Manuale d’uso / di manutenzione del prodotto 24" del fabbricante Vanguard Heating
Vai alla pagina of 26
UNVENTED (VENT -FREE) PROP ANE/LP GAS LOG HEA TER V ariable Manually-Contr olled Models Also Design-Certified As V ented Decorative Appliances ® Save this manual for future reference. This appliance may be installed in an aftermarket* manufactured (mobile) home, where not prohibited by state or local codes.
2 104309 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX ® SAFETY INFORMA TION DANGER: Carbon monoxide poisoning may lead to death! Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning re- semble the flu, with headaches, dizziness, or nausea.
3 104309 OWNER’S MANUAL PRODUCT IDENTIFICA TION LOCAL CODES Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code ANS Z223.1 , also known as NFPA 54*. *Available from: American National Standards Institute, Inc.
4 104309 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX ® PROVIDING ADEQUATE VENTILATION The following ar e excerpts from National Fuel Gas Code. NFPA 54/ANS Z223.1, Sec- tion 5.3, Air for Combustion and Ventilation. All spaces in homes fall into one of the three following ventilation classifications: 1.
5 104309 OWNER’S MANUAL DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION Determining if You Have a Confined or Unconfined Space Use this work sheet to determine if you have a confined or unconfined space.
6 104309 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX ® AIR FOR COMBUSTION AND VENTILA TION Continued VENTILATION AIR Ventilation Air From Inside Building This fresh air would come from an adjoining unconfined space.
7 104309 OWNER’S MANUAL LOG SIZING REQUIREMENTS Log Minimum Firebox Size Height Depth Front Rear * Width Width 18" 17" 14" 24" 20" 24" 17" 14" 28" 21&quo.
8 104309 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX ® INST ALLA TION Continued Minimum Noncombustible Material Clearances If Not Using Mantel Note: If using a mantel, proceed to If Using Mantel . If not using a mantel, follow the information below.
9 104309 OWNER’S MANUAL Figure 7 - Minimum Mantel Clearances When Using Hood INST ALLA TION Continued Figure 6 - Minimum Mantel Clearances Without Using Hood MANTEL CLEARANCES In addition to meeting noncombustible mate- rial clearances, you must also meet required clearances between fireplace opening and mantel shelf.
10 104309 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX ® INST ALLA TION Continued INSTALLING HEATER BASE ASSEMBLY WARNING: If installing in a sunken fireplace, special care is needed. You must raise the fire- place floor to allow access to heater control panel.
11 104309 OWNER’S MANUAL CONNECTING TO GAS SUPPLY NOTICE: A qualified service per- son must connect heater to gas supply. Follow all local codes. CAUTION: Never connect heater directly to the propane sup- ply. This heater requires an exter- nal regulator (not supplied).
12 104309 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX ® ON POSITION OFF POSITION Figure 15 - Manual Shutoff Valve Open Closed Manual Shutoff Valve Figure 16 - Checking Gas Joints WARNING: Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints.
13 104309 OWNER’S MANUAL INST ALLA TION Continued WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury. INSTALLING LOGS It is very important to install the logs exactly as instructed.
14 104309 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX ® 1. STOP! Read the safety inf ormation, column 1. 2. Make sur e manual shutoff valve is fully open.
15 104309 OWNER’S MANUAL Figure 20- Pilot Ignitor Electrode Pilot Burner 8. Keep contr ol knob pressed in f or 30 seconds after lighting pilot. After 30 seconds, release contr ol knob . • If control knob does not pop out when released, contact a qualif ied service person or gas supplier f or repairs.
16 104309 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX ® IMPORT ANT: This remote control has been specially engineered to take an air temperature sample e v- ery 5.5 minutes in the A UTO mode. It will not respond immediately to the temperature setting being turned up or do wn.
17 104309 OWNER’S MANUAL TROUBLESHOOTING WARNING: Turn off heater and let cool before servicing. Only a qualified service person should service and repair heater. CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/ pilot unit.
18 104309 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX ® OBSERVED PROBLEM Burner does not light after ODS/pilot is lit Delayed ignition burner Burner backfiring during combustion Slight s.
19 104309 OWNER’S MANUAL TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone.
20 104309 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX ® SPECIFICA TIONS Golden Oak Golden Oak 18" Remote 24”,30”,and 36" Ready Remote Ready Btu (Variable) 16,000/30,000 20,000/39,000 Type Gas Propane Only Propane Only Ignition Piezo Piezo Pressure Manifold 8.
21 104309 OWNER’S MANUAL CLEANING AND MAINTENANCE WARNING: Turn off heater and let cool before cleaning. CAUTION: You must keep control areas, burner, and circu- lating air passageways of heater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a quali- fied service person.
22 104309 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX ® ILLUSTRA TED PA R T S BREAKDOWN FLAME-MAX™ GOLDEN OAK LOG MODELS VYD18PR, VYD24PR, VYD30PR, AND VYD36PR 4 13 13 14 22 13 8 18 7 .
23 104309 OWNER’S MANUAL P ARTS LIST VYD18PR, VYD24PR, VYD30PR, AND VYD36PR This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 20 of this manual. KEY PART NUMBER FOR NO.
24 104309 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX ® ACCESSORIES Purchase these heater accessories from your local dealer. If they can not supply these accessories, call DESA International’s Parts Department at 1-800-972-7879 for referral information.
25 104309 OWNER’S MANUAL NOTES _______________________________________________________________________________________________ _______________________________________________________________________.
KEEP THIS WARRANTY W ARRANTY INFORMA TION Always specify model and serial numbers when communicating with the factory. We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Vanguard Heating 24" è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Vanguard Heating 24" - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Vanguard Heating 24" imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Vanguard Heating 24" ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Vanguard Heating 24", ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Vanguard Heating 24".
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Vanguard Heating 24". Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Vanguard Heating 24" insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.