Manuale d’uso / di manutenzione del prodotto LHER20 del fabbricante Vermont Casting
Vai alla pagina of 28
10005360 5/06 Rev . 5 Natural V ent Insert Models: LHER20 LHEC20 LHER30 LHEC30 D E S I G N C E R T I F I E D CERTIFIED DO NOT ST ORE OR USE GASOLINE OR OTHER FLAMMABLE V APORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE. WHA T TO DO IF YOU SMELL GAS: • Do not try to light any appliance.
2 10005360 LHE Ser ie s N atur al V ent I nser t T able of Contents PLEASE READ THE INST ALLA TION & OPERA TING INSTRUCTIONS BEFORE USING THIS APPLIANCE. Thank you and congratulations on your purchase of a CFM Corporation fireplace insert. IMPORT ANT - Read all instructions and warnings carefully before starting installation.
3 10005360 LHE Ser ie s N atur al V ent I nser t This gas appliance should be installed by a qualified installer in accordance with local building codes and with current CSA- B149.1 Installation codes for Gas Burning Appliances and Equipment. FOR U.S.
4 10005360 LHE Ser ie s N atur al V ent I nser t N O P E M F 5360 LHE ac spces 5/03 U S R Q V T FP1248 Minimum fireplace opening 1/03 Q - Fireplace opening height R - Fireplace opening width S .
5 10005360 LHE Ser ie s N atur al V ent I nser t When the unit is installed into a woodburning fireplace, the minimum distance the mantel can be placed above the fireplace is governed by local building codes appli- cable to woodburning fireplaces. Consult local authori- ties having jurisdiction for these clearances.
6 10005360 LHE Ser ie s N atur al V ent I nser t Natural LP Minimum Inlet Pressure 5.5" W . C . 1 1.0" W . C . Maximum Inlet Pressure 14.0" W . C . 14.0" W . C . Manifold Pressure 3.5" W . C . 10.0" W . C . Gas Inlet & Manifold Pressures Do not use this appliance if any part of it has been under water .
7 10005360 LHE Ser ie s N atur al V ent I nser t FP297 INST A VENT FREE R MODEL GAS SUPPL Y 8/24/96 1/2" Gas Supply 1/2" x 3/8" Shut Off V alve 3/8" Nipple 3/8" Union FP297 Fig.
8 10005360 LHE Ser ie s N atur al V ent I nser t Installer must attach red warning plate with screws supplied with the gas fireplace insert to the inside of the firebox of the fireplace into which the gas fireplace insert is installed.
9 10005360 LHE Ser ie s N atur al V ent I nser t Zero clearance kit minimum clearance to combustibles materials is 1" (25 mm) for B V ent (use of single wall vent is not allowed.) As with any natural drafted appliances, the vent cap must always extend a minimum of 2' (610 mm) above any structure within a 10' (3 m) horizontal plane.
10 10005360 LHE Ser ie s N atur al V ent I nser t Ceramic Refractory Installation 1. Remove front glass. 2. Remove logs from unit. 3. Remove refractory from package. Refractory are fragile and must be handled with care. Where at all possible, two hands should be used when handling.
1 1 10005360 LHE Ser ie s N atur al V ent I nser t Operating Instructions General Glass Information Only ceramic glass approved by CFM Cor- poration may be used for replacement on this unit. 1. The use of substitute glass will void all product warranties.
12 10005360 LHE Ser ie s N atur al V ent I nser t First Firing Upon completing the gas line connec- tion, a small amount of air will be in the lines. When first lighting unit with pilot light, it will take a few minutes to purge themselves of this air .
13 10005360 LHE Ser ie s N atur al V ent I nser t F584-703 Honeywell & PSE pilot flames 3/8" - 1/2" SIT Pilot PSE Pilot F584-703 Fig. 22 Correct pilot flame appearance. L O H I Turn counterclockwise to increase flame height.
14 10005360 LHE Ser ie s N atur al V ent I nser t 3. Open control access panel. 4. Push in gas control knob slightly and turn clock- wise to " OFF ". Do not force. 5. Close control access panel. 1. ST OP! Read the safety information above. 2.
15 10005360 LHE Ser ie s N atur al V ent I nser t W ARNING: Before doing any gas control service work, remove glass front. SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION 1. Spark ignitor will not light A. Defective or misaligned Using a match, light pilot.
16 10005360 LHE Ser ie s N atur al V ent I nser t Gas Supply On Supply Line Hooked Up Shutoff Valve Open NO NO NO NO Lockout Has Engaged. Wait 60 Seconds And Try Again. For Spark At Electrode While Depressing Piezo — 1/8" Gap To Pilot Hood Needed.
17 10005360 LHE Ser ie s N atur al V ent I nser t Instructions for RF C om fo rt C on tr o l Va lv e The Comfort Control V alve allows remote control of temperature, fan and flame appearance. NOTE: The antenna should hang in free air away from grounded metal.
18 10005360 LHE Ser ie s N atur al V ent I nser t Delay Timer Mode The shut off delay timer has a maximum of 2 hours and a minimum of zero minutes. T o change the timer level, press the time key followed by an arrow key . Pushing the key once will change the timer by 10 minutes.
19 10005360 LHE Ser ie s N atur al V ent I nser t LED Count Service Action 8 Replace valve 7 Confirm stepper motor connection exists 5 Confirm fan connection exists and works 4 Confirm gas type; jumper in place 3 Replace thermopiles 2 T urn fan ON NOTE: Some keys are not active.
20 10005360 LHE Ser ie s N atur al V ent I nser t Light pilot burner Set manual switch to local or remote Release pilotstat knob T urn pilotstat knob from PILOT to ON If manual switch is set to LOCAL,.
21 10005360 LHE Ser ie s N atur al V ent I nser t Maintenance Burner and Burner Compartment It is important to keep the burner and the burner compartment clean. At least once per year the logs and lava rock/ember material should be removed and the burner compartment vacuumed and wiped out.
22 10005360 LHE Ser ie s N atur al V ent I nser t LHER20/LHEC20 1a 1d 1b 1e LHER30/LHEC30 1a 1d 1c 1e 1b 3 2 4 5 6a/b 7a/b 9 a/b 8a/b 19 14 16 18 10a/b 18 17 1 1a/b 12a/b 13a/b 15 20 .
23 10005360 LHE Ser ie s N atur al V ent I nser t LHE Series (continued) Ref. Description LHER20 LHEC20 LHER30 LHEC30 1. Log Set Complete 10005332 10005332 10004866 10004866 1a. Log Rear Left 10005333 (JR7) 10005333 (JR7) 10004874 (KR22) 10004874 (KR22) 1b.
24 10005360 LHE Ser ie s N atur al V ent I nser t Ref. Description LHER20 LHEC20 LHER30 LHEC30 LHE Series (continued) 37. Remote Switch (for RN or RP Units) 53606 53606 53606 53606 38. Remote Wire Harness w/T erminals (for RN or RP Units) 10002582 10002582 10002582 10002582 39.
25 10005360 LHE Ser ie s N atur al V ent I nser t Optional Accessories Remote Controls Optional remote control units are available to control different functions of the appliance.
26 10005360 LHE Ser ie s N atur al V ent I nser t Modification Instructions of EP28-5 Series Fireplace Upgrading to LHEC20 or LHER20 Natural V ent Insert W ARNING: Y ou must turn off gas supply to fireplace. 1. Remove the upper and lower trims. 2. Remove the doors and mesh firescreen, if installed.
27 10005360 LHE Ser ie s N atur al V ent I nser t BASIC W ARRANTY CFM Corporation (hereinafter referred to collectively as the Company) warrants that your new V ermont Castings or Majestic Gas Firepla.
Efficiency Ratings Model EnerGuide Ratings Steady State (%) D.O.E. Fireplace Efficiency (%) Fan-OFF Fan-ON (AFUE%) LHEC20RN 51.2 71 75 60 LHEC20RP 51.2 72 76 60 LHEC20RFN 51.2 71 75 60 LHEC20RFP 51.2 72 76 60 LHER20RN 51.0 69 N/A 59 LHER20RP 51.0 70 N/A 59 LHEC30RN 48.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Vermont Casting LHER20 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Vermont Casting LHER20 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Vermont Casting LHER20 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Vermont Casting LHER20 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Vermont Casting LHER20, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Vermont Casting LHER20.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Vermont Casting LHER20. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Vermont Casting LHER20 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.