FP596A 1/14/99 Homeowner ’ s Installation and Operating Manual Builder Direct V ent DO NOT ST ORE OR USE GASOLINE OR OTHER FLAMMABLE V APORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE. WHA T TO DO IF YOU SMELL GAS: • Do not try to light any appliance.
2 DVBR Series Direct Vent Gas Fireplace 20000584 Installation & Operating Instructions General Information .................................................................................................................... 3 Fireplace Dimensions .
3 DVBR Series Direct Vent Gas Fireplace 20000584 Installation Instructions This gas appliance should be installed by a qualified installer in accordance with local building codes and with current CSA- B149.1 Installation codes for Gas Burning Appliances and Equipment.
4 DVBR Series Direct Vent Gas Fireplace 20000584 584 Specs - top vent 2/14/02 djt P - Rough Opening Width Rough Opening Height Rough Opening Depth S S T 5/8” (16 mm) R Q G H I M N 5/8” (16 mm) E D.
5 DVBR Series Direct Vent Gas Fireplace 20000584 Ref. DVBR36 DVBR42 A 40” (1016 mm) 46” (1 168 mm) B 36” (614 mm) 36” (914 mm) C 36” (914 mm) 42” (1067 mm) D 23 ¹⁄₄ ” (591 mm) 23 ¹.
6 DVBR Series Direct Vent Gas Fireplace 20000584 Clearance to Combustibles Appliance T op ......................................................... 0” (0 mm) Bottom ..................................................... 0” (0 mm) Side .............
7 DVBR Series Direct Vent Gas Fireplace 20000584 Cold climate installation recommendation: When installing this unit against a non- insulated exterior wall or chase, it is mandatory that the outer walls be insulated to conform to applicable insulation codes.
8 DVBR Series Direct Vent Gas Fireplace 20000584 Always check for gas leaks with a mild soap and water solution applied with a brush no larger than 1” (25 mm). Never apply soap and water solution with a spray bottle. Do not use an open flame for leak testing.
9 DVBR Series Direct Vent Gas Fireplace 20000584 Optional T op V ent Application The DVBR36/42 fireplace is shipped as a rear vent unit. If the layout requires a top vent, convert the unit follow- ing the steps below . DVBR36 1. Remove the eight (8) screws securing outer collar adapter to fireplace.
10 DVBR Series Direct Vent Gas Fireplace 20000584 FP1543 remove insulation 1/05 Remove Insulation FP1543 Fig. b Remove and discard insulation. Y our fireplace is approved to be vented either through the side wall, or vertical through the roof.
1 1 DVBR Series Direct Vent Gas Fireplace 20000584 Canadian Installations 1 US Installations 2 V V V V V V V X X X D E B B B C B M B A J K F L VENT TERMINA TION AIR SUPPL Y INLET AREA WHERE TERMINAL IS NOT PERMITTED H I Operable Operable Fixed Closed V B CFM145a DV T ermin Location 5/01/01 Rev .
12 DVBR Series Direct Vent Gas Fireplace 20000584 General Information Assembling V ent Pipes Flex V ent Pipes Before joining the flex vent pipe to the unit, apply a bead of high temperature sealant* (provided) to the 4” pipe exiting the fireplace.
13 DVBR Series Direct Vent Gas Fireplace 20000584 TWL100 T wist Lock Pipe 3/12/99 djt Male End Female End Screw Holes TWL100 Fig. 17 T wist-Lock pipe joints. T wist Lock Pipes When using CFM Corporation twist-lock pipe, it is not necessary to use silicone to seal the twist-lock joints.
14 DVBR Series Direct Vent Gas Fireplace 20000584 Rear W all V ent Installations - T wist Lock Pipe Step 1 Locate and cut the vent opening in the wall. For combustible walls first frame in opening. (Fig. 21) NOTE: When using flex vent, the opening will have to be measured according to the 1” (25 mm) rise in 24” (610 mm) vertical run.
15 DVBR Series Direct Vent Gas Fireplace 20000584 FP1005 Side View V ent T ermination 1/25/00 djt Finished W all V ent T ermination Fig. 23 Side view of final unit location, twist lock pipe. FP1005 These ends should be even These ends screwed to appli- ance 1/ 2" (1 3m m) 12 " ( 30 5m m) FP 147 2 ri se in l eng th 4/ 04 d jt FP1472 Fig.
16 DVBR Series Direct Vent Gas Fireplace 20000584 V584-201 Horizontal Run 2/99 djt 10’ (254cm) 7’ (178cm) 8’ (244cm) A B A + B = 17’ Max. V584-201 Fig. 29 Maximum vent run with elbows. In Figure 28 & 29, dimension A plus B must not be greater than 17’ (5.
17 DVBR Series Direct Vent Gas Fireplace 20000584 V ertical Sidewall Installation T wist Lock Pipe Step 1 Locate vent opening on the wall. It may be necessary to first position the fireplace and measure to obtain hole location. Depending on whether the wall is combustible or noncombustible, cut opening to size.
18 DVBR Series Direct Vent Gas Fireplace 20000584 X X FP1 182 Fig. 34 Horizontal length requirement. Sealing vent pipe and firestop gaps with high tem- perature sealant will restrict cold air being drawn in around fireplace.
19 DVBR Series Direct Vent Gas Fireplace 20000584 Do not back fill around snorkel. A clearance of at least 4” must be main - tained between the snorkel and the soil. If the foundation is recessed, use recess brackets (not supplied) for securing lower portion of the snorkel.
20 DVBR Series Direct Vent Gas Fireplace 20000584 1 2 3 4 1 2 3 4 1 + 2 + 3 + 4 = 270° FP1 179 Fig. 42 Maximum elbow usage. FP1184 T ypical roof/ceiling suppor t apps. FP1 184 T ypical Roof Support Ap- plication T ypical Ceiling Sup - port Application Fig.
21 DVBR Series Direct Vent Gas Fireplace 20000584 Min. 2' (610 mm) FP1 185 Fig. 45 Minimum termination to roof clearance. TWL101a T wist Lock Pipe 2/8/99 djt 3 #5 Sheet Metal Screws per Joint Sealant Storm Collar TWL101a Fig.
22 DVBR Series Direct Vent Gas Fireplace 20000584 584E V enting Components T elescope vent 2/25/99 djt 10/20/99 twist lock 584D V ent Components 90 degree elbow 2/25/99 djt 10/20/99 twist lock 584A ve.
23 DVBR Series Direct Vent Gas Fireplace 20000584 1. T urn off gas. 2. Let the fireplace cool if it has been operating. 3. Remove valve cover . (Fig.47) 4. Release the two (2) clamps at the bottom of the window frame by pulling back on the clamp handles.
24 DVBR Series Direct Vent Gas Fireplace 20000584 1 . Remove front glass. (See “Glass Remov- al” Section, Fig. 48) 2. Remove logs from packaging. As with all plastics — these are not toys and should be kept away from children and infants. 3. Place Right Rear Log onto the two pem studs on the rear log support.
25 DVBR Series Direct Vent Gas Fireplace 20000584 Right Cover Log Center Log Left Cover Log LG391 Fig.
26 DVBR Series Direct Vent Gas Fireplace 20000584 T op logs must be placed properly onto notches. Fig. 57 Correct flame appearance for DVBR36 model. LG389 Fig.
27 DVBR Series Direct Vent Gas Fireplace 20000584 3. Open louvre assembly bottom. 4. Push in gas control knob slightly and turn clock- wise to “OFF”. Do not force. 5. Close control access panel. 1. STOP! Read the safety information above. 2. T urn off all electrical power to the fireplace.
28 DVBR Series Direct Vent Gas Fireplace 20000584 T roubleshooting – Honeywell VS8421 ST ART CHECK Gas Supply On Pilot Lights With Piezo Ignitor • Lockout Has Engaged. W ait 60 Seconds And T ry Again. • For Spark At Electrode While Depressing Piezo 1/8" Gap T o Pilot Hood Needed.
29 DVBR Series Direct Vent Gas Fireplace 20000584 W ARNING: BEFORE DOING ANY GAS CONTROL SERVICE WORK, REMOVE GLASS FRONT . SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION 1. Spark ignitor will not light A. Defective or misaligned Using a match, light pilot.
30 DVBR Series Direct Vent Gas Fireplace 20000584 4. For conver- sion to Natural Gas remove the manifold mounting bracket. Replace the nut and screw removed earlier . Attach the air shut- ter to the burner tube and secure with screw . T ighten screw .
31 DVBR Series Direct Vent Gas Fireplace 20000584 CO103 Gas Conv ersion Air shutter 2/15/99 djt Fig. 63 Remove air shutter from burner pan. Shutter Retaining Screw Burner Pan Air Shutter Front View CO103 Fig.
32 DVBR Series Direct Vent Gas Fireplace 20000584 Burner and Burner Compartment It is important to keep the burner and the burner compartment clean. At least once per year the logs and lava rock/ember material should be removed and the burner compartment vacuumed and wiped out.
33 DVBR Series Direct Vent Gas Fireplace 20000584 1d 1e 1c 1a 1b 1f 1g 1h 1i 1. DVBR36 2 3 4 5 6 7a 7b 10 1 1 12 9 8 14 13 a/b 15 a/b 16 28 29 PILOT ON OFF PILOT ADJ L O H I TPTH TH TP 17a,b 18a/b 25a/b 26 19 20 21 22 23a/b 24 32 33 36 37 38 0584 DVBR parts 2005 1d 1e 1c 1a 1b 1f 1.
34 DVBR Series Direct Vent Gas Fireplace 20000584 DVBR36/42 (continued) Ref. Description DVBR36 DVBR42 2. Lava Rock Package 20000198 20000198 3. Mineral W ool Bagged 51 10184 51 10184 4. Ceramic T ile (Single) 57803 57803 5. Burner Housing with T ile 20008831 20008836 6.
35 DVBR Series Direct Vent Gas Fireplace 20000584 Optional Accessories Optional Fk-12 Fan Hook-up 1. Remove control cover from unit. 2. Remove glass door by rotating latches at bottom corners of door . Refer to Page 23. 3. Remove the 9 screws securing burner to combustion bottom.
36 DVBR Series Direct Vent Gas Fireplace 20000584 H102 rear ceramic suppor t 2/23/99 djt Rear Ceramic Panel Back of Firebox Rear Log Sup- port Burner Fig. 75 Rear ceramic panel placement. H102 Side View Decorative Glass Panels Brilliance Glass Panels are available to enhance the beauty and viewing pleasure of your DVBR fireplace.
37 DVBR Series Direct Vent Gas Fireplace 20000584.
38 DVBR Series Direct Vent Gas Fireplace 20000584.
39 DVBR Series Direct Vent Gas Fireplace 20000584 BASIC W ARRANTY CFM Corporation (hereinafter referred to collectively as the Company) warrants that your new V ermont Castings or Majestic Gas Firepla.
410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 800-668-5323 • www .cfmcorp.com CFM Corporation.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Vermont Casting DVBR36 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Vermont Casting DVBR36 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Vermont Casting DVBR36 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Vermont Casting DVBR36 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Vermont Casting DVBR36, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Vermont Casting DVBR36.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Vermont Casting DVBR36. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Vermont Casting DVBR36 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.