Read these instructions bef ore operating the machine MOD EL: D250 (115V) 10070100 Beginning with Serial No. 1000054537 86038570 05/11/07 PRV NO. 98828 AB CARPET EXTRACTOR Operating Instru ctions (ENG.
TABLE OF CONTENTS D-250 86038570 05/11/07 1 Data Log/Table of Contents .................... 1 Safety Instructions ................................... 2 Grounding Instructions ............................ 3 Operations ..................................
SAFETY INSTRUCTIONS D-250 86038570 05/11/07 2 IMPORTANT SAFETY INSTRUCTIONS When using an electrical appliance, basic precaution must always be followed, including the following: READ ALL INSTRUCTIONS BEFORE USING THIS MACHINE. This machine is for commercial use.
GROUNDING INSTRUCTIONS NOTE: In Can ada, th e use o f a tem p orary adaptor i s no t p ermit te d by the C anadia n Electri cal Co de PROPER GR OUND ING (115V) Meta l Sc r e w A daptor Grounded Out let Box Fig. A Fig. B Fig. C Tab For Gr ounding S crew Grounded Outlet Grounding P in A dapto r THIS PRODUCT IS FOR COMMERCI AL USE ONLY.
OPERATIONS D-250 86038570 05/11/07 4 CARPET INSPECTION: Determine precisely what areas you a re going to clean. Note problem areas in the carpe t or tack strip. Look for loose carpet, heavily damaged a rea s, discolored stains, or grease spots that will require prespotting.
OPERATION D-250 86038570 05/11/07 5 HEATER OPERATION The disconnect fittings o n the heater will become extremely hot during operation. Allow sufficient time to cool, or run solution through the machine with the heater turned off before disconn ecting the or performing any maintenance on the h eater.
MAINTENANCE D-250 86038570 05/11/07 6 DAILY MAINTENANCE: (At the end of each working day): 1. Flush the entire system, including floor t ool, hand tool, etc., with 1 to 3 gallons of clean, hot water. 2. Vacuum out the solution tank . 3. Rinse tank with fresh water.
MAINTENANCE D-250 86038570 05/11/07 7 SERVICE SCHEDULE MAINTENANCE DAILY WEEKLY QUARTERLY Check machine for cord damage * Check recovery dome an d gasket for damage and cleanliness * Check hose s f or.
MAINTENANCE D-250 86038570 05/11/07 8 ONLY QUALIFIED MAINTENANCE PE RSONNEL ARE TO PERFORM THE FOLLOWING REPAIRS. VACUUM MOTOR REPLACEME NT 1. Turn off all switches and unplug machi ne. 2. Remove recovery tank. 3. Locate the vacuum motor wires and discon nect at the connector.
MAINTENANCE D-250 86038570 05/11/07 9 D-250 PUMP MAINTENA NCE Per manufacturer’s recommendatio ns the following main tena nce should be performed utilizi ng noted kits: 1.) 500 hours-Kit 86201080 – PRV NO. 250 -75A replaces the V-packing, wave washer, pa cking spreader a nd plunger guide.
TROUBLESHOOTING D-250 86038570 05/11/07 1 0 TROUBLE SHOOTING CHAR T PROBLEM POSSIBLE CAUSE SOLUTION No power to machine Dead electrical circuit Check building circuit breaker o r fuse box. Electrical shock Faulty power cord Replace. Equipment not grounding Follow grounding instructions exa ctly.
TECHNICAL SPECIFICATIONS D-250 86038570 05/11/07 11 TECHNICAL SPECIFICATIONS ELECTRICAL: 115 V, 60 Hz, 15 Amps per power cable ((D250 ) 230 V, 50 Hz, 15 Amps (D250IE) ELECTRIC VACUUM MOTOR (1) –2/1.25 HP, 2 stage, Waterlift –150” (381cm) SOLUTION PUMP 250 psi, adj.
NOTES: D-250 86038570 05/11/07 12.
RECOVERY TANK ASSEMBLY D-250 86038570 05/11/07 13 1 2 3 4 5 6 7 8 9 10 11 12 14 15 16 17 18 19 20 21 22 23 24 25 26 27 13 28 13 34 35 36 13 29 35 37 30 31 32 33.
RECOVERY TANK ASSEMBLY D-250 86038570 05/11/07 14 REF PART NO. PRV NO. QTY DESCRIPTION SERIAL NO. FROM NOTES: 1 86033260 05151 1 TUBE ASM, RECOVERY TANK 2 86242230 500009 1 LABEL, WARNING 3 86002620 2.
CONTROL PANEL GROUP D-250 86038570 05/11/07 15 5 4 6 2 18 19 3 9 1 16 11 13 17 10 8 12 14 7 15.
CONTROL PANEL GROUP D-250 86038570 05/11/07 16 REF PART NO. PRV NO. QTY DESCRI PTION SERIAL NO. FROM NOTES: 1 86199650 070-08 1 FAN 105 CFM AXIAL 2 86090870 61367 1 PANEL ASM, CONT.
VACUUM GROUP (LOWER) D-250 86038570 05/11/07 17 4 6 5 7 3 2 10 11 1 8 9 12.
VACUUM GROUP (LOWER) D-250 86038570 05/11/07 18 REF PART NO. PRV NO. QTY DESCRIPTION SERIAL NO. FROM NOTES: 1 86274980 70335 1 SCR, 10-32 X 1/2 PHTR GRN/GRND 2 86256480 70813 3 STUD, 14/20 X 3.
PUMP & HEATER GROUP (200 PSI) D-250 86038570 05/11/07 19 1 2 5 7 6 8 9 10 11 16 15 12 13 14 3 4.
PUMP & HEATER GROUP (200 PSI) D-250 86038570 05/11/07 20 REF PART NO. PRV NO. QTY DESCRIPTION SERIAL NO. FROM NOTES: 1 86199640 030-16 1 ELBOW, 1/4 NPT STREET LONG 90D 2 86200260 151-50C 1 HOSE, PULSE 47.
SOLUTION TANK ASSEMBLY D-250 86038570 05/11/07 21 10 11 13 12 14 16 8 7 6 11 25 24 5 4 27 1 26 29 28 2 3 1 11 12 23 17 18 19 15 30 35 16 36 37 12 33 34 32 36 20 22 11 12 9 20 21 39 38 40 40.
SOLUTION TANK ASSEMBLY D-250 86038570 05/11/07 22 REF PART NO. PRV NO. QTY DESCRIPTION SERIAL NO. FROM NOTES: 1 86201290 280-02 2 RIVET AL. 3/16 X 1/2 CLOSED 2 86201500 260-71 1 SOLUTION COVER D/B 3 8.
SPARE PARTS D-250 86038570 05/11/07 23 SUGGESTED SPARE PARTS PART NUMBER PRV NO. DESCRIPTION SERIAL NO. FROM 86199890 100-04A FUSE 3 AMP 200 PSI 86199240 250-33A BPR REPAIR KIT PUMPTEC 86201810 130-14.
115V WIRING DIAGRAM D-250 86038570 05/11/07 24.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Windsor D250(115V) 10070100 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Windsor D250(115V) 10070100 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Windsor D250(115V) 10070100 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Windsor D250(115V) 10070100 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Windsor D250(115V) 10070100, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Windsor D250(115V) 10070100.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Windsor D250(115V) 10070100. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Windsor D250(115V) 10070100 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.