Microwave Hood Combination

PRODUCT MODEL NUMBERS OVERALL DIMENSIONS

GH5176XP GH5184XP

GH6177XP GH6178XP

Electrical: A 120 Volt, 60 Hz, AC only, 15- or 20-amp fused electrical supply (or circuit breaker) is required. (A time-delay fuse or circuit breaker is recommended.) It is recommended that a separate circuit serving only this appliance be provided.

17¹⁄₈" (43.5 cm)

15⁷⁄₈" (40.3 cm)

9 2 ₈⁄⁷ ) m c 9 . 5 7 ( "

) m c 1 . 9 3 (

5 1 ₈⁄³ "

CABINET OPENING DIMENSIONS

VENTING REQUIREMENTS

A B

A 3¹⁄₄" x 10" (8.3 x 25.4 cm) rectangular or 6" (15.2 cm) round vent should be used. The total length of the vent system including straight vent, elbow(s), transitions and wall or roof caps must not exceed the equivalent of 140 ft (42.7 m) for either type of vent. For best performance, use no more than three 90° elbows. To calculate the length of the system you need, add the equivalent length for each vent piece used in the system. See the following examples:

30" (76.2 cm)

A B C

min.

12" (30.5 cm) min. 14" (35.6 cm) max.

66" (167.6 cm) min.

D E F G

A. Rectangular to round transition piece: 3¹⁄₄" x 10" to 6" = 5 ft

(8.3 x 25.4 cm to 15.2 cm = 1.5 m) B. Roof cap: 3¹⁄₄" x 10" = 24 ft (8.3 x 25.4 cm = 7.3 m) C. 90° elbow: 3 " x 10" = 25 ft (8.3 x 25.4 cm = 7.6 m) D. 90° elbow: 6" = 10 ft (15.2 cm = 3 m)

E. Wall cap: 3¹⁄₄" x 10" = 40 ft (8.3 x 25.4 cm = 12.2 m) F. 45° elbow: 6" = 5 ft (15.2 cm = 1.5 m) G. 90° flat elbow: 3¹⁄₄" x 10" = 10 ft (8.3 x 25.4 cm = 3 m)

A. 2" x 4" wall stud B. Grounded 3 prong outlet

6" (15.2 cm) vent system = 73 ft (22.2 m) total

A B

6 ft (1.8 m)

Whirlpool GH5176XP — 6" (15.2 cm) vent system = 73 ft (22.2 m) total diagram (page 1)
Fig. 1 · 6" (15.2 cm) vent system = 73 ft (22.2 m) total

3¹⁄₄" x 10" (8.3 x 25.4 cm) vent system = 73 ft (22.2 m) total

A B

2 ft (0.6 m)

6 ft (1.8 m)

2 ft (0.6 m)

C D

A. Two 90° elbows = 20 ft (6.1 m) B. 1 wall cap = 40 ft (12.2 m) C. 1 rectangular to round transition piece = 5 ft (1.5 m) D. 2 ft (0.6 m) + 6 ft (1.8 m) straight = 8 ft (2.4 m)

A. One 3¹⁄₄" x 10" (8.3 x 25.4 cm) 90° elbow = 25 ft (7.6 m) B. 1 wall cap = 40 ft (12.2 m) C. 2 ft (0.6 m) + 6 ft (1.8 m) straight = 8 ft (2.4 m)

Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.

Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.

Ref. 8205139

® · 08-23-05

Fai una domanda su Whirlpool GH5176XP

I possessori del prodotto e il nostro team di solito rispondono entro 24 ore, e la tua domanda sarà utile anche ad altri.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Nessuna domanda ancora per il dispositivo Whirlpool GH5176XP

Invia la prima domanda: risponderanno altri possessori o il nostro team.

Documento originale

Whirlpool GH5176XP manuale in PDF

1 pagine·183 KB·Monitor per computer·PDF
Clicca su qualsiasi pagina in alto per aprirla qui
Pagina 1 / …
100%
Caricamento pagine…