Manuale d’uso / di manutenzione del prodotto Link 2000 del fabbricante Xantrex Technology
Vai alla pagina of 40
O O O O O WNERS MANU WNERS MANU WNERS MANU WNERS MANU WNERS MANU AL AL AL AL AL Xantrex Link 2000 Inverter Controller and Dual Battery Monitor Owner's Manual Link 2000 Contro l Inver t Idle Mode .
2 T ABLE OF CONTENTS One Page Summary of Features Center Introduction and Special Notes 3 Monitor Functions 4–5 Inverter and Charger Functions 5 Status Line and Starting and Stopping Equalize 6 Setu.
3 INTRODUCTION AND SPECIAL NOTES The LINK 2000 is an integrated battery monitor and inverter/charger control. It displays the critical information necessary for 12 V or 24 VDC system battery management and allows precise control of critical inverter and charger features.
4 MONIT OR FUNCTIONS Please also refer to the one-page summary of features in center of this manual. The small blue legends indicate Setup functions described later . BA TTER Y SELECT The battery to be monitored is selected by pressing the #1 or #2 switch.
5 INVERTER/CHARGER FUNCTIONS MARINE AND R V OPERA TING TIP When utility power is available, any loads normally supplied by the inverter are automatically transferred to utility power through the internal transfer switch. When utility power is not available the loads run on stored energy in the battery .
6 ST A TUS LINE There are four LED status indicators to show the presence of AC power and the charger's cycle state. AC IN: Green LED on when AC is present. CHARGE: Red LED on when charger is in Charge mode. Flashes Red when charger is in Equalize mode.
7 SETUP The LINK 2000 has been set up with default values chosen to work with a typical system. Normally the only values that must be changed are: 1) Battery capacity (page 9) 3 ) Battery type (liquid or gel) (F02 page 1 1). 2) Ambient T emperature (F03 page 1 1) 4) Peukert's exponent (F08 page 13).
8 INVERTER SETUP IDLE MODE: The default value is 4 watts. This means it takes a 4-watt AC load to turn the inverter on from its low power idle mode. Setting a value of 0 watts means the inverter is always on. The low power idle current is about 0.25 amps.
9 MONIT OR SETUP Normally the only MONIT OR SETUP parameter that must be changed is BA TT CAP (see bottom of this page). Please read the section on selecting charged parameters (page 21–22) before changing CHARGED V or CHARGED % default values. (See FUNC SETUP on page 10 for other system values that may need to be changed.
10 FUNCTIONS SETUP FUNC: The FUNC (Function) mode is used to set up special functions or features that are not commonly changed. They might be thought of as internal softwar e switches that allow the selection of special functions, or values that, once set, are seldom changed.
11 F02 - BA TTER Y TYPE 0 = LIQUID CELL (DEF AUL T) 1 = GEL CELL (ST ANDARD) 2 = GEL CELL (F AST CHARGE) 3 = AGM (Absorbed Glass Mat) This function (Default: T ype 0, standard liquid cells) sets the appropriate charge and float voltages for the FREEDOM charger (see table below) and sets an appropria t e Peukert exponent.
12 Freedom units produced prior to serial #100,000 have temperature compensation only for warm or cool environments. The temperature setup sets the voltages as per below: TEMP TYPE 0 (Liquid) TYPE 1 (Gel 1) Accept Float Equalize Accept Float Equalize Above 80 °F 13.
13 F08 - SET PEUKER T'S EXPONENT DEF AUL T = 1.25 RANGE = 1.00–1.50 STEP = 0.01 Sets the exponent for Peukert’ s equation. A setting of 1.00 defeats Peukert's calculation. See pages 24–27 for a discussion of Peukert's equation and typical values for various batteries.
14 F13 SET DISCHARGE FLOOR DEF AUL T = 100% RANGE = 50%–100% STEP = 5% When this option is activated, you may set a discharge floor for each battery bank. When the discharge floor is set to 50%, the T ime Remaining display reports time remaining until the battery reaches the 50% discharged level.
15 DA T A MODE DA T A: The DA T A mode is used to recall key historical information about the battery (battery banks). T o access the DA T A mode: 1) Select Battery #1 or #2 to review its data. 2) Press and hold the SETUP button until the green LED begins to flash then release the button.
16 HOW T O USE THE LINK CONTROL P ANEL BA TTER Y MANAGEMENT PHILOSOPHY : Recharge When the Battery is 50% Discharged! The LINK 2000 is a guide to the battery's state of charge. Our Mid-Capacity Rule says you should begin charging when your LINK 2000 shows that 50% of battery capacity has been consumed.
17 parameters. The battery will be gassing and you will see an accumulation of a large number of amp hours each day . This is a clear indication that you are destroying your battery by overcharging. Check your LINK 2000 before turning off a charging source to see that you have not accumulated too many overcharge amp hours.
18 THE F ACT OR Y DEF AUL T V ALUES FOR CHARGING: Battery capacity: = 200 Ah (800 Ah if F05 is ON) Accept V oltage: = 14.4 volts for 12-volt systems (for wet cell batteries) = 28.8 volts for 24-volt systems (for wet cell batteries) Charged Current: = 2% (of battery capacity) Float V oltage: 0.
19 HOW T O TELL WHEN A BA TTER Y IS FULL Y CHARGED (CHARGED BA TTER Y P ARAMETERS) MUL TIPLE ST AGE CHARGING SYSTEMS If you are using the charger in the FREEDOM, the battery is charged when the system switches to the Float cycle.
20 SYNCHRONIZING YOUR LINK 2000 T O A CHARGED BA TTER Y A charged battery has zero Ahrs removed. Synchronizing your LINK 2000 to read zero when the battery is charged ensures that you always know the net number of amp hours removed.
21 MANUALL Y SELECTING THE CHARGED BA TTER Y P ARAMETERS DISCUSSION: HOW THE LINK 2000 USES THESE V ALUES The LINK 2000 allows the setup of specific charged parameters. The factory default values have been carefully chosen to work on most systems, including constant voltage and multiple step charging systems.
22 RULES FOR CHANGING THE CHARGED BA TTER Y P ARAMETERS If you must change the Charged Parameters please use the following rules. If the charged parameters are not correctly selected, the LINK 2000 will never r ecalculate the CEF . For example: (1) If your charging system only reaches 13.
23 RESET / INFO FUNCTIONS The drawing below shows the Reset/Info Functions layout. T o access these, press the SETUP BUTTON for ten seconds. The time is long to avoid unintentionally entering this mode. When the green LED begins to flash quickly (about three times per second) select the Advanced Function you wish by consulting this drawing.
24 HIGH DISCHARGE RA TES & PEUKERT'S EQUA TION Peukert's Equation describes the effect of different discharge rates on battery capacity . As the discharge rate increases the available battery capacity decreases. The tables on pages 25, 26 and 27 have typical values of " n " for common batteries.
25 20 Hr rating 60 70 85 86 90 95 105 108 112 120 130 150 170 180 208 210 216 221 225 Reserve Minutes 60 1.41 90 1.22 1.32 1.46 1.47 120 1.09 1.17 1.30 1.31 1.34 1.39 1.48 1.50 130 1.05 1.13 1.25 1.26 1.30 1.34 1.42 1.45 1.49 150 1.06 1.17 1.18 1.21 1.
26 The following table contains values for the exponent "n" for various batteries and manufacturers. They are calculated from the 20-hour rating and the Reserve Minutes @ 25 A as supplied by the manufacturer . Page 27 shows how the calculation is performed.
27 Surr ette and Rolls Batteries Model V olts Res. Min. 20-Hr . Rating "n" EHG-208 6 345 208 1.42 EIG-225 6 350 225 1.54* EIG-262 6 395 262 1.72* 24/90 12 165 90 1.16 27/12M 12 190 1 12 1.23 30H/108 12 230 108 1.08 HT/4D 12 348 1 70 1.15 HT/8D 12 450 2 21 1.
28 ERROR CODES AND TROUBLESHOOTING The following error codes are displayed when the LINK 2000 detects a problem. The display alternates between the selected monitoring function and the Error Code. The Error Code continues to flash until the error is corrected.
29 E-10 LINK 2000 DEPOWERED: Displayed on power up and when power has been interrupted or dipped below the operating voltage of the LINK 2000. May be caused by voltage dips during engine starting if the meter is powered by a starting battery .
30 MICROPROCESSOR RESET PROCEDURE The LINK 2000 uses a microprocessor to perform all of its calculations and functions. W e have worked very hard to ensure a stable, trouble-free product. However , like all computer products, the unit is sometimes susceptible to power supply dips or surges that can cause erratic behavior or memory errors.
31 RESETTING MEMOR Y TO F ACTO R Y V ALUES: If some portions of the memory have been "corrupted" you should consider resetting to the factory default values and then changing any specific values you need to. This ensures a "clean slate" for your new setup.
32 SETUP AND HISTORICAL DA T A SUMMAR Y The following table is a summary of the values that may be changed through setup or by accumulating historical data. The column on the right is provided to write down your setup values or historical data. Be sure and know these values before calling for customer service.
33 W ARRANTY What does this warranty cover? This Limited Warranty is provided by Xantrex Technology, Inc. (“Xantrex”) and covers defects in workmanship and materials in your Xantrex Link 2000. This warranty lasts for a Warranty Period of 12 months from the date of purchase at point of sale to you, the original end user customer.
34 Disclaimer Product THIS LIMITED WARRANTY IS THE SOLE AND EXCLUSIVE WARRANTY PROVIDED BY XANTREX IN CONNECTION WITH YOUR XANTREX PRODUCT AND IS, WHERE PERMITTED BY LAW, IN LIEU OF ALL OTHER WARRANTI.
35 Return Procedure 1 . Package the unit safely, preferably using the original box and packing materials. Please ensure that your product is shipped fully insured in the original packaging or equivalent. This warranty will not apply where the product is damaged due to improper packaging.
36 REQUIRED READING Before wiring the LINK 2000, install the shunt as indicated. All wiring should be done before installing the fuses. GENERAL NOTES 1) W iring to the LINK 2000 should be #16 or #18 A WG. (Lar ger wire is acceptable, but not necessary .
37 remember that instrumentation and other loads grounded directly to the engine block will not be measured unless their negatives are relocated to the load side of the Battery Shunt. Special high current shunts are also a solution and may be ordered from us.
38 The VIOLET WIRE (B2 V) supplies Battery #2 voltage for sensing. It should be supplied directly from Battery #2. Be sure to install the 2-amp fuse shown in the drawing. NOTE: If only one battery is to be monitored, connect the VIOLET wire to the BLUE wire.
39 SPECIFICA TIONS Power to Link 2000 Power Supply V oltage 9–40 volts DC (not for use with 32 V systems) Power Supply Current 28 mA (typical; backlight adds 1 to 18 mA ) Measurements V oltage Range 8.5–50 volts DC V oltage Resolution 0.05 volts DC V oltage Accuracy + 0.
Xantrex Technology Inc. Toll free 1 866 XANTREX (1 866 926 8739) Direct 1 604 422 2777 Fax 1 604 420 2145 customerservice@xantrex.com www.xantrex.com part #445-0198-01-01 Printed in the U.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Xantrex Technology Link 2000 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Xantrex Technology Link 2000 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Xantrex Technology Link 2000 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Xantrex Technology Link 2000 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Xantrex Technology Link 2000, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Xantrex Technology Link 2000.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Xantrex Technology Link 2000. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Xantrex Technology Link 2000 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.