T urbo air Speeds Up the P ace of Inno vation Refrigerator Freezer Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment! <Soli.
1. SPECIFICATION .......................................................................................... 2 2. SERIAL NUMBER ........................................................................................ 2 3. INSTALLATION .................
3 Turbo air 1. GOOD AIR CIRCULA TION - Be sure to avoid any partition and object which may stop the air flow. - Be sure that air space is allowed to flow the rear of the unit. Turbo air recommends that the rear of the unit would be no less than 5 inches from the wall.
4 Turbo air CLEANING 1. CLEANING ST AINLESS STEEL INTERIOR AND EXTERIOR (select models) : Damage to stainless steel finish due to improper use of cleaning products or non- recommended products is NOT covered under this product's warranty.
5 Turbo air B ASIC OPERA TION MSR-23NM MSR-23G-1 MSR-49NM MSR-49G-2 MSR-72G-3 1. Plug in and turn on the power switch located on the bottom of the top grille right side. The Display panel will be lighted and make a beep sound. The compressor will begin to run.
6 Turbo air DISPLA Y P ANEL OF REFRIGERA T OR 9 TEMPERA TURE Q .C. 8 7 6 5 4 3 2 1 FA N DOOR QUICK COOLING TEMPERA TURE ˚F TEMP . SETTING QUICK COOLING F AN RUNNING DOOR OPENING QUICK COOLING BUTTON TEMP . CONTROL BUTTON (SEE T O P AGE 7) INNER TEMP .
7 Turbo air 1. If you push the Q.C. (QUICK Cooling) button, the compressor will run continuously until D-Senser detect 14 ˚ F (-10 ˚ C) to bring down the temperature more quickly. (max.comp.run time = 120 min.) 2. If you push the Q.C. button again during QUICK Cooling mode, the compressor will return to the normal operation.
8 Turbo air 1. It displays the inside temperature. 2. Display range is 14 ˚ F to 69 ˚ F (-10 ˚ C ~ +20 ˚ C). 3. When the inside temperature is lower than 14 ˚ F, the panel will display ‘ ’. and, higher than 69 ˚ F, the panel will display ‘ ’.
9 Turbo air B ASIC OPERA TION 1. Plug in and turn on the power switch located on the bottom of the top grille right side. The Display panel will be lighted and make a beep sound. The compressor will begin to run. 2. The default temperature setting is No.
10 Turbo air DISPLA Y P ANEL OF FREEZER 9 TEMPERA TURE D.F . 8 7 6 5 4 3 2 1 FA N DOOR MANU AL DEFROST TEMPERA TURE ˚F TEMP . SETTING MANUAL DEFROST F AN RUNNING DOOR OPENING MANUAL DEFROST BUTTON TEMP . CONTROL BUTTON (SEE T O P AGE 1 1) INNER TEMP .
11 Turbo air 1. If you push MANUAL DEFROST button for 5 seconds, the Defrost will start. 2. During the Manual Defrost mode, the Up/Down button for the temperature control can not make the compressor cycle ON or OFF. 3. If you want to change the Manual Defrost mode to the normal mode, push MANUAL DEFROST button for 5 seconds.
12 Turbo air 1. It displays inside temperature. 2. Display range is -50 ˚ F to 50 ˚ F (-45 ˚ C ~ +10 ˚ C). 3. When inside temperature is lower than -50 ˚ F, the panel will display ‘ ’. and, higher than +50 ˚ F, the panel will show ‘ ’. 1.
13 Turbo air BEFORE REQUESTING SER VICE SYMPT OMS CA USES SOLUTIONS Freezer is melting f ood. The unit does not refrigerate at all. The unit does not refrigerate well. There is a loud noise. There are dew-dr ops on the unit exterior . There are dew-dr ops on the unit interior .
14 Turbo air MANUF A CTURING COMP ANY Turbo air warrants to the original purchaser of every new-Turbo air refrigerated unit, the cabinet and all parts thereof, to be free from defects in material or w.
15 Turbo air WHA T IS NO T CO VERED BY THIS W ARRANTY Turbo air’s obligation under warranty is limited to either repair or replacement of parts, subject to the additional limitation s below. This warranty neither assumes nor authorizes any person to assume obligations other than expressly covered by this warranty.
Warranty Claims... All claims for parts or labor must be made directly thorough Turbo Air. All claims should include: model number of the unit, the serial number of the cabinet, proof of purchase, date of installation, and all pertinent information supporting the alleged defect.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Turbo Air MSR-72G-3 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Turbo Air MSR-72G-3 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Turbo Air MSR-72G-3 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Turbo Air MSR-72G-3 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Turbo Air MSR-72G-3, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Turbo Air MSR-72G-3.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Turbo Air MSR-72G-3. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Turbo Air MSR-72G-3 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.