Manuale d’uso / di manutenzione del prodotto ESP45 del fabbricante Wayne
Vai alla pagina of 24
© 2010 WA YNE Pumps 353502-001 3/10 24-V olt Backup Sump Pump OPERA TING INSTRUCTIONS AND P AR TS MANUAL PLEASE READ AND SA VE THESE INSTRUCTIONS. READ CAREFULL Y BEFORE A TTEMPTING TO ASSEMBLE, INST ALL, OPERA TE OR MAINT AIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMA TION.
2 Operating Instructions and Parts Manual www .waynepumps.com A ground fault cir cuit interrupter is required. This pump must only be used to pump clear water . This pump is not designed to handle effl uent, salt water , brine, laundry discharge or any other application which may contain caustic chemicals and/or foreign materials.
3 Model ESP45 www .waynepumps.com PUMP INST ALLA TION Installation of this unit may take several hours. Before disabling your main pump, have ready an appr opriate means of evacuating the sump. 1. T urn power to main pump off. 2. Pump must be installed using 11/4” or 11/2” rigid PVC piping.
4 Operating Instructions and Parts Manual www .waynepumps.com W ear safety goggles when connecting batteries. Battery connections should be made in a well-ventilated area. 1. Place battery box within six feet of the sump and a 115 V AC separately fused outlet.
5 Model ESP45 OPERA TION Always disconnect the power source befor e attempting to install, service, relocate or maintain the pump. Never touch sump pump, pump motor , water or discharge piping when pump is connected to electrical power . Never handle a pump or pump motor with wet hands or when standing on wet or damp surface or in water .
6 Operating Instructions and Parts Manual TROUBLESHOOTING CHART Symptom Possible Cause(s) Corrective Action Pump won't run 1. Connections not secure 2. Low or defective battery 3. Float switch stuck 4. Defective or blown fuse 1. Check all connections 2.
7 Model ESP45 www .waynepumps.com FOR REPLACEMENT P ARTS OR TECHNICAL ASSIST ANCE, CALL 1-800-237-0987 Please provide following information: - Model number - Serial number (if any) - Part description and number as shown in parts list Address parts correspondence to: WA YNE Water Systems 101 Production Drive Harrison, OH 45030 U.
8 Operating Instructions and Parts Manual www .waynepumps.com LIMITED WARRANTY For one year from the date of purchase, WA YNE Pumps ("WA YNE") will repair or re place, at its option, for the.
9 Fr © 2010 WA YNE Pumps 353602-001 3/10 MÉMENTO : Gardez votre pr euve datée d‘achat à fin de la garantie ! Joignez-la à ce manuel ou classez-la dans un dossier pour plus de sécurité. Pompe de vidange de secours 24 volts INSTRUCTIONS D'UTILISA TION ET MANUAL DE PIÉCES PLEASE READ AND SAVE THESE INSTRUCTIONS.
Instructions d‘Utilisation et Manual de Pièces 10 Fr Un interrup-teur pour protéger contr e un défaut de mise à la terre (DDFT) est exigé. Cette pompe est conçue pour le pompage de l’eau claire seulement.
Modèle ESP45 11 Fr • Le CB/AC est conçu seulement pour la pompe de WA YNE Water Systems, il NE doit P AS être utilisé à toutes autres fins. LE SYSTÈME P ASSERA À L'ALARME SI: • On entend un bip d'alarme si le moteur de la pompe fonctionne.
Instructions d‘Utilisation et Manual de Pièces 12 Fr minimum car cela réduit l’écoulement de sortie de la pompe. Le tuyau qui sort de la structure de l’édifi ce devrait être en pente vers le bas pour que l’eau ne gèle pas dans le tuyau.
Modèle ESP45 13 Fr T oujours débrancher le c.a. et retir er le fusible de la pompe avant de brancher ou débrancher la batterie. 1. Choisir un emplacement convenable sur le plancher près du puisard, pour placer le boîtier de batterie. S'assurer que le cordon du CB/AC atteigne le courant c.
Instructions d‘Utilisation et Manual de Pièces 14 Fr GUIDE DE DÉP ANNAGE Symptôme Cause(s) Possible(s) Mesures Corr ectives Pompe ne fonctionne pas 1. Raccords ne sont pas sûrs 2. Batterie faible ou défectueuse 3. Interrupteur à fl otteur coincé 4.
Modèle ESP45 15 Fr POUR DES PIÈCES DE RECHANGE, COMPOSER 1-800-237-0987 S’il vous plaìt fournir l’information suivante : - Numéro de modèle - Numéro de série (si applicable) - Description et numéro de pièce d’après la liste de pièces Correspondance : WA YNE Pumps 101 Production Drive Harrison, OH 45030 U.
Instructions d‘Utilisation et Manual de Pièces 16 Fr GARANTIE LIMITÉE For one year from the date of purchase, WA YNE Pumps ("WA YNE") will repair or re place, at its option, for the orig.
17 Sp © 2010 WA YNE Pumps 353602-001 3/10 MÉMENTO : Gardez votre pr euve datée d‘achat à fin de la garantie ! Joignez-la à ce manuel ou classez-la dans un dossier pour plus de sécurité. Bomba de r espaldo para sumider os MANUAL DE INSTRUCCIONES DE OPERACIÓN Y PIEZAS POR F A VOR LEA Y GUARDE EST AS INSTRUCCIONES.
Manual de Instrucciones de Operación y Piezas 18 Sp Esta bomba sólo debe usarse para bombear aguas limpias. Esta bomba no está diseñada para bombear efl uentes, agua salada, salmuera,agua con detergentes o en ningún otro líquido que contenga químicos causticos y/o residuos y partículas.
Modelo ESP45 19 Sp BOMBA: • La bomba se encenderá cuando el interruptor de flotador se eleve. El motor de la bomba continuará funcionando durante 15 segundos después de que baje el flotador . INST ALACIÓN DE BOMBA La instala-ción de esta bomba podría tomarle varias horas.
Manual de Instrucciones de Operación y Piezas 20 Sp MÉTODO 2 Si no es posible lograr una descarga separada y dedicada como en el Método 1, la bomba ESP45 puede conectarse a la tubería de descarga de la bomba que funciona con CA, instalando un conector "Y".
Modelo ESP45 21 Sp ¡Riesgo de choque eléctrico! Use un interruptor de circuito de descarga a tierra (GFCI) para reducir el riesgo de choque eléctrico mortal. Asegúrese de que la conexión a tierra del receptáculo esté graduada para 5 amp. por lo menos.
22 Sp GUÍA DE DIAGNÓSTICO DE A VERÍAS Problema Posible(s) Causa(s) Acción Correctiva La bomba no funciona 1. Conexiones fl ojas 2. Batería baja o defectuosa 3. Interruptor de fl otador atascado 4. Fusible defectuoso o quemado 1. Revise todas las conexiones 2.
Modelo ESP45 23 Sp N°. de Ref. Descripción Númer o de pieza Ctd. 1 Bomba 06710 1 2 PS/BC (suministro de energía/carga- dor de batería) 30260-002 1 3 Impulsor 29884-001 1 4 Anillo de desgaste 2818.
Manual de Instrucciones de Operación y Piezas GARANTÍA LIMIT ADA Durante un año a partir de la fecha de compra del comprador original, la compañía WA YNE Pumps ("WA YNE") reparará o re.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Wayne ESP45 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Wayne ESP45 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Wayne ESP45 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Wayne ESP45 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Wayne ESP45, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Wayne ESP45.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Wayne ESP45. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Wayne ESP45 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.