Operating Manual XFR 2800 Watt Series Programmable DC Power Supply XFR 7.5-300 XFR 12-220 XFR 20-130 XFR 33-85 XFR 40-70 XFR 60-46 XFR 100-28 XFR 150-18 XFR 300-9 XFR 600-4.
.
Operating Manual for XFR 2800 Watt Series Programmable DC Power Supply.
ii Operating Manual for XFR 2.8kW Series Power Supply Limited W arranty What does this warranty cover and how long does it last? This Limited W arranty is provid ed by Xantrex T echnology , Inc. (“Xantrex”) and covers defects in workmanship and materials in your XFR 2800 W att Series DC Power Supply .
Release 2.1 iii Direct returns may be performed accordi ng to the Xantrex Return Material Authorization Policy described in your pr oduct manu al. For some products, Xantrex maintains a network of regional Authorized Service Centers. Call Xantrex or check our website to see if your product can be repaired at one of these facilities.
iv Operating Manual for XFR 2.8kW Series Power Supply Disclaimer Product THIS LIMITED W ARRANTY IS THE SOLE AND EXCLUSIVE W ARRANTY PROVIDED BY XANTREX IN CONNECTION WITH YO UR XANTREX PRODUCT AND IS,.
Release 2.1 v Information WITHOUT LIMITING THE GENERALITY OF THE FOREGOING, UNLESS SPECIFICALL Y AGREED TO BY IT IN WRITING, XANTREX a. MAKES NO W ARRANTY AS TO THE ACCU RACY , SUFFICIENCY OR SUIT ABILITY OF ANY TECHNICAL OR O THER INFORMA TION PROVIDED IN MANUALS OR OT HER DOCUMENT A TION PROVIDED BY IT IN CONNECTION WITH THE PRODUCT ; AND b.
vi Operating Manual for XFR 2.8kW Series Power Supply W arnings and Cautions W arnings and cautions are defined and fo rmatted in this manual as shown below . Power Supply Safety W ARNING Describes a potential hazard which could result in injury or death, or , a procedure which, if not performed correctly , could result in injury or death.
Release 2.1 vii About This Manual This Operating Manual contains user information for the XFR Series of variable DC output power supp lies, available in several voltage mode ls at 2800 W atts.
About This Manu al viii Operating Manual for XFR 2.8kW Series Power Supply Power Supply Safety Markings Alternating Current Off (Supply) Earth (Ground) T ermin al Caution (Hot Surface) Protective Conductor T erminal Caution (Check manual for additional info rmation.
Release 2.1 ix Content s About This Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii List of Figures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
x Operating Manual for XFR 2.8kW Series Power Supply Connecting Single Loads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 Connecting Multiple Loads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Release 2.1 xi List of Figures Figure 1.1 Power Supply Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Figure 1.2 Power Supply Rear Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Figure 1.
List of Figures xii Operating Manual for XFR 2.8kW Series Power Supply.
Release 2.1 xiii List of Tables Table 1.1 Available Voltage and Current Ranges . . . . . . . . . . . . . . . . . . . . . . . . 15 Table 1.2 Rear Panel SW1 Switch Assignments . . . . . . . . . . . . . . . . . . . . . . . . . 21 Table 1.3 Rear Panel J2 Connector Terminals and Functions .
List of T ables xiv Operating Manual for XFR 2.8kW Series Power Supply.
Release 2.1 15 Section 1. Features and S pecifications Description This series of power supplies provides low noise, precisely regulated, variable DC output at 2800 watts of output powe r . Over voltage protection (OVP) and thermal shutdown are standard.
Features and Specifications Features and Options 16 Operating Manual for XFR 2.8kW Series Power Supply • Front panel push-button c ontrol of output standb y mode and preview of v oltage, current, or over voltage protection setpo ints.
Features and Specifications Front Panel Controls Release 2.1 17 Front Panel Controls See Figure 1.1 to review the co ntrols, LEDs, and meters located on the power supply’ s front pane l. Check the following sections for additional descrip tions of front panel controls and functio ns.
Features and Specifications Rear Panel Connectors and Switch 18 Operating Manual for XFR 2.8kW Series Power Supply Rear Panel Connectors and Switch Use the rear panel SW1 Programming, Monit oring, and.
Features and Specifications Rear Panel Connectors and Switch Release 2.1 19 Figure 1.2 Power Supply Rear Panel (Low voltage (7.5 V to 100 V) model shown.) Blank Subplate (Replaced if digit al programming interface install ed.) SW1 Switch (See page 20 fo r more information.
Features and Specifications Rear Panel Connectors and Switch 20 Operating Manual for XFR 2.8kW Series Power Supply Rear Panel SW1 Switch The SW1 Programming, Monito ring, and Shutdown Select switch is an 8-position piano DIP switch located on the power supply’ s rear panel.
Features and Specifications Rear Panel Connectors and Switch Release 2.1 21 T able 1.2 Rear Panel SW1 Switch Assignments Resetting the Switches Before making any chang es to the switch settings, disable the power supply output by push ing the front panel ST ANDBY switch to its IN position.
Features and Specifications Rear Panel Connectors and Switch 22 Operating Manual for XFR 2.8kW Series Power Supply Rear Panel J2 Connector The J2 Programming and Mo nitoring connector is a 15-terminal wire clamp connector located on the power supply’ s rear panel.
Features and Specifications Rear Panel Connectors and Switch Release 2.1 23 T able 1.3 Rear Panel J2 Connector T erminals and Functions Connector Reference Name Function J2-1 VRMT Remote Output V oltage Programming Select Selects remote output volta ge programming when jumpered to pin 3.
Features and Specifications Rear Panel Connectors and Switch 24 Operating Manual for XFR 2.8kW Series Power Supply Making J2 Connections Make connections to the J2 connector using its screw-type wire clamps. Before making any connections, turn the power su pply OFF and wait until the front panel displays have go ne out.
Features and Specifications Specifications Release 2.1 25 Specifications Electrical Specifications These specifications are warranted over a temperature range of 0 °C to 50 °C. Nominal ambient temperature assumed is 25 °C. Nominal line voltage is 208 V ac, 60 Hz.
Features and Specifications Specifications 26 Operating Manual for XFR 2.8kW Series Power Supply Ta b l e 1 . 4 S pecifications for 7.5 V to 40 V Models Models 7.5-300 12-220 20-130 33-85 40-70 Output Ratings: Output V oltage 1 Output Current 2 Output Power 0-7.
Features and Specifications Specifications Release 2.1 27 1. Minimum output voltage is <0.15% of rated volt age at zero out put setting. 2. Minimum output current is <0.5% of rat ed current at zero outpu t setting when me asured at minimum 10 % of full power load.
Features and Specifications Specifications 28 Operating Manual for XFR 2.8kW Series Power Supply Ta b l e 1 . 5 S pecif ications for 60 V to 600 V Models Models 60-46 100-28 150-18 300-9 600-4 Output .
Features and Specifications Specifications Release 2.1 29 1. Minimum output voltage is <0.15% of rated volt age at zero out put setting. 2. Minimum output curre nt is <0.5% of rated current at zero outpu t setting when measured at minimum 10% of full power load.
Features and Specifications Specifications 30 Operating Manual for XFR 2.8kW Series Power Supply Additional Specifications Input Conditions Figure 1.5 T ypical Input Current Character istics (Based on 100 V , 28 A model.) Rise T ime (No Load, Full Load) : 1 7.
Features and Specifications Specifications Release 2.1 31 Additional Features Remote Programming and Monitoring Switching Frequency nominal 31 kHz (62 kHz output ripple). Output Hold-up Time Greater than 10 ms with interruption of AC line, for nominal AC input and full load.
Features and Specifications Specifications 32 Operating Manual for XFR 2.8kW Series Power Supply Environmental Sp ecification s Operating T emperature Range 0 °C to 50 °C.
Features and Specifications Specifications Release 2.1 33 Mechanical Specifications Front Panel V and I Control 10 -turn voltage and current potentiometers Front Panel V oltage Control Resolution 0.02% of maximum voltage Front Panel V oltage and Current Meters 3.
Features and Specifications Specifications 34 Operating Manual for XFR 2.8kW Series Power Supply Figure 1.6 Dimensional Drawings (Dimensions given are n ominal.
Release 2.1 35 Section 2. Inst allation Introduction This section provides recomm endations and procedures for inspecting, installing, and testing the power supply . Basic Setup Procedure See T able 2.1 for a summary of the basic set up procedure and an overall view of the subsections in Section 2.
Installa tion Inspection, Cleaning, an d Packaging 36 Operating Manual for XFR 2.8kW Series Power Supply Inspection, Cleaning, and Packaging Initial Inspection When you first re ceive your unit: 1. Inspect the unit for scratches and cracks, and for broken switches, connectors, and displays.
Inst allation Returning Power Supplies to the Manufactu rer Release 2.1 37 Returning Power Suppli es to the Manufacturer Return Material Authorization Policy Before returning a product di rectly to Xantrex you must obtain a Return Mat erial Authorization (RMA) number and the correct factory “Ship T o” address.
Installa tion Returning Power Supplies to the Manufacturer 38 Operating Manual for XFR 2.8kW Series Power Supply Packaging for Shipping or Storage Follow these instructions to prepare the unit for shipping or storage.
Inst allation Location, Mounting, and V e ntilation Release 2.1 39 Location, Mounting, and V entilation Use the power supply in rack-mounted or benchtop applications. Rack Mounting The power supply is designed to fit in a standard 19 in. (483 mm) equipment rack.
Installa tion AC Input Power 40 Operating Manual for XFR 2.8kW Series Power Supply AC Input Power AC Input Connector and V oltage Selection The AC input connector is a 3-terminal wi re clamp located on the power supply’ s rear panel. See Figure 2.2 AC Inp ut Cover and St rain Relief.
Inst allation AC Input Power Release 2.1 41 Cord The AC input c ord we recommen d is specified in T able 2.3, “AC W ire Specification”. Add a non-lock ing plug suitable for use in the country in which you are operating. If you require a special cord, call us.
Installa tion AC Input Power 42 Operating Manual for XFR 2.8kW Series Power Supply Figure 2.2 AC Input Cover and S train Relief Screw-on Locknut S tripped Wire Installed in S train Relief Connector T .
Inst allation Functional T ests Release 2.1 43 Functional T ests These functional test pro cedures include power -on and front pan el function checks as well as voltage and current mode operation checks. Refer to front and rear panel diagrams in “Front Panel Controls” on page 17 and “Rear Panel Connecto rs and Switch” on page 18.
Installa tion Functional T ests 44 Operating Manual for XFR 2.8kW Series Power Supply Current Mode Operation Check 1. Ensure the front panel AC power switch is set to OFF . 2. T urn the voltage and current controls on the front panel fu lly counter-clockwise.
Inst allation Load Connection Release 2.1 45 Load Connection This section provides recomm endations for load wires an d how to connect them for both single and multiple load configurations.
Installa tion Load Connection 46 Operating Manual for XFR 2.8kW Series Power Supply Load Wiring Length for Oper ation with Sense Lines For applications using remote sensing, you must limit the voltage drop across each load wire. Figure 2.3 shows some m aximum allowa ble wire lengths for a given load current and wire size.
Inst allation Load Connection Release 2.1 47 Output Cover The power supply comes with a bus bar cover and strain relief. See Figure 2.4. This cover is also installed on models fitted with the high voltage output connector . T o detach the 2-part cover: 1.
Installa tion Load Connection 48 Operating Manual for XFR 2.8kW Series Power Supply 7.5 V to 100 V Models The 7.5 V to 100 V models ar e equipped with output bus bars. T o make a typical load conn ection to a 7.5 V , 300 A power supply: 1. Strip the ends of the wires.
Inst allation Load Connection Release 2.1 49 150 V to 600 V Models The 150 V to 600 V models have a 4-terminal, wire clamp outp ut connector . See Figure 2.6 for a labelled drawing of the wire clamp connector . T o prepare and connect the load wiring: 1.
Installa tion Load Connection 50 Operating Manual for XFR 2.8kW Series Power Supply Inductive Loads T o prevent damage to the power supply from inductive kickback, connect a diode across the output.
Inst allation Load Connection Release 2.1 51 Connecting Multiple Loads Proper connection of distribu ted loads is an important as pect of power supply use. T wo common methods of connection are the parallel power distribution m ethod and the radial power distribution method.
Installa tion Load Connection 52 Operating Manual for XFR 2.8kW Series Power Supply Figure 2.10 Multiple Loads wit h Remote Sensing.
Inst allation Local and Remote Sensing Release 2.1 53 Local and Remote Sensing Use connections at the rear panel J1 0 sense connector to configure the power supply for local or remote sensing of output vo ltage. See Figure 2.1 1 for a drawing of the sense connector .
Installa tion Local and Remote Sensing 54 Operating Manual for XFR 2.8kW Series Power Supply . Figure 2.1 1 J10 Sense Conn ector (Shown with local sense jumpers co nnected.) T able 2.5 Rear Panel J10 Sense Connector T erminals and Functions T erminal Name Function J10-1 Return Sense (–SNS) Remote negative sense connection.
Inst allation Local and Remote Sensing Release 2.1 55 Using Remote Sensing Use remote sensing during voltage mode operation to shift the power supply’ s regulation point from its default position at.
Installa tion Local and Remote Sensing 56 Operating Manual for XFR 2.8kW Series Power Supply 4. T o prevent ground loops , ground the sens e line shield, at one point only , to the power supply’ s return output connection at the load, to the power supply’ s return output at its negative output terminal , or to the power supply’ s chassis.
Release 2.1 57 Section 3. Local Operation Introduction Once you have installed the power supp ly and have connected bo th the AC input power and the load as covered in S ection 2. Installation, the po wer supply is ready to operate in local control mode (that is, operation at the unit’ s front panel).
Local Operation Standard Operation 58 Operating Manual for XFR 2.8kW Series Power Supply Figure 3.1 Operating Modes Const ant V oltage Mode Operation The power supply will operate in constant voltage .
Local Operation Standard Operation Release 2.1 59 Shipped Configuration (Local Control Mode) The factory ships units already configured for local control (front panel) operation. See T able 3.1 for a summary of this configuration. See Figure 1.1 and Figure for front and rear panel diagrams.
Local Operation Standard Operation 60 Operating Manual for XFR 2.8kW Series Power Supply Setting Output V oltage and Current Limit Install the power supply and connect the load as described in Section 2.
Local Operation Using Over V oltage Protection (OVP) Release 2.1 61 Using Over V olt age Protection (OVP) The OVP circuit protects the load in the event of a remote programming error , an incorrect voltag e control adjustment, or a power supply failure.
Local Operation Using Over V oltage Protection (OVP) 62 Operating Manual for XFR 2.8kW Series Power Supply Resetting the OVP Circuit T o reset the OV P circuit after it activates: 1. Reduce the power supply’ s output volta ge setting to below the OVP set point.
Local Operation Using the Shutdown Function Release 2.1 63 Using the Shut down Function Use the Shutdown function to disa ble or enab le the supply’ s output so that you can make adjustments to either the load or the power supply without shutt ing of f the power supply .
Local Operation Using the Shutdown Function 64 Operating Manual for XFR 2.8kW Series Power Supply T able 3.2 Switch Settings for Shut down Circuit L ogic Notes: 1. If switch SW1-7 is ON but there is no si gnal applied, the S/D LED turns on and the power supply will not provide an ou tput until the HIGH signal level i s applied.
Local Operation Using Multiple Supplies Release 2.1 65 Using Multiple Supplies Y ou can operate power supplies of the SAME MODEL with outputs in series or in parallel to obtain increased load voltage or increase d current. Split supply operation gives you two positive outputs or a positive and a negative output.
Local Operation Using Multiple Supplies 66 Operating Manual for XFR 2.8kW Series Power Supply sum of the maximum voltages of each supply (add voltmeter readings, to a maximum of 600 V). The maximum allo wable current for a series string of power supplies is the output current o f a single supply in the string.
Local Operation Using Multiple Supplies Release 2.1 67 Sensing for Parallel Operation Use default local sensing to enhance power sharing between units, as the impedance of the load lines will tend to correct for current imbalance.
Local Operation Using Multiple Supplies 68 Operating Manual for XFR 2.8kW Series Power Supply T wo Positive V o lt ages T o obtain two positive volta ges, connect the negative output terminals of both supplies together in a common connection. The positive output terminals will provide the required voltages with respect to the common connection.
Local Operation Using Multiple Supplies Release 2.1 69 Figure 3.5 S plit Supply Operation of Multiple Supplies (Positive-negative Supply) (Local sense lines shown are default J10 connections.
Local Operation Over T emperature Protection (OTP) 70 Operating Manual for XFR 2.8kW Series Power Supply Over T emperature Protection (OTP) The OTP function allows you to select how the power supply reco vers from an over temperature shutdown using the rear p anel switch SW1-8.
Local Operation User Diagnostics Release 2.1 71 User Diagnostics If your power supp ly is not performing as described in this operating manual, run through the procedures and checks in th is section before calling your service technician. These procedures are confined to operator-level functions onl y and do not require cover-off servicing.
Local Operation User Diagnostics 72 Operating Manual for XFR 2.8kW Series Power Supply Ta b l e 3 . 4 User Diagnostics Symptom Check Further Checks and Corrections No output and the display is blank. Is input voltage within specified range? Connect to appropriate voltage source.
Release 2.1 73 Section 4. Remote Operation Introduction The rear panel switches and connector on th e power supply allow you to program the supply with an analog device or to o utput readback signals.
Remote Operation Remote Analog Programming of Output V oltage and Current Limit 74 Operating Manual for XFR 2.8kW Series Power Supply Remote Analog Programming of Ou tput V oltage and Current Limit Re.
Remote Operation Remote Analog Programming of Output V oltage and Current Limit Release 2.1 75 4. Connect the program ming source(s) to the mating J2 connector as shown in Figure 4.1, observing the correct polarity for voltage sources. Ensure that the mating connecto r is plugged securely into the rear panel connector .
Remote Operation Remote Analog Programming of Output V oltage and Current Limit 76 Operating Manual for XFR 2.8kW Series Power Supply Ta b l e 4 . 2 Power Supply Settings for Dif ferent Progra mming S.
Remote Operation Remote Analog Programming of Output V oltage and Current Limit Release 2.1 77 Figure 4.1 Connecting Programming Sources to J2 Connector.
Remote Operation Remote Monitoring of Output V oltage and Current 78 Operating Manual for XFR 2.8kW Series Power Supply Remote Monitoring of Output V olt age and Current Readback Signals The J2 connector on the rear panel provid es access to calibrated readback signals for remote monitoring of the ou tput voltage and current.
Release 2.1 79 Section 5. Calibration Introduction Adjustments to programming and readback accuracy for the power supply are made using cover-of f procedures which must be performed by a service technician. Calibration Setup Service Environment and Precautions • Follow established antistatic procedures.
Calibration Calibration Setup 80 Operating Manual for XFR 2.8kW Series Power Supply Accessing Calibration Potentiome ters Y ou will need to remove the power supply ’ s cover to access the programming and readback calibration potentiometers wh ich are located on the A2 PCB.
Calibration Calibration Setup Release 2.1 81 Removing Option Card If there is a GPIB or RS-232 option card (PCB) installed inside the power supply , you will have to remove it to access the calibration potentiometers. T ool Required: Phillips #2 screwdriver 1.
Calibration Calibrating for Programming Accurac y 82 Operating Manual for XFR 2.8kW Series Power Supply Calibrating for Programming Accuracy The factory calibrates the offset and rang e of the voltage and current programming circuits to within 1% for the default 0- 10 Vdc progra mming signals.
Calibration Calibrating for Programming Accuracy Release 2.1 83 Current Limit Programming Circuit Calibration 1. Ensure that the power supply is turned OFF . Disc onnect any load. 2. Connect the program source between J2 connector terminals 8 (output current limit programming input) and 7 (c urrent program signal return).
Calibration Calibrating for Readback A ccuracy 84 Operating Manual for XFR 2.8kW Series Power Supply Calibrating for Readback Accuracy The factory calib rates the of fset and ra nge of the output voltage and current monitor circuits to within 1% for the default 0- 10 Vdc scales.
Calibration Calibrating for Readback Accuracy Release 2.1 85 Output Current Monitor Circuit Calibration 1. Ensure that the power supply is turned OFF . Disc onnect any load. 2. Set SW1 switch 6 OPEN to select 0-5 V output current monitor range, CLOSED for 0-10 V .
Calibration Calibrating for Readback A ccuracy 86 Operating Manual for XFR 2.8kW Series Power Supply.
.
Xantrex Technology Inc. 8999 Nelson W ay Burnaby , British Columbia Canada V5A 4B5 604 422 8595 T el 604 421 3056 F ax 800 667 8422 T oll Free North America prg.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Xantrex Technology XFR 2800 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Xantrex Technology XFR 2800 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Xantrex Technology XFR 2800 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Xantrex Technology XFR 2800 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Xantrex Technology XFR 2800, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Xantrex Technology XFR 2800.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Xantrex Technology XFR 2800. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Xantrex Technology XFR 2800 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.