888-921-POOL Electronic Chlorine Generator by LDLINE CONTRO LS INC. G www .goldlinecontrols.com A QUA IT E R ®.
IMPORT ANT SAFETY INSTRUCTIONS When using this electrical equipment, basic safety precau- tions should always be followed, including the following: • READ AND FOLLOW ALL INSTRUCTIONS • Disconnect all AC power during installation.
T able of Content s OPERATION OPERATION OPERATION OPERATION OPERATION General General General General General .........................................................................................1 Water Chemistry Water Chemistry Water Chemistry Water Chemistry Water Chemistry .
1 OPERA TION The Aqua Rite ® is an automatic chlorine generation system for pool or spa sanita- tion. The operation requires a low concentration of salt (sodium chloride) in the pool water. These levels are low enough that it normally will not be tasted.
Saturation index The saturation index (Si) relates to the calcium and alkalinity in the water and is an indicator of the pool water "balance". Y our water is properly balanced if the Si is 0 ±.2. If the Si is below -0.2, the water is corrosive and plaster pool walls will be dissolved into the water .
3 Salt Level Use the chart on page 4 to determine how much salt in pounds or (Kgs) need to be added to reach the recommended levels. Use the equations below (measurements are in feet/gallons and meters/liters) if pool size is unknown. The ideal salt level is between 2700-3400 ppm (parts per million) with 3200 ppm being optimal.
4 G al lo ns a n d ( L ite rs ) o f P oo l/S p a wa te r 12,000 14,000 16, 000 18,000 20,000 22, 000 32,000 24,000 34,000 26,000 36,000 28,000 38, 000 30,000 40,000 Cur r en t salt level (450 00) ( 52.
5 POU NDS an d (K g) OF S T ABI LI ZE R ( CY ANU RI C ACI D) N EEDE D FOR 80 PPM G al lo ns a n d (L ite rs ) of P oo l/ S p a wa te r Cur re n t S ta bilizer Level (p p m) 0 ppm 20 ppm 60 ppm 30 ppm .
6 Controls Main Switch Note: When the Aqua Rite ® is being controlled by the optional Jandy AquaLink ® RS, the main switch will not funciton. AUTO : For normal operation, the Main Switch should be left in the AUTO position.
7 "Desired Output %" adjustment knob The "Desired Output %" adjustment knob is located in the lower center of the Aqua Rite control panel. This setting is used to control the amount of chlorine the Aqua Rite generates. Raise this setting to increase chlorine level and lower it to decrease chlorine level.
8 Maint aining the Aqua Rite System To maintain maximum performance, it is recommended that you open and visually inspect the cell every 3 months or after cleaning your filter. The Aqua Rite ® will remind you to do this by flashing the "Inspect Cell" LED after approximately 500 hours of operation.
9 INST ALLA TION Installation must be performed in accordance with Local and NEC codes. Preparing Pool/Spa Water Refer to page 1 for recommended chemical levels.
Plumbing Ensure that the Aqua Rite ® installation does not constitute a cross connection with the local potable water supply. Consult local plumbing codes. The flow switch and cell should be plumbed in the return line to the pool/spa. The preferred installation is after (downstream) all the pool equipment (filter, heater, solar, etc.
11 Wiring Power must be shut off at the circuit breaker before performing any wiring. Be sure to follow Local and NEC electrical codes. To provide safe operation, the Aqua Rite ® must be properly grounded and bonded. Input Power For stand alone operation: Wire the Aqua Rite to the LOAD SIDE of the filter pump timer.
12 Input Power for use with Jandy AquaLink ® RS: Wire the AquaRite ® DIRECTLY to 120/240VAC power (not through timer or re- lay). Optional Jandy AquaLink RS: The Jandy AquaLink RS and Aqua Rite use a 4 wire connection to communicate and can be wired up to 500' apart.
13 T roubleshooting Visit www.goldlinecontrols.com for helpful information on operation, maintenance and troubleshooting your Aqua Rite ® Electronic Chlorine Generator. You may also call for technical assistance at 888-921-POOL. Technicians at the factory are avail- able from 8:00 AM to 8:00 PM Eastern Standard Time, Monday through Friday.
14 4. "Low Salt" LED illuminated or flashing Check salt level in pool/spa. If salt level is low, add salt according to chart on page 4. Before adding large quantities of salt, it is advisable to have your salt level professionally checked. 5.
15 Aqua Rite ® & Aqua T rol ® Limited W arranty This warranty statement is applicable to all Aqua Rite and Aqua T r ol units with product date codes of January 1, 2002 and after, and supersedes all warranty statements dated prior to January 1, 2002.
16 5. Problems resulting from installing less than one Aqua Rite unit per 40,000 gallons (25,000 gallons commercial/public pools) or one Aqua Trol unit per 18,000 gallons of pool water.
Questions? Refer to www.goldlinecontrols.com for latest manual revisions, additional information and helpful service. Or, you may visit your local Authorized Aqua Rite Dealer or call 888-921- POOL (7665) for assistance.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Waterpik Technologies Aqua Rite Electronic Chlorine Generator è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Waterpik Technologies Aqua Rite Electronic Chlorine Generator - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Waterpik Technologies Aqua Rite Electronic Chlorine Generator imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Waterpik Technologies Aqua Rite Electronic Chlorine Generator ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Waterpik Technologies Aqua Rite Electronic Chlorine Generator, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Waterpik Technologies Aqua Rite Electronic Chlorine Generator.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Waterpik Technologies Aqua Rite Electronic Chlorine Generator. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Waterpik Technologies Aqua Rite Electronic Chlorine Generator insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.