Sav e this manual for future reference. For more information, visit www .desatech.com W ARNING: If the information in this manual is not fol- lowed exactly , a fire or explosion may result causing property damage, personal injury , or loss of life. W ARNING: For use only with a listed gas-fired unvented decorative room heater .
www .desatech.com 105604-01H 2 W ARNING: Improper installation, adjustment, altera- tion, service, or maintenance can cause injury or prop- erty damage. Refer to this manual for correct installation and operational procedures. For assistance or addi- tional information consult a qualified installer , service agency , or the gas supplier .
www .desatech.com 105604-01H 3 SAFETY INFORMA TION WA RNI NG: Th is pro duc t co n- ta ins a nd /or g en era tes c he mic als kn own t o t he St ate o f C al ifo rni a to ca use c an cer o r bir th de fe cts , or ot her re pro duc tiv e h arm .
www .desatech.com 105604-01H 4 5. V ent-free gas log heaters installed in these fireboxes require fresh air ventilation to run properly . See Air for Combustion and V entila- tion, page 6. 6. Do not run firebox • wher e flammab le liqui ds or vap ors are used or stored • under dusty conditions 7.
www .desatech.com 105604-01H 5 12 1 / 2 " 2 3 / 4 " 1 1 / 2 " 9 3 / 4 " 4 5 / 8 " 2 1 / 2 " 6" 32 3 / 16 " 33 11 / 16 " Figure 2 - Firebox Side V iew Gas L.
www .desatech.com 105604-01H 6 AIR FOR COMB USTION AND VENTILA TION W ARNING: This firebox shall no t b e i nst all ed in a co nfin ed spac e or unusu ally tight con stru c - tion unless provisions are provid- ed for adequate combustion and ventilation air .
www .desatech.com 105604-01H 7 DETERMINING FRESH-AIR FLOW FOR HEA TER LOCA TION Determining if Y ou Have a Confined or Unconfined Space Use this work sheet to determine if you have a confi ned or unco nfine d s pace .
www .desatech.com 105604-01H 8 AIR FOR COMB USTION AND VENTILA TION Continued VENTILA TION AIR V entilation Air From Inside Building This fresh air would come from an adjoining un - confined space.
www .desatech.com 105604-01H 9 IMPORT ANT : V ent-free gas log heaters add moisture to the air . Although this is beneficial, installing firebox in rooms without enough ventilation air may cause mildew to form from too much moisture. See Air for Combustion and V entilation , page 6.
www .desatech.com 105604-01H 10 INST ALLING BLOWER ACCESSOR Y (Model FB32CA only) Y ou may install blower accessory GA3700 with conventional installation (below) or with built-in installation (page 11) with models FB32CA and NLFB32C only .
www .desatech.com 105604-01H 1 1 7. Plug in blower power cord. a. If your firebox is installed as a freesta nding unit, determine whether the power cord will exit the left side or the right side of the firebox. Install 1 plastic bushing provided into the 1 1 / 2 " hole in the floor support on the exit side.
www .desatech.com 105604-01H 12 INST ALLING LOG HEA TER IN FIREBOX CAUTI ON: Do not rem ove the da ta p lat es att ache d to the hea te r base assembly . The data plates contain important warranty and safety information. CAUTION: Do not pick up log base assembly by burners.
www .desatech.com 105604-01H 13 Electrical Outlet INST ALLING FIREPLACE SCREEN 1. Insert each rod through nine rings located at top of screen. 2. Insert first rod into rear hole in left side of firebox. Fasten rod to rear hole near center of firebox using black shoulder screw .
www .desatech.com 105604-01H 14 7. Brea k off nail ing flang es (s ee Fi gure 19) w ith hamm er or p lier s. IMPORT ANT : When installing Brass T rim Kit , s ee i nstr uct ion s in clu ded wit h ma nte l accessory . 8. Place cardboard or other protective material on top of hearth base.
www .desatech.com 105604-01H 15 2. Inst all ga s pip ing to firebo x loca tion. T his installation includes an approved flexible gas line (if allowed by local codes) after the manual shutoff valve. The flexible gas line must be the last item installed on the gas pip - ing.
www .desatech.com 105604-01H 16 ACCESSORIES Purchase these firebox accessories from your local dealer . If they can not supply these accessories, call DESA Heating Productsʼ Sales Department at 1-866-672-6040 for information. Y ou can also write to the address listed on the back page of this manual.
www .desatech.com 105604-01H 17 ACCESSORIES Continued HARDWOOD CABINET HEARTH BASE GC3333F Series - W alnut Finished GC3334U Series - Unfinished GC3335F Series - Oak V eneer Finished GM3004W Series - Off White The cabinet hearth base creates a handsome riser for the firebox (cannot be used with corner mantel or face mantel).
www .desatech.com 105604-01H 18 ILL USTRA TED P ARTS BREAKDOWN MODELS FB32NCA AND NLFB32NC 5 14 16 16 16 13 15 17 17 17 16 6 1 7 16 18 10 8 20 12 19 9 4* 2* 3* 2* 16 1 1 18.
www .desatech.com 105604-01H 19 KEY P ART NUMBER NO. FB32NCA NLFB32NC DESCRIPTION QTY . 1 101872-03 101872-03 Firebox T op 1 2 101889-01 * Firebrick Retainer 3 3 101929-04 * Rear Firebrick 1 4 101932-.
www .desatech.com 105604-01H 20 ILL USTRA TED P ARTS BREAKDOWN MODELS FB32CA AND NLFB32C 5 16 16 15 16 17 22 6 1 16 7 16 14 21 13 18 10 8 20 12 19 9 4* 2* 3* 2* 16 1 1 18 18.
www .desatech.com 105604-01H 21 P ARTS LIST This list contains replaceable parts used in your firebox. When ordering parts, follow the instructions listed under Replacement Parts on page 15 of this manual. KEY P ART NUMBER NO. FB32CA NLFB32C DESCRIPTION QTY .
www .desatech.com 105604-01H 22 NO TES __________________________________________________________ __________________________________________________________ ___________________________________________.
www .desatech.com 105604-01H 23 NO TES __________________________________________________________ __________________________________________________________ ___________________________________________.
2701 Industrial Drive P .O. Box 90004 Bowling Green, KY 42102-9004 www .desatech.com 105604-01 Rev . H 07/04 NOT A UPC WARRANTY INFORMA TION KEEP THIS WARRANTY Model Serial No. Date Purchased Always specify model and serial numbers when communicating with the factory .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Vanguard Heating FB32NCA è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Vanguard Heating FB32NCA - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Vanguard Heating FB32NCA imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Vanguard Heating FB32NCA ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Vanguard Heating FB32NCA, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Vanguard Heating FB32NCA.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Vanguard Heating FB32NCA. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Vanguard Heating FB32NCA insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.