should have a minimum capacity of 117 litres. Houses with more than one bathroom or a separate shower will need a bigger tank.
INSTALLATION INSTRUCTIONS 27 6. Pump 6.1 Where a pump is fitted into the circuit it should be adjustable so that the flow can match the system requirements. Fit isolation valves to enable removal for servicing. The pump must have at least 1.5 meters of static head.
INSTALLATION INSTRUCTIONS 28 See below typical layout of a fully pumped central heating and hot water circuit. Feed and Expansion Cistern Cold Water Storage Cistern Double Feed indirect cylinder Circu.
HEATING SYSTEM CONTROLS CONTROLS GENERAL 1.1 The controls fitted to the system will provide two functions: — To control the comfort level in the house. — To maintain safety in the event of misuse or mechanical failure. COMFORT CONTROLS 1.2 This primarily consists of a time clock wired into the pump.
COMMISSIONING 1.1 To commission: — Replace the log retainer. — Check the door alignment and catch operation, adjust if required, see Installation Instructions, Section 6, Adjusting Door Hinges. — Check the soundness of door seals, castings and joints.
31 MAINTENANCE and SERVICING For a complete list of spare parts and accessories contact your Yeoman retailer or call 01392 474011 1. ANNUAL SERVICE 1.1 Before the start of the heating season strip, inspect and clean the appliance as detailed: — Allow appliance to cool.
5.4 Clean, and re-paint, the rear of the door if required. Clean the screws with light oil and coat with high temperature anti-seize grease, this will aid future removal. 5.5 Fit a new sealing rope between the new glass and the door, and place the glass into position in the door.
6.6 Using the stove with a damaged door seal could cause dangerous fumes to enter the room, or the stove to over- fire, resulting in damage. 6.7 If you require help, your local Yeoman retailer will be able to carry out all of your service and maintenance requirements for a reasonable cost.
SPARE PARTS DEVON 50 Re f. No. Product Code Drawing No . (if different) Description 1 ST8-MEC8158 MEC8158 RIDDLING T OOL ASSEMBL Y 2 YF00106 HINGE PIN 3 - YM-Y A2DDEVWD DEVON TWIN DOOR ASSEMBL Y 4 RVP.
SPARE PARTS COUNTY 60 Re f. No. Product Code Drawing No . (if different) Description 1 ST8-MEC8158 MEC8158 RIDDLING T OOL ASSEMBLY 2 YF00106 HINGE PIN 3 - YM-Y A2DCOUWD 2 DOOR ASSEMBL Y 4 RVPX-CA7588 .
SPARE PARTS COUNTY 80 Re f. No. Product Code Drawing No . (if different) Description 1 ST8-MEC8158 MEC8158 RIDDLING T OOL ASSEMBLY 2 - YM-Y A2DC14WD DOOR ASSEMBL Y 3 YF00106 HINGE PIN 4 RVPX-CA7588 CA.
SPARE PARTS DOOR ASSEMBLY (ALL MODELS) Re f. No. Product Code Drawing No . (if different) Description 1 SM29 M0508PHS M5 X 8 PAN HEAD SCREW 2 4670H Ø14 ROPE SEAL (BLACK) 3 YC00353 ST ANDARD GLASS CLI.
SERVICE RECORDS 38 1ST SERVICE Date of Service:........................................................................... Next Service Due:....................................................................... Signed:................................
Stovax Ltd, Falcon Road, Sowton Industrial Estate, Exeter, Devon, England EX2 7LF Tel: (01392) 474011 Fax: (01392) 219932 E-mail: info@stovax.com www.stovax.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Yeoman DEVON 50 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Yeoman DEVON 50 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Yeoman DEVON 50 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Yeoman DEVON 50 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Yeoman DEVON 50, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Yeoman DEVON 50.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Yeoman DEVON 50. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Yeoman DEVON 50 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.