For your records The serial number of your UPS is on the rear panel. You should note the serial number in the space provided below. Retain this booklet as a permanent record of your purchase to aid in identification in the ev ent of theft or loss. Model No: Serial No.
LIMITED WARRANTY What the warranty covers: We warrant this product to be free from defec ts in material and workmanship during the warranty period. If a product proves to be defecti ve in material or workmanship during the warranty period, we w ill at our sole option r epair or replace the product with a like product.
Limitation of implied warranties: THERE ARE NO WARRANTIES, EXPRESS OR IMPLIED, WHICH EXTEND BEYOND THE DESCRIPTION CONTAINED HEREIN INCLUDING THE IMPLIED WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Exclusion of damages: OUR LIABILITY IS LIMITED TO THE COST OF REPAIR OR REPLACEMENT OF THE PRODUCT.
Life Support: We do not recommend the use of our UPS produc ts for life support equipment or direct care where failure of a UPS product could cause failu re of, or diminished effectiveness of the life support equipment or patient care.
.
VS375C/VS575C 1 IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS ! THIS MANUAL CONTAINS IMPORTANT SAFETY INSTRUCTIONS. KEEP THIS MANUAL HANDY FOR REFERENCE. ♦ CAUTION: A BATTERY CAN PRESENT A RISK OF ELECTRICAL SHOCK, BURNS FROM HIGH SHORT-CIRCUIT CURRENT, FIRE OR EXPLOSION FROM VENTED GASES.
2 VS375C/VS575C ♦ CAUTION: ! THE UPS CONTAINS VOLTAGES WHICH ARE POTENTIALLY HAZARDOUS. ALL REPAIRS SHOULD BE PERFORMED BY QUALIFIED SERVICE PERSONNEL. THE UPS HAS ITS OWN INTERNAL ENERGY SOURCE (BATTERY). THE OUTPUT RECEPTACLES MAY BE LIVE EVEN WHEN THE UPS IS NOT CONNECTED TO AN AC SUPPLY.
VS375C/VS575C 3 FEDERAL COMMUNICATIONS COMMISSION (FCC) WARNING: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protecti on against harmful interference in a residential installation.
4 VS375C/VS575C TABLE OF CONTENTS 1. INTRODUCTION 1.1 Overview 5 1.2 Frequency Auto-Selection 5 1.3 User Replaceable Battery Design 5 1.4 Over Voltage and Under Voltage Protection 6 1.5 Schedule Shutdown & Startup 6 1.6 Data-Line Surge Protection 6 2.
VS375C/VS575C 5 1. INTRODUCTION 1.1 Overview The Value Series of Uninterruptible Power Systems ( UPS ) was designed to prevent spikes, transients and blackouts from reac hing your sensitive equipment. Your equipment may include such items as comput ers and computerized instruments to telecommunication systems.
6 VS375C/VS575C 1.4 Over Voltag e an d Under Voltage Protectio n The UPS will switch to backup mode and provide the power from its internal battery w hen the input line voltage is too low or too high.
VS375C/VS575C 7 2. UPS CONTROLS 2.1 External Views 2.2 Power On/Off/Test/Silence Button: The On/Off/Test/Silence Butt on has four functions: 1. When the UPS is off and AC power is present, press this button for more than 3 seconds to turn on the UPS. The UPS can be turned on even when AC power is not present.
8 VS375C/VS575C AC Mode When this Green LED is lit, the UPS is in normal mode, and providing power to your equipment. The UPS will continue to filter and provide surge protection. Battery Mode When this Yellow LED is lit, the UPS is providing pow er from its battery.
VS375C/VS575C 9 3. INSTALLATION AND OPERATION Before installation, please read and understand the following instructions: 3.1 Unpacking and Insp ectio n Examine the packing carton for damage and accessory in the box. Notify the carrier immediately if damage is observed.
10 VS375C/VS575C View So nic G8 10 120V 2.7A 50 / 60 Hz SN: Q771515388 Computer Co Pent ium Pro 200MHz 120V 2.0A 50/60 Hz SN: 123456 3. Multiply the voltage and current of each piece of equipment ( VA requirements ); for example, 120V x 2.7A = 324VA, 120V x 2.
VS375C/VS575C 11 3.5 Connecting Your Equipment to the UPS 1. For all UPS models except the 2x0V ve rsions: connect the power cord(s) of your computer equipment to the output receptacle(s) of the UPS.
12 VS375C/VS575C Note: Backup all unsaved files before you perform the following functional test. 3. To test the backup function, you may unplug the pow er cord of the UPS. During this test, observe that your equipment operates properly and w ithout interruption.
VS375C/VS575C 13 4. SPECIFICATIONS 4.1 Electrical Specifications Product Name Frequency (Hz) Voltage (V) Capacity VA / W 100 / 110 / 120 VS375C 50/60 220 / 230 / 240 375VA / 225W 100 / 110 / 120 VS575.
14 VS375C/VS575C Audible A larm: Battery discharge at power failure Beep every 4 seconds Battery approaches final discharge Beep every second Overload Continuous buzzer 4.2 Mechanical Sp ecificatio ns: Product Name Dimensions Weight (Kg) W × D × H ( mm ) Net Gross VS375C 200*77*175 2.
VS375C/VS575C 15 5. TROUBLESHOOTING If the UPS fails to operate properly, please review the following steps before calling the repair center: 1. Is the UPS plugged into a proper working outlet? 2. Is the line voltage within the rating specified? 3. Does the circuit breaker on the rear panel need to be reset? 5.
16 VS375C/VS575C 6. USER REPLACEABLE BATTERY The Batteries inside your UPS should last fr om between 3 to 5 years. If you suspect that the batteries are weak, allow the UPS to c harge the batteries for at least six hours and then test the backup time.
VS375C/VS575C 17 6.2 Battery Replacemen t Pro cedure for VS375C/ VS575C Changing the batteries in your UPS is a sa fe and easy procedure. Since the battery is isolated from the AC input you may leave your UPS and computer or other equipment on during the following procedure.
18 VS375C/VS575C Fuse Replacement Procedure 1. Use a slotted screwdriver to take out the fuse socket. 2. Take out the broken fuse from the fuse socket. 3. Throw away the broken fuse. 4. Use the slotted screwdriver to push out the spare fuse. 5.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il ViewSonic VS575C è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del ViewSonic VS575C - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso ViewSonic VS575C imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul ViewSonic VS575C ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il ViewSonic VS575C, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del ViewSonic VS575C.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il ViewSonic VS575C. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo ViewSonic VS575C insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.