INSTALLATION INS TR UCTIONS 30" (76.2 CM) FREESTANDING GAS RANGES with standard clean o v en T able of Contents RANGE SAFETY ........................................ ......................................... ........................... 2 INSTALLATION REQUIREMENTS .
2 RANGE SAFETY You can be killed or seriously injured if you don't immediately You can be killed or seriously injured if you don't follow All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.
3 INST ALLA TION REQUIREM ENTS T ools and P ar ts Gat her the r equ ired tools an d parts befor e st artin g instal latio n. Read and fol low the instruction s pr ovid ed with any tools listed here. To o l s n e e d e d Parts supplied Check that all parts are include d.
4 Location Require ments IMPORT AN T : Observe al l governi ng codes and ordinances. D o not obstruct flow of comb ustion and ventilation air . ■ It is th e install er’ s respon sibili ty to comp ly with i nstalla tion clearances spe cified on the model /serial rating pla te.
5 Cabinet Dimensions Cabinet opening dimens ions shown a re for 2 5" (64.0 cm) counter top depth, 24" (61.0 cm) base cabi net dept h and 36" (91 .4 cm) count ertop heigh t. If the cabin et depth is greater than 24" (6 1.0 cm), oven frame must extend b eyond cabinet fr onts by ½" (13 .
6 Gas Supply Requirements Observe all gover ning codes a nd or dinances. IMPORT AN T : This in stallati on must conform wi th al l local codes and ordinances. In the absence of local codes, installa tion must conform with America n National Standard, National Fuel Gas Code ANSI Z 223.
7 Burner Input Requir ements Input ratings show n on the model/s erial rating plate ar e for elevation s up to 2, 000 ft (609.6 m). For elevati ons above 2,000 ft (6 09.6 m), ra tings ar e re duced at a rate of 4% for each 1,000 ft (3 04.8 m) above sea level (not appl icable f or Can ada).
8 If cabin et opening is wider than that s pecified in the “Location Requirements” s ection, adjust template so range w ill be centered in cab inet openin g. 5. T o mount anti-tip bracket to wood floor , drill two ¹⁄₈ " (0.32 cm) holes at the posi tions marked on the bracket templat e.
9 Mak e Gas Connection T ypical ri gid pipe c onn ectio n A combinat ion of pipe fit tings must be use d to connect the ran ge to the exis ting gas lin e. Y o ur connections may be different, according to the supply l ine type, size and loca tion. 1. Apply p ipe-joint compou nd made for u se with LP gas to all pipe th r ead con nections.
10 5. Close the broiler door . 6. Remove cooktop bur ner caps and grat es from parts pack age. Ali gn n otche s in bu rner caps w ith pins in bu rner base. Bur ner caps sh ould be level when properly positioned. If bur ner caps are not properly posit ioned, surface bur ners will not li ght.
11 2. Insert a small flat-b lade screwdr iver into the valve ste m. T ur n the val ve adjust ing screw to obta in the s mallest fl ame that w ill not go out when the cont r ol of a cold bur ner is quickl y turn ed from “HI” to “Lo.” T urn right t o decrease flame heigh t.
12 GAS CON VER SIONS Gas conversions fr om Natural gas to LP gas or from L P gas to Natu ral gas mus t be don e by a qualifi ed inst aller . LP Gas Con version T o Co nvert Gas Pr essure Regulator 1. T urn manual sh utof f valv e to the “c losed” positio n.
13 T o Co nvert Surface Bur ners 1. Remove bur ner grate, bur ner caps and bur ners. 2. Locate LP gas ori fice spud s for top bu rners i n the litera ture bag incl uded w ith th e ran ge. Thr ee L P gas spuds ar e stampe d “88” and one “96 .” 3.
14 Complete Con version 1. Refer to the “Make Gas Connec tion” section for properly connecti ng the range to the gas supply . 2. T u rn the manual shutoff valve in th e gas supply line t o the open position.
15 T o Co nvert Surface Bur ners 1. Remove bur ner grate, bur ner caps and bur ners. 2. Locate the Nat ural gas orifice spuds for t op burners in the literatu re bag incl uded wi th the ran ge. Thr ee n atural gas spuds are stampe d “149” and one “165.
3. Locat e Natura l gas o rifice s pud stam ped “47” in the b ag containing literature suppli ed with the range. 4. Us e a ³⁄₈ " combina tion wrench and remove the LP gas orific e spud . 5. Install the numbe r “47” LP ga s spud . IMPORT AN T : Do n ot overti ghte n.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Whirlpool W100329708 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Whirlpool W100329708 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Whirlpool W100329708 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Whirlpool W100329708 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Whirlpool W100329708, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Whirlpool W100329708.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Whirlpool W100329708. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Whirlpool W100329708 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.