Manuale d’uso / di manutenzione del prodotto UT362 del fabbricante Uni-T
Vai alla pagina of 30
1 UT361/UT362 OPERA TING MANUAL T able of Contents Title Page Overview Unpacking Inspection Rules For Safety Operation The Anemoscope Structure Display Symbols Setting Up The Anemoscopes Using The Ane.
2 UT361/UT362 OPERA TING MANUAL Overview Model UT361 and UT362 are an anemoscopes with high accurate sensitive resistance (NTC) as testing point. For fan axis, it uses a high durable ruby shaft in order to provide the accurate and stable measurement.
3 UT361/UT362 OPERA TING MANUAL Item 1 2 3 4 Description English Operating Manual USB Interface Cable (UT362) only Software (UT362) only 9 V Battery Software Qty 1 piece 1 piece 1 piece 1 piece W arning T o avoid electric shock or personal injury , read the "Rules for Safe Operation" carefully before using the Anemoscope.
4 UT361/UT362 OPERA TING MANUAL In the event you find any missing or damage, please contact your dealer immediately . In this manual, a W arning identifies conditions and actions that pose hazards to the user , or may damage the anemoscopes or the equipment under test.
5 UT361/UT362 OPERA TING MANUAL T o avoid possible electric shock or personal injury and to avoid possible damage to the anemoscopes or to the equipment under test, adhere to the following rules Do no.
6 UT361/UT362 OPERA TING MANUAL Use the specific authorized replacement part if you need to repair the anemoscopes Do not use the anemoscopes if the opening the housing cover Note the battery " + " and " - "pole when battery insert.
UT361/UT362 OPERA TING MANUAL The Anemoscope Structure (see figure 1) Fan Wind Speed Indicator Handle Secondary Display Primary Display Power Button Operational Button Main Unit 1 2 3 4 5 7 6 8 Figure.
8 UT361/UT362 OPERA TING MANUAL Display Symbols (see figure 2) Figure 2.
9 UT361/UT362 OPERA TING MANUAL Functional Signs Below table indicated for information about the functional sign operations. Number 1 2 3 4 5 6 7 8 9 Sign MAX MIN A VE READ REC NO.
10 UT361/UT362 OPERA TING MANUAL Number 10 1 1 12 13 14 15 16 17 18 Meaning Secondary Data Display Primary Data Display Wind Speed Unit - Foot Per Minute Wind Speed Unit - Meter Per Second Fahrenheit .
1 1 UT361/UT362 OPERA TING MANUAL Display Symbols (see figure 3) Figure 3 Function Key Description Power on / Power off Button Button 1 - This button function key switch is for wind speed measurement and wind count measurement. During wind speed measurement, press "UNIT" button m/s ft/min KNOTS Km/h MPH and vice versa.
UT361/UT362 OPERA TING MANUAL 12 Button 5 - Display the data download to USB port (For UT362 only) Description Button 2 - Press this button to choose In wind speed measurement: maximum reading, minimu.
13 UT361/UT362 OPERA TING MANUAL Function Key Description Button 7 - Press this button to activate the REC feature. Press and Hold this button to access data reading from database Button 8 - Press this button to erase the data records before power on.
14 UT361/UT362 OPERA TING MANUAL Setup up the Anemoscopes Press and hold button 9 (menu) to select feature setup. Press next button to go next feature sub-menu. A. USB setup Press button 8 from USBO USB1. Then set up is as the opening default B. Auto Switch Down Press button 8 from AP00 AP01 and store in after power off.
15 UT361/UT362 OPERA TING MANUAL This default keep it and no need to reset when power on. D. Master Reset LCD shows the DEF with flash. Y ou can reset your anemoscopes to the factory settings. Press button 2 of to the factory settings for USBO, APO1, 60S data clearing.
16 UT361/UT362 OPERA TING MANUAL Using the Anemoscopes Power On: Press "Power " button for a while to switch the anemoscopes on Wind Speed and Wind Count Feature Switch: Press VEL / FLOW button.
17 UT361/UT362 OPERA TING MANUAL Wind pipe input area: 1) Correct input the wind pipe area before wind count measurement 2) Set default area is one square meter after the entering wind count measurement. 3) Select the approiate wind count-measuring unit.
18 UT361/UT362 OPERA TING MANUAL Enter 1, ENTET Mean 1 LCD display " 1.000 " Enter 0, 0, 0, 1 Mean 0001 LCD display " 1.000 " Enter ., 0, 0, 1 Mean . 001 LCD display " 0.001 " ... ... ... In one area, it will probably to have a different input methods but finally it has one display: Data Input Range: 0.
19 UT361/UT362 OPERA TING MANUAL Data Storage Functions: 1) LCD display " No Data " if no data storage 2) LCD display " T ime " if database is full and cannot store any data in the current time. 3) Manual data storage: press button 7 to display the automatic data storage in LCD, also LCD displays REC and around 0.
20 UT361/UT362 OPERA TING MANUAL 5) Record Clearing Method 1: Press and hold button 8 until LCD appear CLR when power on. Method 2: Resume to factory setting (see function setting stuff) Press and hold button 7 to view the data records of wind speed measurement and wind count measurement.
Screw Wind Figure 4 Measuring For Wind Speed (Wind Count) (see figure 4) Note: before use, the wind speed is over 10m/s under 1 - 2 minutes duration. T o carry out anemoscopes, follow the following procedure: 1. Press on " Power " button until the anemoscopes on 2.
22 UT361/UT362 OPERA TING MANUAL 4. Use figure 4 to conduct wind speed measurement , it shows wind flow direction, but bear in mind W arning do not use it in opposite. A screw can fix on it. (Note: UNI-T will not provide this screw to the customer , the customer need to buy it separately) 5.
23 UT361/UT362 OPERA TING MANUAL Computer Connectivity (For UT362 only)(see figure 5) When use the anemoscopes model UT362 need to connect USB cable with the computer Connect the USB interface cable, .
24 UT361/UT362 OPERA TING MANUAL Maintenance A. Replacing The Battery T o avoid false reading, which could read to possible electronic shock or personal injury , replace the battery as soon as the battery indicator " " appears.
25 UT361/UT362 OPERA TING MANUAL 5) Rejoin the case bottom and the battery compartment and reinstall the screw . B. Cleaning Periodically wipe the case with a damp cloth and mild detergent. Do not use abrasives or solvents. C. Service And Repairing This anemoscope is an auto calibration.
26 UT361/UT362 OPERA TING MANUAL 2) T ake out the battery when it is not using for a long time. 3) Do not use or store the Meter in a place of humidity , high temperature, explosive, inflammable and strong magnetic field.
27 UT361/UT362 OPERA TING MANUAL Range 2~10 m/s 10~30 m/s UT362 (3%+0.5) (3%+0.8) UT361 (3%+0.5) (3%+0.8) Accuracy T echnical Specification Wind Speed Measurement.
28 UT361/UT362 OPERA TING MANUAL T emperature Measurement T emperature Main Unit T emperature Sensor T emperature Range 0 ~40 32 ~ 104 0 ~40 32 ~ 104 UT362 3 4 3 4 UT361 3 4 3 4 Accuracy ** END **.
29 UT361/UT362 OPERA TING MANUAL This operating manual is subject to change without notice..
30 UT361/UT362 OPERA TING MANUAL.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Uni-T UT362 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Uni-T UT362 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Uni-T UT362 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Uni-T UT362 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Uni-T UT362, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Uni-T UT362.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Uni-T UT362. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Uni-T UT362 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.