............ www .truemfg.com ............ INST ALLA TION MANUAL FOR TCGR DISPLA Y CASES (REFRIGERA TED BAKER Y & COLD DELI) MODELS CUR VED GLASS DISPLA Y CASES - REFRIGERA TED BAKER Y & COLD DELI - CONGRA TULA TIONS! Y ou have just purchased the finest commercial refrigeration available.
.
............ www .truemfg.com ............ T rue Food Service Equipment, Inc. 1 1 SAFETY INFORMA TION • This display case must be pr operly installed and located in accordance with the Installation Instructions before it is used. • Do not allow childr en to climb, stand or hang on the shelves in the displa y case.
............ www .truemfg.com ............ T rue Food Service Equipment, Inc. 2 2 SAFETY INFORMA TION PROPER DISPOSAL OF THE DISPLA Y CASE DANGER! RISK OF CHILD ENTRAPMENT USE OF EXTENSION CORDS NEVER USE AN EXTENSION CORD! TRUE will not warranty any display case that has been connected to an extension cord.
............ www .truemfg.com ............ T rue Food Service Equipment, Inc. 3 3 Bef ore your ne w display case is connected to a power suppl y , chec k the incoming voltag e with a voltmeter . If anything less than 100% of the rated voltag e f or operation is noted, correct immediately .
............ www .truemfg.com ............ T rue Food Service Equipment, Inc. 4 4 INST ALLA TION / OPERA TION INSTRUCTIONS T o insure that your unit wor ks properl y from the first day , it must be installed properly . W e highly recommend a trained mec hanic and electrician install your T r ue equipment.
............ www .truemfg.com ............ T rue Food Service Equipment, Inc. 5 5 INST ALLA TION / OPERA TION INSTRUCTIONS TOOLS REQUIRED: • Phillips screw driver • 3 / 8 ” (9.
............ www .truemfg.com ............ T rue Food Service Equipment, Inc. 6 6 INST ALLA TION / OPERA TION INSTRUCTIONS Step 4 NOTE Hard wiring for a 30 amp circuit is required on specific Bakery Cases. A. Before y our new unit is connected to a po wer supply , check the incoming v oltage with a voltmeter .
............ www .truemfg.com ............ T rue Food Service Equipment, Inc. 7 7 INST ALLA TION / OPERA TION INSTRUCTIONS CONDUCTORS AND CIRCUITS Wire Gauge for 2% Voltage Drop in Supply Circuits.
............ www .truemfg.com ............ T rue Food Service Equipment, Inc. 8 8 Step 5 A. The compressor is r eady to oper ate. Plug in the display case. B. Check the temperature control setting in the lower right of the cabinet backside. The setting should be at No.
............ www .truemfg.com ............ T rue Food Service Equipment, Inc. 9 9 INST ALLA TION / OPERA TION INSTRUCTIONS SHEL VING INST ALLA TION (REFRIGERA TED BAKERY) SHELF INST ALLA TION: A. Lift each door up and out of track (do not dis- connect elastic tubing).
............ www .truemfg.com ............ T rue Food Service Equipment, Inc. 10 10 INST ALLA TION / OPERA TION INSTRUCTIONS SHEL VING INST ALLA TION (COLD DELI) SHELF INST ALLA TION: A. Lift each door up and out of track (do not dis- connect elastic tubing).
............ www .truemfg.com ............ T rue Food Service Equipment, Inc. 11 11 INST ALLA TION / OPERA TION INSTRUCTIONS OPTIONAL (INST ALLING OPTIONAL CASTORS) CASTOR INST ALLA TION: TOOLS REQUIRED: • Castor wrenc h (if not included contact T r ue) • Adjustable wrenc h NOTE Castors not available for hard wired or remote models.
............ www .truemfg.com ............ T rue Food Service Equipment, Inc. 12 12 INST ALLA TION / OPERA TION INSTRUCTIONS FORMICA KIT INST ALLA TION: FORMICA KIT COMPONENTS: (2) F or mica T op End P anels 10 3 / 4 "w x 33"h (27.3 cm x 83.
............ www .truemfg.com ............ T rue Food Service Equipment, Inc. 13 13 MAINTENANCE, CARE & CLEANING • The e xterior may be wiped clean with mild soap and water . The use of stainless steel cleaners or other such solv ents is not recommended on plastic parts.
............ www .truemfg.com ............ T rue Food Service Equipment, Inc. 14 14 MAINTENANCE, CARE & CLEANING LIGHT BULB REPLACEMENT SHELF MOUNTED BULB REPLACEMENT : WARNING When replacing a light bulb make sure power to the unit is either turned off or unplugged.
............ www .truemfg.com ............ T rue Food Service Equipment, Inc. 15 15 MAINTENANCE, CARE & CLEANING TEMPERA TURE CONTROL ADJUSTMENT FOR HIGH AL TITUDE ONL Y! TERMS: • Cut-out - T emperature sensed by the controller that shuts the compressor off.
............ www .truemfg.com ............ T rue Food Service Equipment, Inc. 16 16 CLEANING THE CONDENSER COIL When using electrical appliances, basic safety precautions should be followed, including the following CONDENSER CLEANING: TOOLS REQUIRED: • Phillips scre wdriver • Stiff br istle brush • Adjustable wrench • V acuum A.
............ www .truemfg.com ............ T rue Food Service Equipment, Inc. 17 17 Condensers accumulate dirt and require cleaning every 30 days. Dirty condensers result in compressor failure, product loss, and lost sales... which are not covered by warranty .
............ www .truemfg.com ............ T rue Food Service Equipment, Inc. 18 18 CAUTION: Do not use any steel wool, abrasive or chlorine based products to clean stainless steel surfaces.
............ www .truemfg.com ............ T rue Food Service Equipment, Inc. 19 19 Recommended cleaners f or cer tain situations / environments of stainless steel A) Soap, ammonia and detergent medallion applied with a cloth or spong e can be used for routine cleaning.
............ www .truemfg.com ............ T rue Food Service Equipment, Inc. 20 20 W ARRANTY INFORMA TION (U.S.A. and Canada ONL Y!) ONE YEAR P ARTS & LABOR W ARRANTY TRUE warrants to the origina.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il True Manufacturing Company TCGR-50-CD è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del True Manufacturing Company TCGR-50-CD - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso True Manufacturing Company TCGR-50-CD imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul True Manufacturing Company TCGR-50-CD ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il True Manufacturing Company TCGR-50-CD, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del True Manufacturing Company TCGR-50-CD.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il True Manufacturing Company TCGR-50-CD. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo True Manufacturing Company TCGR-50-CD insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.