Manuale d’uso / di manutenzione del prodotto R18CFL del fabbricante Vermont Casting
Vai alla pagina of 14
— Do not store gasoline or other flammable vapors or liquids near this or any other appliance. — WHA T T O DO IF Y OU SMELL GAS • Do not try to light any appliance. • Do not touch an y electrical switch; do not use any phone in y our building.
2 20003889 Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Read these directions thoroughly before installation. For assistance or additional infor- mation, consult your gas log dealer , qualified installer , service agency or gas supplier .
20003889 3 The Logsets have been designed and tested to operate safely when installed according to the installation instructions contained in this manual. Read all instructions before starting the installation. • The logset should be inspected before use and at least annually thereafter .
4 20003889 CA UTION: If you answered “NO” to any item, or have any questions regarding your installation, please contact your dealer/distributor for assistance. Are you burning Natural Gas? If you have Propane Gas, you need to purchase a factory authorized safety pilot kit (see below).
20003889 5 This Damper Stop is designed to work on all CFM Specialty Home Products BR, BC, SR, SC, TF and TL series fireplaces. For all other fireplaces, refer to Page 6. When installing a decorative gas appliance in a fireplace, some local codes require this Damper Stop to be used so the Damper will not close completely .
6 20003889 The Damper Stop provided keeps your damper from accidentally closing during operation of your set. This Damper Stop must be installed onto your Damper at all times . NOTE: The damper clamp is designed to hold the damper plate open 3 inches.
20003889 7 Leak T est Pr ocedures Create a mixture of equal parts soap and water . Apply to all the joints of the pipe fittings from the gas supply pipe to the burner . T urn on the gas supply valve for no longer than 3-5 seconds. If bubbles appear in the soap solution applied to the joints, there is a leak.
8 20003889 1. Place the Elevated Grate Steps onto the back of the Grate and attach the Fettel to front of Grate as shown in Figure 7. 2. Place the Grate over the Burner Pan so the front legs of the Grate are 1” behind the front edge of the Pan, as shown in Figure 8.
20003889 9 1. T urn the gas shut-of f valve to OFF . 2. W ait five (5) minutes to clear out any gas. If you then smell gas STOP! Follow the safety information above. If you don’t smell gas, go on to the next step. 3. Light a match and lay it on top of the pan material, about 2” from the end of the supply side of the pan.
10 20003889 Tr oub leshooting Log Set is Smoking/Sooting Excessively It is natural and unavoidable for vented gas log sets to produce moderate levels of carbon (soot) where flame contacts the logs.
20003889 11 8 11 7 5 4 2 3 17 13 18 16 14 19 10 12 15 9 6 1 a b c d e f g h CFM Specialty Home Products reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. R18 / 24 / 30CFL V ented Gas Logs 1.
12 20003889 R18 / 24 / 30CFL V ented Gas Logs (continued) Ref. Description R18CFL R24CFL R30CFL 11 . Cast Front Grate w/Clips CIGF18 CIGF24 CIGF30 12. Grate 20000924 20000925 20000926 13. Grate Step 20000955 20000955 20000955 14. Pan & Extension Assembly 20003840 20003841 20003842 15.
20003889 13 W ARRANTIES OF MERCHANT ABILITY OR FITNESS FOR A P ARTICULAR PURPOSE), ALL OF WHICH ARE HEREBY EXPRESSL Y INCLUDED. IN NO EVENT SHALL ANY IMPLIED W ARRANTY PRESCRIBED BY LA W (NOTWITHST ANDING THE FOREGOING EX- PRESS EXCLUSION) REMAIN IN EFFECT AFTER EXPIRA TIONS OF THE W ARRANTIES SET FORTH IN P ARAGRAPHS A AND B.
410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 • 905-670-7777 www .majesticproducts.com • www.vermontcastings.com CFM Specialty Home Pr oducts.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Vermont Casting R18CFL è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Vermont Casting R18CFL - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Vermont Casting R18CFL imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Vermont Casting R18CFL ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Vermont Casting R18CFL, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Vermont Casting R18CFL.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Vermont Casting R18CFL. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Vermont Casting R18CFL insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.