Manuale d’uso / di manutenzione del prodotto UL-ES-Parkway-WH10 del fabbricante Westinghouse
Vai alla pagina of 24
UL -ES-Parkwa y-WH10 OWNER' S MANUAL MANUAL DEL USUARIO Please write model number here for future reference: / Por fav or , incluya el número del modelo aquí para futura referencia: Net Weight: 14.
2 UL -ES-Parkwa y-WH10 1. Installation work and elec trical wiring must be done by qualified person(s) in accordance with all applicable codes and standards (ANSI/NFP A 70-1999), including fire-rated construction. 2. Use this unit only in the manner intended by the manufacturer .
3 UL -ES-Parkwa y-WH10 1. El trabajo de instalación y el cableado eléctrico los deben efec tuar personas calificadas cumpliendo con todos los códigos y las normas aplicables (ANSI/NFP A 70-1999), incluyendo las de incendio. 2. Use esta unidad sólo de la manera en que el fabricante quiere que se haga.
4 UL -ES-Parkwa y-WH10 FEA TURES C ARA C TERÍSTICAS DOWNROD INST ALLA TION INST ALACIÓN CON V ARILLA VERTICAL For normal ceilings Para cielorrasos normales V AUL TED CEILING INST ALLA TION INST ALAC.
5 UL -ES-Parkwa y-WH10 COMBO-BLADE Combo-Blades feature two high quality finishes on one blade. Select the one that best complements your decor , or change the style with just a flip of the blade. NOTE: Combo-Blade finishes var y , depending upon model.
6 UL -ES-Parkwa y-WH10 6 Unpack and inspect fan carefully to be certain all conten ts are included. T urn off power at fuse box to avoid possible elec trical shock.
7 UL -ES-Parkwa y-WH10 Remove the screws and star washers from the two mating holes (1) on the canopy . Loosen (do not remov e) the screws in the mating slots (2) on the canopy . Rotate the mounting bracket and remove from the canopy . Quite los tornillos y las dos arandelas en estrella de los dos orificios coinciden tes (1) del dosel.
8 UL -ES-Parkwa y-WH10 MOUNTING BRA CKET INST ALLA TION INST ALACIÓN CON SOPORTE DE MONT A JE Install mounting brack et to outlet box in ceiling using the screws and washers provided with the outlet box. Instale el soporte de montaje a la caja de embutir del cielorraso con la tornillería suministrada con la caja de embutir .
9 UL -ES-Parkwa y-WH10 FL USH MOUNT OPTION OPCIÓN DE INST AL A CIÓN AL RAS 6 G ui de m ot o r wi r es t h ro u gh t he b as e of t h e c a no p y a s sh o w n a n d a t ta c h ca no p y directly to top of motor housing with flush mount screws and lock washers provided .
10 UL -ES-Parkwa y-WH10 9 Loosen downrod ball (1) fr om downr od (2) by removing set scr ew (3). Afloje la esfera de la varilla vertical (1) de la varilla vertical (2) quitando el tornillo (3).
11 UL -ES-Parkwa y-WH10 EX TENDED DOWNROD OPTION OPCIÓN C ON VARILLA VERTIC AL MÁS LARGA 10 S li de d o wn r od b al l (1 ) o ff o f d o wn r o d a n d re m ov e p i n ( 2 ). De s li c e l a es f er a de l a v ar il l a v ert ic a l ( 1 ) h a st a se p ar a rl a de l a v ar i ll a v ert ic a l y q u it e el p as a do r (2 ) .
12 UL -ES-Parkwa y-WH10 Feed motor lead wires through downrod/canopy assembly and inser t downrod into downrod yok e. Make sure to align hole in downrod with the hole in downrod yoke. Install yoke cross pin (1) through yok e and downrod . Inser t clamp pin (2) into cross pin until it snaps into place.
13 UL -ES-Parkwa y-WH10 MOUNTING MONT A JE 14 W i th b r ac k et h ol d in g fa n as s em bl y , ma k e el ec tr i ca l co n ne ct io n s u s in g th e following step for wiring instruc tions .
14 UL -ES-Parkwa y-WH10 WIRING OPTIONS OPCIÓN DE CABLEADO 16 Follo w diagram above to make wiring connec tions for wall contr ol operation. 15 Follo w diagram above to make wiring connec tions for fan pull chain contr ol.
15 UL -ES-Parkwa y-WH10 SECURE TO CEILING ASEGURE EL VENTILADOR AL CIEL ORRASO 17 1 3 2 The canopy has two mating slots (1) and t wo mating holes (2). P osition both slots on canopy directly under and in line with t wo screws in the mounting bracket (3).
16 UL -ES-Parkwa y-WH10 Check the motor for plastic shipping stabilizer tabs (1), and remove them if they are present. Attach blade assembly to motor using the noise -dampening motor gaskets (2) and motor screws provided. Tighten screws securely . NOTE: Some models do not utilize motor gaskets , washers , or stabilizer tabs.
17 UL -ES-Parkwa y-WH10 Attach the switch housing cap using three small screws provided. Conecte la tapa del alojamiento del interrupt or con los tres tornillos pequeños incluidos. Connect the wire plugs from the motor (1) to the wire plugs from the light kit (2), white to white, and black to black.
18 UL -ES-Parkwa y-WH10 23 6 1 2 3 4 5 Install glass (1) onto light kit and tighten rubber/ metal washer (2) (rubber side facing the glass), and nut (3) onto bottom of glass. Make sure ceiling fan pull chain is threaded through the side hole in the bottom of the glass.
19 UL -ES-Parkwa y-WH10 24 Assemble decorative fob and extension chains from har dware bag to fan pull chains by inser ting end of chain into chain coupling.
20 UL -ES-Parkwa y-WH10 Operation T urn on the power and check operation of fan. T he pull chain controls the fan speeds as follows: 1 pull - high; 2 pulls - medium; 3 pulls - low; 4 pulls - off. Speed settings for warm or cool wea ther depend on factors such as room size, ceiling height, number of fans and so on.
21 UL -ES-Parkwa y-WH10 Operación Encienda el ventilador y verifique su funcionamiento . La cadenilla de tiro contr ola las velocidades del ventilador de la siguiente manera: 1 jalón – rápida; 2 jalones - mediana; 3 jalones - lenta; 4 jalones - apagado .
22 UL -ES-Parkwa y-WH10 TROUBLESHOOTING GUIDE If you have difficulty operating your new ceiling fan, it may be the result of incorrect assembly, installation, or wiring. In some cases, these installation errors may be mistaken for defects. If you experience any faults, please check this T rouble Shooting Chart.
23 UL -ES-Parkwa y-WH10 GUÍA P ARA SOLUCIONAR PROBLEMAS Si tiene dificultades para hacer funcionar su nuevo ventilador , podría ser a causa del armado , instalación o cableado incorrectos. En algunos casos, estos errores de instalación podrían ser confundidos con defectos.
UL -ES-Parkwa y-WH10 W estinghouse Lighting Corporation 12401 McNult y Road Philadelphia, P A 19154 U.S.A. W estinghouse Lighting Corporation, a W estinghouse Elec tric Corporation licensee is a regis.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Westinghouse UL-ES-Parkway-WH10 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Westinghouse UL-ES-Parkway-WH10 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Westinghouse UL-ES-Parkway-WH10 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Westinghouse UL-ES-Parkway-WH10 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Westinghouse UL-ES-Parkway-WH10, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Westinghouse UL-ES-Parkway-WH10.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Westinghouse UL-ES-Parkway-WH10. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Westinghouse UL-ES-Parkway-WH10 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.